Plan Review Details - Permit 10070374
Plan Review Stops For Permit 10070374
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-07-28 Cont ID  
Sent By rmcdouga Date 2010-07-28 Time 10:29 Rev Time 0.00
Received By rmcdouga Date 2010-07-28 Time 10:29 Sent To  
Notes
2010-07-28 10:30:55REMOVED SOLAR ATTIC FAN FROM SCOPE OF WORK AT
 CONTRACTOR'S REQUEST. THE DESIGN PRESSURES FOR THE FAN
 WERE TOO LOW FOR EXPOSURE CATEGORY C.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-07-26 Cont ID  
Sent By rmcdouga Date 2010-07-26 Time 15:54 Rev Time 0.00
Received By rmcdouga Date 2010-07-26 Time 15:54 Sent To  
Notes
2010-07-26 15:55:29DENIED BY BUILDING
  
 1) THE DESIGN PRESSURES FOR THE SOLAR POWERED ATTIC
 ROOF FAN OF +21.8 PSF AND - 55.0 PSF ARE TOO LOW FOR
 EXPOSURE C WITH A 140 MPH WIND SPEED. COMPLY WITH FBC
 R301.2.1.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-07-26 Cont ID  
Sent By rmcdouga Date 2010-07-26 Time 15:55 Rev Time 0.00
Received By rmcdouga Date 2010-07-15 Time 09:36 Sent To  
Notes
2010-07-15 09:36:14IN ZONING BOX

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-07-26 Cont ID  
Sent By rmcdouga Date 2010-07-26 Time 15:55 Rev Time 0.00
Received By rmcdouga Date 2010-07-26 Time 15:55 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2010-07-20 Cont ID  
Sent By lfranco Date 2010-07-20 Time 09:27 Rev Time 0.00
Received By lfranco Date 2010-07-15 Time 12:47 Sent To P
Notes
***NONE***