Plan Review Details - Permit 10060527
| Plan Review Stops For Permit 10060527 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2010-08-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-08-02 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-08-02 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2010-08-02 09:10:57 | PROVISO - SEPARATE PERMIT REQUIRED FOR SHUTTERS BEFORE | | | FIRST INSPECTION | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2010-07-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-07-28 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-07-28 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2010-07-28 16:41:16 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | | | | 1. SEE ENGINEERING FOR DESIGN PRESSURES. INSTALLATION | | | SCHEDULE, SHUTTER INSTALLATION IS DESIGNED TO -40PSF, | | | PRESSURES OF -76.9 REQUIRED. | | | | | | 2. PROVIDE A COPY OF THE CONTRACT FOR THIS JOB. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-06-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-06-23 |
Time |
18:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-06-23 |
Time |
18:31 |
Sent To |
|
|
| Notes |
| 2010-06-23 18:38:06 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | | | | 1. IMPACT PROTECTION REQUIRED,FBC1609.1.4. NONE SHOWN | | | AND NO EVIDENCE IN OUR RECORDS OF FBC COMPLIANT IMPACT | | | PROTECTION. | | | | | | 2. PROVIDE A PLAN SHOWING PROPOSED LOCATION. | | | | | | 3. IF THE DOOR PROPOSED WHEN RESUBMITTING IS NON | | | IMPACT, PLEASE SEE FBC1003.6, MEANS OF EGRESS | | | CONTINUITY. IF USE OF A SHUTTER OVER A NON IMPACT DOOR | | | IS PROPOSED, THE FOLLOWING INFORMATION IS REQUIRED: | | | | | | FLOOR PLAN WITH OVERALL DIMENSIONS | | | OCCUPANCY CLASSIFICATION FBC CH 3 | | | OCCUPANT LOAD FBC CH 10 | | | LOCATION OF EXITS/EXIT LIGHTS | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-07-15 |
|
|
Cont ID |
|
| Sent By |
vmolina |
Date |
2010-07-15 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
vmolina |
Date |
2010-07-15 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2010-07-15 09:59:59 | GAVE TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-06-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-06-23 |
Time |
18:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-06-17 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2010-06-22 09:04:17 | UNDER 5K BUILDING |
|
|
|