| 2010-07-26 13:46:48 | BUILDING PLAN REVIEW |
| | PERMIT: 10060179/ |
| | REVISION: 10070511 |
| | ADD: 512 SPENCER DR |
| | CONT: M. J. SIMPSON CORP. |
| | TEL: (954)275-5205 |
| | |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | BUILDING PROVISOS: |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | |
| | 1) SHEET AD-1.01 NOTE NUMBERS 4 & 5 & SHEET A-1.01, |
| | DOOR # 104-6 & 104-7 AND A-6.01 INDICATE THE REMOVAL |
| | AND REPLACEMENT OF DOORS. THE DOOR SCHEDULE INDICATE NO |
| | FIRE RATING. THIS WALL APPEARS TO BE A 4 HR FIRE WALL |
| | REQUIRING THESE DOORS TO HAVE 3 HOUR OPENING |
| | PROTECTIVES. 2007 FBC-B TABLE 715.4. |
| | |
| | 2) SHEET AD-1.01 NOTES 3 & 16 INDICATE THE REMOVAL OF |
| | STOREFRONT WINDOWS AND DOORS, SHEET A-1.01 INDICATE NEW |
| | STOREFRONT DOORS, THE S-1 SHEET PROVIDES THE ASSOCIATED |
| | POSITIVE & NEGATIVE PRESSURES, THE CONTRACTOR WILL NEED |
| | TO SUPPLY PRODUCT APPROVALS FOR THESE NEW COMPONENTS |
| | AND CLADDING. |
| | |
| | 2A) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, |
| | PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING |
| | REPORTS ARE AS FOLLOWS: |
| | 3A ) STOREFRONT EXTERIOR GLAZED DOORS. |
| | 3B) 7/26/2010 COMPLIED STOREFRONT WINDOW SYSTEM- ARCH |
| | NOA 09-1110.03 |
| | 3C) 3 HOUR FIRER RATED DOORS |
| | |
| | 2B) SEMI- COMPLIED STOREFRONT WINDOWS ARCH NOA |
| | 09-1110.03. 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY THE DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | 3) SHEET A-1.01 NEW ACCESSIBLE RAMP INDICATES THE |
| | BOTTOM LANDING TO BE A DISTANCE OF 4'-8" LONG, PLEASE |
| | REFER TO 11-4.8.4(2) THE BOTTOM OF EACH RAMP SHALL HAVE |
| | NOT LESS THAN 72" OF STRAIGHT & LEVEL CLEARANCE. |
| | |
| | 4) SHEET A-1.01 NOTE 28 INDICATES THE INSTALLATION OF |
| | NEW LANDING AND STAIRS. A-1.02 DETAILS 4 & 5 INDICATE A |
| | SECTION THROUGH THE STAIR BUT NO REFERENCE TO THE |
| | REQUIRED HANDRAILS FBC-B 1009.10 , 1012 & 11-4.1.3.8(D) |
| | . |
| | JIM WITMER C. B. O. |
| | COMMERCIAL COMBINATION PLAN REVIEW |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE |
| | CUSTOMER SERVICE SURVEY AT: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |