Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-08-10 Cont ID  
Sent By jwitmer Date 2010-08-10 Time 11:12 Rev Time 0.55
Received By jwitmer Date 2010-08-10 Time 11:12 Sent To  
Notes
2010-08-10 11:14:18ELECTRICAL APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 2ND FLOOR A/C CLOSET NEC 110.26 WORKING CLEARENCES

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-08-12 Cont ID  
Sent By ssherman Date 2010-08-12 Time 09:45 Rev Time 0.00
Received By ssherman Date 2010-07-26 Time 11:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2010-08-10 Cont ID  
Sent By jwitmer Date 2010-08-10 Time 11:15 Rev Time 0.44
Received By jwitmer Date 2010-08-10 Time 11:14 Sent To  
Notes
2010-08-10 11:14:58MECHANICAL APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
  
 M1602.4 BALANCED RETURN AIR. RESTRICTED RETURN AIR
 OCCURS IN BUILDINGS WHEN RETURNS ARE LOCATED IN CENTRAL
 ZONES AND CLOSED INTERIOR DOORS IMPEDE AIR FLOW TO THE
 RETURN GRILL OR WHEN CEILING SPACES ARE USED AS RETURN
 PLENUMS AND FIRE WALLS RESTRICT AIR MOVEMENT FROM ONE
 PORTION OF THE RETURN PLENUM TO ANOTHER. PROVISIONS
 SHALL BE MADE IN RESIDENTIAL BUILDINGS TO AVOID
 UNBALANCED AIR FLOWS AND PRESSURE DIFFERENTIALS CAUSED
 BY RESTRICTED RETURN AIR. PRESSURE DIFFERENTIALS ACROSS
 CLOSED DOORS WHERE RETURNS ARE CENTRALLY LOCATED SHALL
 BE LIMITED TO 0.01 INCH WC (2.5 PA) OR LESS. PRESSURE
 DIFFERENTIALS ACROSS FIRE WALLS IN CEILING SPACE
 PLENUMS SHALL BE LIMITED TO 0.01 INCH WC (2.5 PA) BY
 PROVIDING AIR DUCT PATHWAYS OR AIR TRANSFER PATHWAYS
 FROM THE HIGH PRESSURE ZONE TO THE LOW ZONE.
  
 EXCEPTIONS:
  
 1. TRANSFER DUCTS MAY ACHIEVE THIS BY INCREASING THE
 RETURN TRANSFER ONE AND ONE HALF TIMES THE CROSS
 SECTIONAL AREA (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING AND THE DOOR
 HAVING AT LEAST AN UNRESTRICTED 1 INCH (25 MM) UNDERCUT
 TO ACHIEVE PROPER RETURN AIR BALANCE.
  
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-08-10 Cont ID  
Sent By jwitmer Date 2010-08-10 Time 11:15 Rev Time 0.50
Received By jwitmer Date 2010-08-10 Time 11:15 Sent To  
Notes
2010-08-10 11:17:56PLUMBING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
  
 2007 FBC-P 706.3 DOUBLE SANITARY TEE PATTERNS, CAUTION!

Review Stop Z ZONING
Rev No 1 Status P Date 2010-08-11 Cont ID  
Sent By jroach Date 2010-08-11 Time 09:27 Rev Time 0.00
Received By jroach Date 2010-08-11 Time 09:27 Sent To PC
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved