Plan Review Details - Permit 10060853
| Plan Review Stops For Permit 10060853 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-08-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-08-16 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-08-16 |
Time |
18:03 |
Sent To |
|
|
| Notes |
| 2010-08-16 18:09:53 | ****PROVISO**** | | | ****REVISION REQUIRED PRIOR TO FIRST INSPECTION**** | | | ****ISSUED AT CONTRACTOR'S RISK**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. PLEASE SUBMIT TWO SETS OF THE CORRECTED INSTALLATION | | | SCHEDULE, SEE FOLLOWING COMMENTS. | | | | | | 2. NEW DESIGN PRESSURES WERE SUBMITTED FOR EXP C BUT | | | THE INSTALLATION SCHEDULE WAS NOT REVISED TO IMPLEMENT | | | CORRECT PRESSURES. ANCHOR SPACING DOES NOT COMPLY, SEE | | | NOA. | | | | | | 3. INSTALLATION SCHEDULE STATES SUBSTRATE IS "C/B", | | | WHAT DOES THIS MEAN? CONCRETE BLOCK, TOP AND BOTTOM? | | | CONCRETE TOP, BLOCK BOTTOM? ANCHOR SPACING DOES NOT | | | COMPLY FOR BLOCK SUBSTRATE, PLEASE SEE NOA. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-07-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-07-07 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-07-07 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2010-07-07 15:23:36 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF | | | | | | 2. REVISE EXPOSURE CATEGORY TO EXPOSURE C. FBC1609, FBC | | | R301.2.1.4. NOTE THAT THE CODE CHANGED EFFECTIVE MARCH | | | 1, 2009. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-08-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-08-16 |
Time |
18:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-08-16 |
Time |
18:02 |
Sent To |
|
|
| Notes |
| 2010-07-29 16:56:40 | INCOMING SENET TO S HILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-07-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-07-07 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-06-30 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2010-06-30 08:27:44 | IN MISC.1 BOX |
|
|
|