Plan Review Details - Permit 10070196
| Plan Review Stops For Permit 10070196 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-08-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-08-16 |
Time |
10:39 |
Rev Time |
0.10 |
| Received By |
jwitmer |
Date |
2010-08-16 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2010-08-16 10:40:09 | RESTAMP PLANS SUTTLE REVISIONS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2010-07-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-07-12 |
Time |
13:20 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2010-07-12 |
Time |
13:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-07-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-07-21 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-07-21 |
Time |
10:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2010-08-12 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2010-08-12 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2010-08-12 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2010-08-12 13:16:16 | *****APPROVED***** | | | | | | MIKE CARSILLO, BATTALION CHIEF | | | & WESLEY JOLIN | | | WPB FIRE PLAN REVIEW | | | 561-805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2010-08-03 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2010-08-03 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2010-08-03 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2010-08-03 12:26:50 | *****REVIEW COMMENTS - FIRE***** | | | | | | 1) PROVIDE SUITE NUMBER IN TITLE BLOCK INFORMATION. | | | | | | 2) PROVIDE MINIMUM 6" TALL ADDRESS SUITE NUMBER ON | | | BUILDING. | | | | | | 3) ALL DEMOLITION WORK SHALL COMPLY WITH NFPA 241. | | | | | | 4) ALL NEW WORK SHALL COMPLY WITH THE FLORIDA FIRE | | | PREVENTION CODE, 2007 EDITION. | | | | | | 5) SHEET A-1: "EXISTING/DEMO PLAN PLAN" DOES NOT APPEAR | | | TO BE SCALED AT 1/4"=1'-0". | | | | | | 6) SHEET A-2: PROVIDE PORTABLE FIRE EXTINGUISHERS PER | | | NFPA 10. | | | | | | 7) SHEET A-2: AUTOMOTIVE SERVICE AND REPAIR CLASSIFIES | | | AS AN INDUSTRIAL OCCUPANCY, NOT A BUSINESS OCCUPANCY. | | | | | | 8) SHEET A-2: PROVIDE EXIT SIGNAGE AND EMERGENCY | | | LIGHTING FOR SMALL CORRIDOR ADJACENT TO RESTROOM. | | | | | | 9) SHEET A-2: EXISTING RESTROOM DOOR SWING OBSTRUCTS | | | EGRESS FROM NEWLY FORMED CORRIDOR (NFPA 101, 2007 ED, | | | SECTION 7.2.1.4.4). | | | | | | 10) SHEET A-2: DOOR LOCKS SHALL BE OPERABLE FROM THE | | | EGRESS SIDE AND SHALL NOT REQUIRE THE USE OF A KEY, | | | TOOL, OR SPECIAL KNOWLEDGE TO OPEN. | | | | | | 11) SHEET A-2: ADDITIONAL FIRE SPRINKLERS WILL BE | | | REQUIRED BELOW THE NEW GARAGE DOOR. SEPARATE PLANS AND | | | PERMIT REQUIRED FOR FIRE SPRINKLER WORK. | | | | | | MIKE CARSILLO, BATTALION CHIEF | | | & WESLEY JOLIN | | | WPB FIRE PLAN REVIEW | | | 561-805-6730 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-08-12 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2010-08-12 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2010-08-11 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2010-08-11 08:23:15 | SENT TO FIRE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-08-03 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2010-08-03 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2010-07-08 |
Time |
12:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2010-07-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-07-19 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-07-19 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2010-07-19 13:02:26 | DO NOT NEED MECHANICAL PERMIT FOR DEMO . | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2010-07-22 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2010-07-22 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2010-07-22 |
Time |
12:46 |
Sent To |
P |
|
| Notes |
| 2010-07-22 12:49:11 | PLANNING AND ZONING: *** PASSED, *ZONING REVIEW NOT | | | REQUIRED: INTERIOR WORK ONLY AND THE VALUE OF PROPOSED | | | WORK DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE. **** | | | | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] |
|
|
|