| Plan Review Stops For Permit 10060769 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-06-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-06-30 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-06-30 |
Time |
11:39 |
Sent To |
I |
|
| Notes |
| 2010-06-30 11:42:18 | SEE THE FOLLOWING 2008 CODE CHANGES: | | | | | | 210.4 (B) DISCONNECTING MEANS. EACH MULTIWIRE BRANCH | | | CIRCUIT SHALL BE PROVIDED WITH A MEANS THAT WILL | | | SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS AT | | | THE POINT WHERE THE BRANCH CIRCUIT ORIGINATES. | | | | | | 210.4 (D) GROUPING. THE UNGROUNDED AND GROUNDED | | | CONDUCTORS OF EACH MULTIWIRE BRANCH CIRCUIT SHALL BE | | | GROUPED BY WIRE TIES OR SIMILAR MEANS IN AT LEAST ONE | | | LOCATION WITHIN THE PANELBOARD OR OTHER POINT OF | | | ORIGINATION. | | | | | | 210.12 (B) DWELLING UNITS. ALL 120-VOLT, SINGLE PHASE, | | | 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS | | | INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, | | | LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, | | | SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR | | | SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED | | | ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE, | | | INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. | | | | | | 406.11 TAMPER-RESISTANT RECEPTACLES IN DWELLING UNITS. | | | IN ALL AREAS SPECIFIED IN 210.52, ALL 125-VOLT, 15- AND | | | 20-AMPERE RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT | | | RECEPTACLES. | | | | | | SMOKE ALARMS MUST BE INSTALLED TO COMPLY WITH R313.2 | | | RESIDENTIAL FLORIDA BUILDING CODE. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-06-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-06-30 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-06-28 |
Time |
10:06 |
Sent To |
PC |
|
| Notes |
| 2010-06-28 10:06:27 | UNDER 5K ELECTRIC |
|
|
|