| Plan Review Stops For Permit 10080045 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-10-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-10-07 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-10-06 |
Time |
07:32 |
Sent To |
|
|
| Notes |
| 2010-10-06 07:33:11 | ****PROVISOS**** | | | ****REVISION REQUIRED**** | | | ****ISSUED AT CONTRACTOR'S RISK**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. CITY OF WEST PALM BEACH MUNICIPAL CODE 94-546(B), | | | FIRST FLOOR TOP OF SLAB TO BE ELEVATED TO 7.5' NGVD | | | WITH CONCRETE PER DISCUSSIONS WITH ARCHITECT, PROPOSED | | | DETAIL DATED 9-21-10, AND ARCHITECT'S STATEMENT | | | REGARDING FLOOD RESISTANCE. REVISE SHEET A1, A2, AND | | | ANY OTHER AFFECTED SHEETS. | | | | | | 2. FAC9B72, PRODUCT APPROVALS REVIEWED BY DESIGNER OF | | | RECORD REQUIRED FOR ALL COMPONENTS AND CLADDING AND | | | STRUCTURAL COMPONENTS SUCH AS THE ROOF, SIDING, FRONT | | | DOOR, GARAGE DOOR, HELICAL PIERS. THE ROOF PRODUCT | | | APPROVAL MAY BE SUBMITTED WITH THE ROOF PERMIT AND WILL | | | REQUIRE REVIEW AT THAT TIME. OTHER PRODUCT APPROVALS | | | NOT INCLUDED IN THIS SUBMITTAL ARE TO BE SUBMITTED AS A | | | REVISION PRIOR TO INSTALLATION. | | | | | | 3. PRIOR TO INSTALLATION, INVESTIGATE AND ADDRESS ANY | | | POTENTIAL ISSUES WHICH MAY ARISE FROM DISSIMILAR METALS | | | ON THE ROOF (METAL ROOF, COPPER FLASHING, ALUMINUM | | | GUTTERS), R904.2. | | | | | | 4. SHEET A8, STUCCO TO BE < 5/8" OR ALLOW 6" FOR | | | INSPECTION FOR TERMITES, FBC R704.1. | | | | | | 5. PROVIDE ORIGINAL SIGNED, SEALED SOILS INVESTIGATION | | | REPORT AT INSPECTION. | | | | | | 6. ENGINEER TO PROVIDE A LETTER OR REVISE THE PLAN TO | | | CONFIRM THAT THE DESIGN CONFORMS TO THE REQUIREMENT OF | | | FBC R301.2.1.4.3(2), "ROOF SHEATHING UPLIFT AND | | | ROOF-TO-WALL UPLIFT LOADS SHALL BE INCREASED BY 20 | | | PERCENT." | | | | | | 7. SUBMIT A REVISED, CORRECTED ELEVATION CERTIFICATE | | | (DISCUSSED WITH CHRIS, COMPASS SURVEYING). THE REVISED | | | "CONSTRUCTION DRAWINGS" ELEVATION CERTIFICATE IS TO BE | | | SUBMITTED WITH THE REVISION PRIOR TO CONCRETE POUR. | | | | | | 8. MECHANICAL PLANS REQUIRED WITH SUBMISSION OF | | | MECHANICAL PERMIT. MECHANICAL PLANS TO INCLUDE PROPOSED | | | ELEVATION OF NEW AND EXISTING EQUIPMENT. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-08-17 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-08-17 |
Time |
18:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-08-13 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2010-08-17 19:26:49 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. ARCHITECTURAL SHEET A3 DOES NOT MATCH MECHANICAL | | | FLOOR PLAN, SEE MASTER BEDROOM. | | | | | | 2. PROVIDE THE TOTAL SQUARE FOOT AREA UNDER AIR | | | PROPOSED. IMPACT FEES MAY BE DUE TO PALM BEACH COUNTY, | | | 233-5025. THE PLANS ARE TO BE STAMPED AND THE RECEIPT | | | (IF FEES ARE DUE) PROVIDED. | | | | | | 3. THIS PARCEL IS LOCATED IN A FLOOD ZONE. FINISHED | | | FLOOR IS REQUIRED TO BE 6" ABOVE BFE (WPB ADMIN CODE | | | 94-546(B)*. | | | | | | 4. PROVIDE A SIGNED AND SEALED FLOOD ELEVATION | | | CERTIFICATE FOR THE PROPOSED CONSTRUCTION | | | (HTTP://WWW.FEMA.GOV/BUSINESS/NFIP/ELVINST.SHTM). THREE | | | ELEVATION CERTIFICATES WILL REQUIRED; PRE CONSTRUCTION, | | | FORM BOARD, AND FINISHED FLOOR. | | | | | | 5. PROVIDE A COST BREAKDOWN OF THE PROPOSED | | | IMPROVEMENT. AS PROPOSED ELEVATIONS WERE NOT PROVIDED, | | | AND A COST BREAKDOWN (ADDITION VS. RENOVATION AREAS) IT | | | IS NOT CLEAR WHETHER OR NOT THIS IS A SUBSTANTIAL | | | IMPROVEMENT, WPB ADMIN CODE 94-546. SEE ALSO HTTP://WWW | | | .FEMA.GOV/PLAN/PREVENT/FLOODPLAIN/NFIPKEYWORDS/SI.SHTM | | | FOR MORE INFORMATION. | | | | | | 6. SEE FBC EXISTING BUILDING 401.4, A DESIGN | | | PROFESSIONAL OR AN OWNER MUST ELECT ONE OR A | | | COMBINATION OF LEVELS OF ALTERATION. PLEASE INCLUDE | | | THIS INFORMATION ON THE PLAN. PLEASE REVIEW ALL | | | REQUIREMENTS (AND ALSO CH 10, ADDITIONS) AND SHOW | | | COMPLIANCE ON THE PLAN. | | | | | | 7. PROVIDE A COPY OF THE SURVEY FOR THIS PARCEL. | | | | | | 8. PRODUCT APPROVAL REQUIRED FOR THE SIDING AND ROOF. | | | THE ROOF PRODUCT APPROVAL MAY BE SUBMITTED WITH THE | | | ROOF PERMIT. | | | | | | 9. STUCCO IS SHOWN AS 5/8" ON SHEET A8, SEE INSPECTION | | | FOR TERMITES 704.1 EXCEPTION 1. | | | | | | 10. PROVIDE ENERGY CALCS, FBC 13-6. | | | | | | 11. SMOKE AND CARBON MONOXIDE ALARMS ARE REFERENCED ON | | | E3 BUT NOT SHOWN ON PLAN, PLEASE SHOW ALL REQUIRED ON | | | THE PLAN. | | | | | | 12. SEE FS 553.844 REGARDING ROOF MITIGATION | | | REQUIREMENTS AND OPENING PROTECTION REQUIREMENTS AND | | | SHOW COMPLIANCE ON THE PLAN. CLARIFY SCOPE OF REROOF | | | AREA. | | | | | | 13. SEE FBC R301.2.1.4.3 (2), EXPOSURE C: BUILDINGS | | | LOCATED WITHIN A DISTANCE OF 600 FEET OF INLAND BODIES | | | OF WATER THAT PRESENT A FETCH OF 1 MILE (1.61 KM) OR | | | MORE OR INLAND WATERWAYS OR RIVERS WITH A WIDTH OF 1 | | | MILE (1.61 KM) OR MORE SHALL BE CLASSIFIED AS EXPOSURE | | | C AND ROOF SHEATHING UPLIFT AND ROOF-TO-WALL UPLIFT | | | LOADS SHALL BE INCREASED BY 20 PERCENT. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2010-10-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-09-21 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-09-21 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2010-10-07 16:29:28 | RESTAMP | | | | | 2010-10-07 10:20:50 | OK PER JOHN DICKINSON CONTRACT REVIEWER | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-08-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-08-13 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-08-13 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2010-08-13 08:54:10 | OK PER JOHN DICKINSON (CONTRACT REVIEWER) PX3182 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2010-10-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-10-07 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-10-07 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2010-10-07 13:37:07 | TO SH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-09-10 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-09-10 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-09-10 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2010-09-10 10:27:09 | *****************EXPEDITED*****************2ND RUN | | | R--19 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-08-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-08-17 |
Time |
19:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-08-04 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2010-08-04 12:34:15 | **************EXPEDITED***************** | | | R-13 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2010-10-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-10-07 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-10-07 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2010-10-07 13:37:26 | PLANS STAMPED, NO FEES DUE | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2010-10-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-10-06 |
Time |
07:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-10-06 |
Time |
07:33 |
Sent To |
|
|
| Notes |
| 2010-10-06 07:35:26 | IMPACT FEE ASSESSMENT (PERFORMED BY PALM BEACH COUNTY) | | | REQUIRED, 233-5025 FOR MORE INFORMATION. THE STAMPED | | | PLANS AND THE RECEIPT SHOWING THAT ASSESSED FEES HAVE | | | BEEN PAID (IF APPLICABLE) TO BE RETURNED TO THIS | | | OFFICE. | | | | | | | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2010-08-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-08-17 |
Time |
19:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-08-17 |
Time |
19:41 |
Sent To |
|
|
| Notes |
| 2010-08-17 19:41:52 | SEE BLDG REVIEW |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
N |
Date |
2010-10-07 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2010-10-07 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2010-10-07 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2010-10-07 16:43:43 | ***LANDSCAPE REVIEW NOT REQUIRED *** | | | | | | PLEASE REFER TO PERMIT #10100151 FOR LANDSCAPE PERMIT | | | AND PLANS. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2010-10-01 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2010-10-01 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2010-10-01 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2010-10-01 08:47:35 | ***LANDSCAPE REVIEW FAILED*** | | | | | | PLEASE RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT. | | | | | | 1. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF | | | THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE | | | (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | | THE ZLDR. | | | | | | 2. PLEASE SUBMIT A LANDSCAPE PERMIT APPLICATION AND TWO | | | (2) COPIES OF A LANDSCAPE PLAN SHOWING COMPLIANCE WITH | | | SECTIONS 94-442 AND 94-445 OF THE ZLDR. | | | | | | 3. PLEASE PROVIDE THE TABULATION NECESSARY FOR THE | | | EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING | | | AND LAND DEVELOPMENT REGULATIONS, INCLUDING THE | | | XERISCAPE DESIGN OPTIONS. | | | | | | 4. PURSUANT TO SECTION 94-448 (D) (2), ALL OF THE ITEMS | | | ENUMERATED IN THIS SECTION SHALL BE INCLUDED IN THE | | | LANDSCAPE PLAN. | | | | | | 5. A SEPARATE IRRIGATION PERMIT IS REQUIRED. PLEASE | | | SUBMIT AN IRRIGATION APPLICATION AND TWO (2) SETS OF | | | PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2010-11-08 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-11-08 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-11-08 |
Time |
13:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2010-10-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-10-07 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-10-07 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2010-10-07 09:25:39 | MECHANICAL PLANS REQUIRED WITH SUBMISSION OF MECHANICAL | | | PERMIT. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2010-08-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-08-13 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-08-13 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2010-08-13 16:28:53 | ****CORRECTIONS**** | | | | | | 1. MECHANICAL PLAN DOES NOT PROVIDE INFORMATION SUCH AS | | | DUCT LAYOUT, SIZE, NEW WORK, EXISTING, RETURNS, | | | EQUIPMENT, ETC. PROVIDE A COMPLETE MECHANICAL PLAN FOR | | | REVIEW. | | | | | | 2. NEW UNDER AIR SQUARE FOOTAGE SHOWN. INFORMATION | | | REGARDING HOW THIS AREA WILL BE CONDITIONED (DUCTWORK, | | | INFO REGARDING EXISTING UNIT, NEW SQUARE FOOT AREA, | | | ETC.) TO BE PROVIDED. SHOW HOW IT HAS BEEN DETERMINED | | | THAT THE EXISTING UNIT CAN ACCOMODATE THE NEW UNDER AIR | | | SQUARE FOOTAGE. | | | | | | 3. MECHANICAL SHEETS DO NOT MATCH ARCHITECTURALS. FOR | | | INSTANCE, SEE MASTER BEDROOM, MASTER BATH, WARDROBE - | | | COMPARE SHEETS A3, M1.02. | | | | | | 4. ENERGY CALCS REQUIRED FOR ADDITIONAL SQUARE FOOT | | | AREA, FBC 13-101. | | | | | | HAROLD MOSER, 805-6732 | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2010-10-01 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-10-01 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-10-01 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2010-10-01 15:11:51 | *****PROVISO***** | | | DRIP DRY WILL REQUIRE WATER SUPPLIED OR | | | A TRAP PRIMER | | | 1002.4 TRAP SEALS. ....WHERE A TRAP SEAL IS | | | SUBJECT TO LOSS BY EVAPORATION, A TRAP SEAL | | | PRIMER VALVE SHALL BE INSTALLED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2010-08-12 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-08-12 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-08-12 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2010-08-12 12:58:35 | *****PROVISO***** | | | DRIP DRY WILL REQUIRE WATER SUPPLIED OR | | | A TRAP PRIMER | | | 1002.4 TRAP SEALS. ....WHERE A TRAP SEAL IS | | | SUBJECT TO LOSS BY EVAPORATION, A TRAP SEAL | | | PRIMER VALVE SHALL BE INSTALLED. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2010-09-30 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2010-09-30 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2010-09-30 |
Time |
10:00 |
Sent To |
L |
|
| Notes |
| 2010-09-30 10:01:32 | AMY STELLY | | | PLANNING AND ZONING | | | 822-1442 | | | | | | SENT TO LANDSCAPING FOR REVIEW |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2010-08-17 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2010-08-17 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2010-08-17 |
Time |
09:14 |
Sent To |
B |
|
| Notes |
| 2010-08-17 09:23:04 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | PERMIT RECORDS INDICATE THAT THE VALUE OF THE | | | IMPROVEMENTS TO PROPERTY DURING THE LAST YEAR EXCEED | | | 50% OF THE VALUE OF THE STRUCTURE. CONSEQUENTLY, A | | | LANDSCAPE PLAN MUST BE SUBMITTED FOR REVIEW. PLEASE | | | NOTE THAT YOUR RESUBMISSION MAY GENERATE ADDITIONAL | | | COMMENTS. |
|
|