| Plan Review Stops For Permit 10070257 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-08-09 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-08-09 |
Time |
09:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-07-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-07-14 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-07-14 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2010-07-14 16:58:34 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) THE TITLE BLOCK OF THE PLANS APPEARS TO BEAR THE | | | NAME OF A DESIGN PROFESSIONAL AND A DESIGN FIRM. FS 471 | | | AND FS 481 REQUIRE THE DESIGN PROFESSIONAL TO PROVIDE | | | THEIR LICENSE NUMBER AND TO SIGN, SEAL AND DATE THE | | | DRAWINGS. THE LICENSE NUMBER OF THE FIRM IS ALSO | | | REQUIRED ON THE DRAWINGS. ALTERNATELY, FS 471.003 | | | ALLOWS A FLORIDA LICENSED PLUMBING, ELECTRICAL OR | | | RESIDENTIAL CONTRACTOR TO DESIGN THE SYSTEMS THAT THEY | | | ARE LICENSED TO INSTALL UNDER CHAPTER 489. THE NAME, | | | LICENSE NUMBER AND SIGNATURE OF THE CONTRACT IS | | | REQUIRED ON THE DRAWINGS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2010-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-08-09 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-08-09 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2010-07-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-07-15 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-07-15 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2010-07-15 12:01:49 | 2007 FBC W/2009 REVISIONS | | | 2008 NEC | | | | | | DENIED BY ELECTRICAL | | | | | | 1) THE NAME, LICENSE NUMBER AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE ELECTRICAL DESIGN IS REQUIRED ON | | | THE PLANS. SEE BUILDING REVIEW COMMENTS. | | | | | | 2) SHOW COMPLIANCE WITH 2008 NEC 210.52 FOR RECEPTACLE | | | SPACING, 210.12 FOR ARC-FAULT AND FOR TAMPER-PROOF | | | RECEPTACLES IN THE NEW WALLS. | | | | | | 3) SMOKE ALARMS SHALL BE INSTALLED IN ACCORDANCE WITH | | | FBC R313.2.1. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2010-07-12 09:26:24 | PER J PAPA 7-8-10 NO FEE, INTERIOR WORK ONLY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-08-02 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-08-02 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-08-02 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2010-08-03 15:37:16 | 8/3/10 GAVE TO MCDOUGLE | | 2010-08-02 13:27:23 | IN ZONING BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-08-02 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-07-29 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-07-12 |
Time |
11:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2010-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-08-09 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-08-09 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2010-07-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-07-15 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-07-15 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2010-07-15 10:19:34 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY PLUMBING | | | | | | 1) THE NAME, LICENSE NUMBER AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN OF THE PLUMBING SYSTEM IS | | | REQUIRED ON THE PLANS. SEE BUILDING REVIEW COMMENTS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2010-08-03 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-08-03 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-08-03 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2010-08-03 15:36:44 | SEE PLANS FOR ZONING APPROVAL |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2010-07-29 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2010-07-29 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-07-29 |
Time |
15:34 |
Sent To |
B |
|
| Notes |
| 2010-08-03 15:35:10 | GAVE TO MCDOUGLE | | 2010-07-29 15:40:05 | AMY STELLY | | | PLANNING AND ZONING | | | 822-1442 | | | | | | PLANS ARE REQUIRED TO BE SIGNED AND SEALED. |
|
|