Plan Review Details - Permit 10070075
Plan Review Stops For Permit 10070075
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-07-08 Cont ID  
Sent By jgomez Date 2010-07-08 Time 08:11 Rev Time 0.00
Received By jgomez Date 2010-07-08 Time 07:43 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-07-06 Cont ID  
Sent By jgomez Date 2010-07-06 Time 12:00 Rev Time 0.00
Received By jgomez Date 2010-07-06 Time 11:55 Sent To  
Notes
2010-07-06 12:10:55RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST.
 2007 FBC WITH 2009 REVISIONS.
  
 1- SPECIFY WHICH APPROVED ASSEMBLY OF NOA 08-0227.07
 SUBMITTED IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE
 WITH THE DESIGN PRESSURES OF SEC. R301 OF 2007 FLORIDA
 RESIDENTIAL CODE.
  
 2- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR
 NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS
 REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA
 SUBMITTED. THIS CALCULATIONS ARE REQUIRED TO MEET THE
 DESIGN PRESSURES OF SEC. R301. DESIGN PROFESSIONAL
 DOING THE RAS 117 CALCULATIONS TO TAKE INTO
 CONSIDERATION THAT ACCORDING TO THE 2009 REVISIONS THIS
 BUILDING IS IN EXPOSURE "C".
  
 ***NOTE: APPROVED ASEMBLIES THAT ARE LIMITED BY GENERAL
 LIMITATION #9 CAN'T BE USED IN THIS BUILDING BECAUSE
 THIS LIMITATION DOESN'T ALLOW NAIL ENHANCING. SEE LAST
 PAGE OF NOA SUBMITTED.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-07-06 Cont ID  
Sent By jgomez Date 2010-07-06 Time 11:55 Rev Time 0.00
Received By jgomez Date 2010-07-06 Time 11:55 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved