Plan Review Details - Permit 10060823
Plan Review Stops For Permit 10060823
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2010-11-09 Cont ID  
Sent By shill Date 2010-11-09 Time 16:46 Rev Time 0.00
Received By shill Date 2010-11-09 Time 16:46 Sent To Z
Notes
2010-11-09 16:47:26PROVISO - INCORPORATE CHANGE INTO PLAN AND PROVIDE AT
 INSPECTION
  
 DETECTABLE WARNINGS TO COMPLY WITH FBC 11-4.29.2.
  
 RAMPS TO COMPLY WITH FBC 11-4.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2010-10-14 Cont ID  
Sent By shill Date 2010-10-14 Time 09:41 Rev Time 0.00
Received By shill Date 2010-10-14 Time 09:40 Sent To  
Notes
2010-10-14 12:40:32****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 THIRD REVIEW, SAME PLANS SUBMITTED AS #2 EXCEPT PLANS
 ARE FULL SIZE AND SIGNED & SEALED
  
 COMMENTS REMAIN THE SAME FROM PREVIOUS LIST FOR
 CONSISTENCY:
  
 1. FROM PREVIOUS REVIEW, PLEASE REVISE THE PLAN TO
 INCLUDE INFORMATION REGARDING THE ACCESSIBLE ROUTE AND
 THE ACCESSIBLE ENTRANCE(S). BASED ON INFORMATION
 PROVIDED REGARDING THE SITE, THE ACCESSIBLE SPACES
 SHOWN ARE NOT LOCATED ON THE SHORTEST ACCESSIBLE ROUTE,
 SEE FBC11-4.6.2.
  
 2ND REVIEW, BASED ON THE NEW INFORMATION PROVIDED, IT
 APPEARS THAT THE ACCESSIBLE PARKING IS LOCATED FARTHER
 FROM THE ACCESSIBLE ENTRANCE THAN OTHER SPACES. IT
 APPEARS THAT, RATHER THAN CREATE AN ACCESSIBLE ROUTE
 FROM FARTHER PARKING SPACES, THE ROUTE SHOULD BE
 CREATED FROM THE PARKING SPACES WHICH ARE CLOSEST TO
 THE ACCESSIBLE ENTRANCE.
  
 3RD REVIEW, SEE COMMENT FROM 2ND REVIEW. ALSO PLEASE
 NOTE THAT ONE OF THE PROPOSED ROUTE DIRECTS THE
 ACCESSIBLE ROUTE THROUGH TRAFFIC COMING IN OFF OF THE
 STREET. AS THIS IS A PARKING LOT, IT APPEARS THAT THE
 ACCESSIBLE ROUTE WILL CROSS TRAFFIC REGARDLESS OF
 LOCATION (AS IS TYPICAL OF MOST LARGE PARKING LOT
 CONFIGURATIONS). PLEASE SEE FBC11-4.6.2, ACCESSIBLE
 PARKING SPACES SHALL BE LOCATED ON THE SHORTEST SAFELY
 ACCESSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING TO AN
 ACCESSIBLE ENTRANCE.
  
 2. PLEASE PROVIDE DETAILS FOR THE RAMPS PROPOSED. NOTE
 THAT RAMPS ARE TO COMPLY WITH FBC11-4.7 (CURB RAMPS) OR
 FBC11-4.8 (RAMPS).
  
 2ND REVIEW, THE PLAN PROVIDED APPEARS TO BE AN 8 1/2" X
 11" REDUCED SHEET BASED ON A 24"X36" PLAN. IT IS VERY
 DIFFICULT TO READ. SOME NUMBERS ARE ENTIRELY ILLEGIBLE
 DUE TO THE VERY SMALL SIZE. PLEASE SUBMIT FULL SIZE
 PLANS. SEE FBC106, PLANS ARE TO BE LEGIBLE.
  
 A SP2, RAMP IS LABELED AS A CURB RAMP BUT NOT DRAWN AS
 SUCH, SEE FBC 11 FIGURE 12.
  
 SP2, SEE FBC 11 4.29.2 AND FIGURE 11 40. IT IS NOT
 CLEAR WHY THE DETECTABLE WARNING IN DETAIL A IS ON AN
 ANGLE, DETAIL B IS A SEMICIRCLE. A COMPLETE REVIEW OF
 THE DETAILS HAS NOT BEEN DONE AT THIS TIME PENDING A
 FULL SIZE DETAIL WITH LEGIBLE TEXT.
  
 3. SOME DETECTABLE WARNINGS ARE IN A SEMICIRCLE
 CONFIGURATION OR ON AN ANGLE, PLEASE CLARIFY. PLEASE
 SEE EXAMPLES NOTED IN 2ND REVIEW ITEM 2. ALSO SEE
 FBC11-4.7, REGARDING CURB RAMP DETECTABLE WARNINGS.
  
 4-5. ADDRESSED.
  
 6. PROVIDE A COPY OF THE CONTRACT FOR THIS JOB.
  
 NOT ADDRESSED; THIRD REQUEST. THE CONTRACT SHOULD
 INCLUDE A COST BREAKDOWN, FBC11-4.1.6(2).
  
 7. DETAIL 2 SP1, HANDICAP PARKING SIGN TO INCLUDE THE
 FINE AND THE 84" DIMENSION SHOULD BE FROM GRADE TO
 BOTTOM OF SIGN (DIMENSION APPEARS TO BE RELATED TO
 FOOTING), FBC11-4.6.4.
  
 8. (NEW COMMENT, THIRD REVIEW) - PLEASE NOTE THAT MOST
 ITEMS CAN BE PROVISO OR REDLINE ITEMS AFTER RESOLUTION
 OF THE LOCATION ISSUE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2010-09-16 Cont ID  
Sent By shill Date 2010-09-16 Time 13:52 Rev Time 0.00
Received By shill Date 2010-09-16 Time 13:52 Sent To  
Notes
2010-09-16 14:46:31****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 COMMENTS REMAIN THE SAME FROM PREVIOUS LIST FOR
 CONSISTENCY:
  
 1. FROM PREVIOUS REVIEW, PLEASE REVISE THE PLAN TO
 INCLUDE INFORMATION REGARDING THE ACCESSIBLE ROUTE AND
 THE ACCESSIBLE ENTRANCE(S). BASED ON INFORMATION
 PROVIDED REGARDING THE SITE, THE ACCESSIBLE SPACES
 SHOWN ARE NOT LOCATED ON THE SHORTEST ACCESSIBLE ROUTE,
 SEE FBC11-4.6.2.
  
 2ND REVIEW, BASED ON THE NEW INFORMATION PROVIDED, IT
 APPEARS THAT THE ACCESSIBLE PARKING IS LOCATED FARTHER
 FROM THE ACCESSIBLE ENTRANCE THAN OTHER SPACES. IT
 APPEARS THAT, RATHER THAN CREATE AN ACCESSIBLE ROUTE
 FROM FARTHER PARKING SPACES, THE ROUTE SHOULD BE
 CREATED FROM THE PARKING SPACES WHICH ARE CLOSEST TO
 THE ACCESSIBLE ENTRANCE.
  
 2. PLEASE PROVIDE DETAILS FOR THE RAMPS PROPOSED. NOTE
 THAT RAMPS ARE TO COMPLY WITH FBC11-4.7 (CURB RAMPS) OR
 FBC11-4.8 (RAMPS).
  
 2ND REVIEW, THE PLAN PROVIDED APPEARS TO BE AN 8 1/2" X
 11" REDUCED SHEET BASED ON A 24"X36" PLAN. IT IS VERY
 DIFFICULT TO READ. SOME NUMBERS ARE ENTIRELY ILLEGIBLE
 DUE TO THE VERY SMALL SIZE. PLEASE SUBMIT FULL SIZE
 PLANS. SEE FBC106, PLANS ARE TO BE LEGIBLE.
  
 A SP2, RAMP IS LABELED AS A CURB RAMP BUT NOT DRAWN AS
 SUCH, SEE FBC 11 FIGURE 12.
  
 SP2, SEE FBC 11 4.29.2 AND FIGURE 11 40. IT IS NOT
 CLEAR WHY THE DETECTABLE WARNING IN DETAIL A IS ON AN
 ANGLE, DETAIL B IS A SEMICIRCLE. A COMPLETE REVIEW OF
 THE DETAILS HAS NOT BEEN DONE AT THIS TIME PENDING A
 FULL SIZE DETAIL WITH LEGIBLE TEXT.
  
 3. PROVIDE DETAILS FOR ALL PROPOSED CONSTRUCTION. RAMPS
 AND DETECTABLE WARNINGS ARE SHOWN ON THE PLAN, PLEASE
 PROVIDE DETAILS.
  
 2ND REVIEW, PLEASE PROVIDE A FULL SIZE PLAN FOR REVIEW.
  
 4. REVISE PLAN TO PROVIDE ENOUGH INFORMATION TO SHOW
 SITE CONDITIONS. FOR INSTANCE, I CANNOT DETERMINE WHAT
 AREAS ARE LANDSCAPE, WALLS, OR SIDEWALKS. THIS
 INFORMATION IS REQUIRED TO DETERMINE WHETHER OR NOT
 EDGE PROTECTION WOULD BE REQUIRED, FBC11-4.8.7. THIS IS
 NOT REQUIRED FOR THE ENTIRE SITE, BUT SHOULD BE
 PROVIDED FOR AREAS OF CONSTRUCTION.
  
 PLEASE SEE OTHER COMMENTS REGARDING FULL SIZE PLANS. MY
 UNDERSTANDING IS THAT THERE IS A WALL LOCATED ADJACENT
 TO THE SIDEWALK, BUT NOT SHOWN ON THE PLAN. IT IS NOT
 CLEAR WHAT ELEMENTS ARE BETWEEN THE EXISTING ACCESSIBLE
 PARKING SPACE (WHICH YOU PROPOSE TO ELIMINATE) AND THE
 ACCESSIBLE ENTRANCE.
  
 5. THE PLAN IS TO INCLUDE THE NAME AND SIGNATURE OF THE
 INDIVIDUAL TAKING RESPONSIBILITY FOR THE DESIGN (MUST
 BE A LICENSED PROFESSIONAL).
  
 2ND REVIEW, DOCUMENTS PREPARED BY AN ARCHITECT AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS FS481.
  
 6. PROVIDE A COPY OF THE CONTRACT FOR THIS JOB.
  
 7. (NEW COMMENT) DETAIL 2 SP1, HANDICAP PARKING SIGN TO
 INCLUDE THE FINE AND THE 84" DIMENSION SHOULD BE FROM
 GRADE TO BOTTOM OF SIGN (DIMENSION APPEARS TO BE
 RELATED TO FOOTING), FBC11-4.6.4.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-07-20 Cont ID  
Sent By shill Date 2010-07-20 Time 16:15 Rev Time 0.00
Received By shill Date 2010-07-20 Time 16:15 Sent To  
Notes
2010-07-20 16:34:34****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. PLEASE REVISE THE PLAN TO INCLUDE INFORMATION
 REGARDING THE ACCESSIBLE ROUTE AND THE ACCESSIBLE
 ENTRANCE(S). BASED ON INFORMATION PROVIDED REGARDING
 THE SITE, THE ACCESSIBLE SPACES SHOWN ARE NOT LOCATED
 ON THE SHORTEST ACCESSIBLE ROUTE, SEE FBC11-4.6.2.
  
 2. PLEASE PROVIDE DETAILS FOR THE RAMPS PROPOSED. NOTE
 THAT RAMPS ARE TO COMPLY WITH FBC11-4.7 (CURB RAMPS) OR
 FBC11-4.8 (RAMPS).
  
 3. PROVIDE DETAILS FOR ALL PROPOSED CONSTRUCTION. RAMPS
 AND DETECTABLE WARNINGS ARE SHOWN ON THE PLAN, PLEASE
 PROVIDE DETAILS.
  
 4. REVISE PLAN TO PROVIDE ENOUGH INFORMATION TO SHOW
 SITE CONDITIONS. FOR INSTANCE, I CANNOT DETERMINE WHAT
 AREAS ARE LANDSCAPE, WALLS, OR SIDEWALKS. THIS
 INFORMATION IS REQUIRED TO DETERMINE WHETHER OR NOT
 EDGE PROTECTION WOULD BE REQUIRED, FBC11-4.8.7. THIS IS
 NOT REQUIRED FOR THE ENTIRE SITE, BUT SHOULD BE
 PROVIDED FOR AREAS OF CONSTRUCTION.
  
 5. THE PLAN IS TO INCLUDE THE NAME AND SIGNATURE OF THE
 INDIVIDUAL TAKING RESPONSIBILITY FOR THE DESIGN (MUST
 BE A LICENSED PROFESSIONAL).
  
 6. PROVIDE A COPY OF THE CONTRACT FOR THIS JOB.
  
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2010-11-29 Cont ID  
Sent By mgonzale Date 2010-11-29 Time 10:07 Rev Time 0.50
Received By mgonzale Date 2010-11-29 Time 10:07 Sent To  
Notes
2010-11-29 10:07:59PASSED:
  
 STRIPPING CROSSWALK.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2010-06-29 Cont ID  
Sent By dlauderm Date 2010-06-29 Time 10:54 Rev Time 1.50
Received By dlauderm Date 2010-06-29 Time 09:54 Sent To  
Notes
2010-06-29 10:55:52IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 REVIEWER: DEAN S. LAUDERMILK, PROJECT COORDINATOR
 EMAIL: [email protected]
 OFFICE: 561-494-1083 (ENGINEERING)
 OFFICE: 561-805-6716 (CONSTRUCTION SERVICES)
 REVIEW STATUS: PASSED WITH PROVISOS
 1) UNLESS THE SIDEWALK IS WIDE ENOUGH THE CR3 DETAIL
 WILL NEED TO BE USED.
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2010-12-08 Cont ID  
Sent By jgomez Date 2010-12-08 Time 15:16 Rev Time 0.00
Received By jgomez Date 2010-12-08 Time 15:16 Sent To  
Notes
2010-11-29 10:44:4511/29 TO ZONING
  
2010-11-03 08:22:01TO SH DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2010-10-28 Cont ID  
Sent By lmartine Date 2010-10-28 Time 13:09 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2010-10-28 13:09:33GAVE TO SAMANTHA

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2010-09-29 Cont ID  
Sent By rmcdouga Date 2010-09-29 Time 10:06 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2010-09-29 10:06:52TO S HILL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-09-07 Cont ID  
Sent By rmcdouga Date 2010-09-07 Time 11:05 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2010-09-07 11:06:10TO S.HILL'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-07-20 Cont ID  
Sent By shill Date 2010-07-20 Time 16:34 Rev Time 0.00
Received By shill Date 2010-06-29 Time 09:02 Sent To  
Notes
2010-06-29 09:02:40IN ENGINEERING BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2010-12-01 Cont ID  
Sent By ajones Date 2010-12-01 Time 08:47 Rev Time 0.00
Received By ajones Date 2010-11-29 Time 16:45 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2010-07-07 Cont ID  
Sent By eschneid Date 2010-07-07 Time 08:43 Rev Time 0.25
Received By eschneid Date 2010-07-07 Time 08:43 Sent To B
Notes
***NONE***