Plan Review Details - Permit 10070789
Plan Review Stops For Permit 10070789
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-09-27 Cont ID  
Sent By jgomez Date 2010-09-27 Time 16:00 Rev Time 0.00
Received By jgomez Date 2010-09-27 Time 14:07 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-08-17 Cont ID  
Sent By jgomez Date 2010-08-17 Time 14:58 Rev Time 0.00
Received By jgomez Date 2010-08-17 Time 14:58 Sent To  
Notes
2010-08-17 14:59:59RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW CHECKLIST.
 2007 FBC WITH 2009 REVISIONS.
  
 1- A) ENGINEER OF RECORD TO REVISE THE DESIGN CRITERIA.
 ACCORDING TO 2009 REVISIONS SEC. R301.2.1.4.3 OF THE
 2007 FLORIDA RESIDENTIAL CODE THIS HOUSE IS LOCATED ON
 EXPOSURE "C" NOT EXPOSURE "B". REVISE DESIGN EXPOSURE
 AS REQUIRED.
  
 B) REVISE THE OPENINGS DESIGN PRESSURES TO MATCH
 BUILDING EXPOSURE AS REQUIRED BY ITEM 1(A) ABOVE.
  
 2- A) PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED
 BY DCA RULE 9B-72 FOR THE TRUSS CONNECTORS SPECIFIED ON
 PLANS.
  
 B) ENGINEER OF RECORD TO REVIEW PRODUCT APPROVALS PRIOR
 TO SUBMITTAL. SEC. 106.3.3 CITY AMENDMENTS TO FBC.
  
 3- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUE.
 ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK
 UP.
  
 4- PLANS TO SPECIFY CARBON MONOXIDE ALARM AS REQUIRED
 BY SEC. R313.4 OF THE 2007 FLORIDA RESIDENTIAL CODE
 (2009 REVISIONS).
  
 5- EXISTING LANAI AREA WAS CHANGED TO GARAGE AREA.
 EXISTING BATHROOM WINDOW IS OPENING ONTO THE NEW GARAGE
 AREA. NEED TO PROVIDE OPENING PROTECTION AS REQUIRED BY
 SEC. R309.
  
 6- CLEARLY SPECIFY SIZE OF EGRESS WINDOW TO VERIFY
 COMPLIANCE WITH THE CLEAR WIDTH, HEIGHT AND TOTAL
 OPENING AREA AS REQUIRED BY SEC. R310.
  
 7- ACCORDION SHUTTERS INSTALLATION SCHEDULE:
  
 A) REVISE THE DESIGN PRESSURES. COORDINATE WITH ITEM
 #1(A) ABOVE.
  
 B) REVISE THE ANCHOR SPACING TO COORDINATE WITH THE
 REVISED DESIGN PRESSURES.
  
 C) CLEARLY MARK ON SHUTTERS DRAWINGS SPECIFIC ANCHOR
 TYPE AND SPACING TO VERIFY COMPLIANCE WITH THE THE
 REVISED DESIGN PRESSURES.
  
 D) EDGE DISTANCE ON SHUTTERS ANCHOR SCHEDULE IS BASED
 ON 3 1/2" EDGE DISTANCE. SEE SHEET 14 OF 28 OF SHUTTERS
 DRAWINGS. EDGE DISTANCE SHOWN ON THE INSTALLATION
 SCHEDULE SUBMITTED IS SHOWN AS 2". NEED TO REVISE THE
 ANCHOR SPACING AS REQUIRED BY EDGE DISTANCE TABLE ON
 SHEET 14 OF SHUTTERS DRAWING SUBMITTED.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-09-09 Cont ID  
Sent By dwise Date 2010-09-09 Time 15:40 Rev Time 0.00
Received By dwise Date 2010-09-09 Time 15:40 Sent To  
Notes
2010-09-09 15:40:52OK PER JOHN DICKINSON CONTRACT PLAN REVIEWER LICENSE
 NUMBER PX3182

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-08-25 Cont ID  
Sent By shill Date 2010-08-25 Time 06:10 Rev Time 0.00
Received By shill Date 2010-08-25 Time 06:10 Sent To  
Notes
2010-08-25 06:10:41OK PER JOHN DICKINSON (CONTRACT REVIEWER) PX3187
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-08-25 Cont ID  
Sent By lmartine Date 2010-08-25 Time 10:04 Rev Time 0.00
Received By lmartine Date 2010-08-25 Time 10:04 Sent To  
Notes
2010-09-13 09:38:049/13 ROUTED TO JG DESK
  
2010-09-07 14:30:119/7 ROUTED TO ELECTRIC
  
  
2010-08-25 10:04:31IN ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-07-29 Cont ID  
Sent By jwitmer Date 2010-07-29 Time 13:04 Rev Time 0.00
Received By jwitmer Date 2010-07-29 Time 13:04 Sent To  
Notes
2010-07-29 13:04:27INCOMING SEEENT TO R-11

Review Stop Z ZONING
Rev No 2 Status P Date 2010-09-03 Cont ID  
Sent By lfranco Date 2010-09-03 Time 16:47 Rev Time 0.00
Received By lfranco Date 2010-08-27 Time 14:40 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2010-08-13 Cont ID  
Sent By lfranco Date 2010-08-13 Time 18:58 Rev Time 0.00
Received By lfranco Date 2010-08-13 Time 18:58 Sent To B
Notes
2010-08-13 19:06:55PLANNING AND ZONING: **** FAILED ****
  
  
 1. RESPOND TO COMMENTS IN WRITING.
  
 2. THE PROPOSED PLANS SHOW AN OVERHEAD DOOR FACING THE
 SOUTH SIDE OF THE PROPERTY. IS THE INTENTION TO DRIVE
 THE GOLF CART OUT THROUGH THIS AREA, OVER THE SOD? WILL
 THERE BE ADDITIONAL WORK PERFORMED TO ACCOMMODATE CART
 DRIVING OVER SOD? PLEASE KEEP IN MIND THAT THERE IS AN
 EXISTING 15-FOOT UTILITY EASEMENT FROM THE SOUTH
 PROPERTY LINE.
  
 3. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
 THE SURVEY SUBMITTED WAS A PARTIAL ONE AND DOES NOT
 OBTAIN INFORMATION REQUIRED.
  
 4. HAS THE APPLICANT OBTAINED APPROVAL BY THE HOME
 OWNER'S ASSOCIATION ("HOA"), PROVIDE A COPY OF APPROVED
 PLANS AND LETTER.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]
  