Plan Review Details - Permit 10080787
| Plan Review Stops For Permit 10080787 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2010-12-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-12-20 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-12-20 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2010-12-20 17:01:53 | ****PROVISO**** | | | ***PROVIDE AT INSPECTION*** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. FROM FIRST CORRECTION LIST: EITHER PROVIDE A WINDOW | | | SCHEDULE OR REVISE THE FLOOR PLAN TO SHOW THE WINDOW | | | SIZES, FBC1609. | | | | | | DOCUMENT SUBMITTED SHOWS WINDOW SIZE FOR OPENINGS 4, 1, | | | AND 2. EITHER REVISE THE FLOOR PLAN OR PROVIDE A WINDOW | | | SCHEDULE TO SHOW WINDOW SIZES FOR OPENINGS 3, 5, 6, 7. | | | | | | PER CONTRACTOR, ALL WINDOWS ARE SMALLER THAN MAX SIZE | | | ALLOWED PER PRODUCT APPROVAL. REVISED FLOOR PLAN TO BE | | | PROVIDED AT INSPECTION. | | | | | | 2. ENGINEERING SHOW A MULLION, LOCATION UNCLEAR BASED | | | ON DOCUMENTS PROVIDED. INCLUDE IN THE WINDOW SCHEDULE | | | (OR REVISED FLOOR PLAN). | | | | | | PER CONTRACTOR, LOCATION WILL BE INDICATED ON FLOOR | | | PLAN AND PROVIDED AT INSPECTION. | | | | | | 3. ENGINEER IS TO REVISE ENGINEERING TO INCLUDE THE | | | FOLLOWING INFORMATION: | | | LOCATION SPECIFIC TO THE UNIT REGARDING PROPOSED | | | INSSTALLATION | | | THIRD PAGE OF ENGINEERING REFERS TO ADJUSTMENT FACTOR | | | FOR 15' HEIGHT, REVISE OR PROVIDE EXPLANATION (ISN'T | | | THIS A 4 STORY BUILDING?) | | | | | | PER ENGINEER, DISREGARD 3RD PAGE (NOTES FOR FILE ONLY, | | | NOT INTENDED FOR PLAN REVIEW. DESIGN PRESSURES WERE | | | CALCULATED CORRECTLY USING CORRECT BUILDING HEIGHT. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-10-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-10-01 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-10-01 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2010-10-01 11:37:29 | ****PROVISO**** | | | ****REVISION REQUIRED**** | | | ****ISSUED AT CONTRACTOR'S RISK**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. FROM FIRST CORRECTION LIST: EITHER PROVIDE A WINDOW | | | SCHEDULE OR REVISE THE FLOOR PLAN TO SHOW THE WINDOW | | | SIZES, FBC1609. | | | | | | DOCUMENT SUBMITTED SHOWS WINDOW SIZE FOR OPENINGS 4, 1, | | | AND 2. EITHER REVISE THE FLOOR PLAN OR PROVIDE A WINDOW | | | SCHEDULE TO SHOW WINDOW SIZES FOR OPENINGS 3, 5, 6, 7. | | | | | | 2. ENGINEERING SHOW A MULLION, LOCATION UNCLEAR BASED | | | ON DOCUMENTS PROVIDED. INCLUDE IN THE WINDOW SCHEDULE | | | (OR REVISED FLOOR PLAN). | | | | | | 3. ENGINEER IS TO REVISE ENGINEERING TO INCLUDE THE | | | FOLLOWING INFORMATION: | | | LOCATION SPECIFIC TO THE UNIT REGARDING PROPOSED | | | INSSTALLATION | | | THIRD PAGE OF ENGINEERING REFERS TO ADJUSTMENT FACTOR | | | FOR 15' HEIGHT, REVISE OR PROVIDE EXPLANATION (ISN'T | | | THIS A 4 STORY BUILDING?) | | | | | | | | | | | | 3. WITH THE REVISION, PROVIDE A COPY OF THE CONTRACT | | | FOR THIS JOB. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-09-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-09-08 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-09-08 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2010-09-08 08:29:30 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. THE PRODUCT APPROVALS SUBMITTED ARE ALREADY STAMPED | | | FOR ANOTHER JOB (PERMIT NUMBER STAMP, DATE STAMP). | | | PROVIDE CLEAN PRODUCT APPROVALS, SEE | | | WWW.FLORIDABUILDING.ORG OR WWW.MIAMIDADE.GOV, FBC106. | | | | | | 2. EITHER PROVIDE A WINDOW SCHEDULE OR REVISE THE FLOOR | | | PLAN TO SHOW THE WINDOW SIZES, FBC1609. | | | | | | 2. THE QUALIFIER IS REQUIRED TO SIGN THE PERMIT | | | APPLICATION. PLEASE PRINT THE ENTIRE NAME OF THE | | | INDIVIDUAL SIGNING THE DOCUMENT. THE PERMIT APPLICATION | | | WAS SIGNED BY "DP MCMULLEN AS PRESIDENT" SO DOES NOT | | | APPEAR TO BE SIGNED BY THE QUALIFIER DANNY MCMULLEN. | | | THIS COMPANY DOES NOT HAVE ANY AUTHORIZED AGENTS ON | | | FILE WITH THE CITY OF WEST PALM BEACH. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-09-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-09-27 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-09-27 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2010-09-27 10:19:03 | SENT TO S. HILL'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-09-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-09-08 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-08-31 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2010-08-31 12:20:39 | UNDER 5 K BUILDING |
|
|
|