Plan Review Details - Permit 10080635
| Plan Review Stops For Permit 10080635 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
10:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-10-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-10-01 |
Time |
10:47 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2010-10-01 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2010-10-01 10:57:45 | BUILDING PLAN REVIEW | | | PERMIT: 10080635 | | | ADD: 8085 IRONHORSE BLVD | | | CONT: GLOBE TEC CONSTRUCTION | | | | | | TEL: (954)214-3759 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PLANS FAIL TO PROVIDE HOW THE GENERATOR WILL COMPLY | | | WITH FBC-B 1604.4 EVERY STRUCTURE SHALL BE DESIGNED TO | | | RESIST OVERTURNING EFFECTS CAUSED BY TTHE LATERAL | | | FORCES SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR | | | WIND. SHEET E-5 NOTE 5. | | | | | | 2) SHEET E-5 INDICATES A DOUBLE WALL STEEL BASE TANK, | | | PLEASE PROVIDE MANUFACTURERS SPEC ON THIS TANK. | | | | | | BUILDING PLAN REVIEW | | | PERMIT: | | | ADD: | | | CONT: | | | TEL: (561)###-#### | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | REVIEW | | | ACTION: DENIED |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2010-09-30 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2010-09-30 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2010-09-30 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2010-09-30 13:23:38 | 8085 IRONHORSE BOULEVARD | | | PERMIT NUMBER 10080635 | | | | | | | | | ON SEPTEMBER 30, 2010, THIS WRITER SPOKE TO JONATHAN | | | BRAMLEY, DIRECTOR OF ENGINEERING SERVICES. WE DISCUSSED | | | THE PLANS AND IT APPEARS THAT ONE SET OF PLANS EXIST | | | FOR TWO LOCATIONS. | | | | | | PREVIOUS PLAN REVIEW COMMENTS APPEAR TO BE ADDRESSED ON | | | THE PLANS. | | | | | | MIKE CARSILLO, BATTALION CHIEF | | | BUREAU OF FIRE PREVENTION |
|
|
| Review Stop |
FUEL |
DIESEL GENERATOR |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-12-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-12-09 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-09-22 |
Time |
07:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2010-10-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-10-26 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-10-26 |
Time |
16:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2010-10-26 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2010-10-26 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2010-10-26 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2010-10-26 13:27:22 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | SCREENING FOR THE GENERATOR MUST BE PROVIDED THAT IS | | | COMPATIBLE WITH THE SURROUNDING ARCHITECTURE. PLEASE | | | SUBMIT PLAMS AND ELEVATIONS FOR THE REQUIRED SCREENING. | | | | | | PLEASE SUBMIT A SURVEY OF THE PROPERTY WITH THE | | | LOCATION OF THE MECHANICAL EQUIPMENT CLEARY INDICATED. | | | THE SITE PLAN SUGGEST THAT MECHANICAL EQUIPMENT MAY BE | | | ENCROACHING ONTO THE NEIGHBORING PROPERTY. |
|
|
|