Plan Review Details - Permit 10060438
Plan Review Stops For Permit 10060438
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-08-17 Cont ID  
Sent By jwitmer Date 2010-08-17 Time 11:20 Rev Time 0.77
Received By jwitmer Date 2010-08-17 Time 11:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-07-08 Cont ID  
Sent By jwitmer Date 2010-07-08 Time 10:02 Rev Time 0.77
Received By jwitmer Date 2010-07-08 Time 10:02 Sent To  
Notes
2010-07-08 10:25:34BUILDING PLAN REVIEW
 PERMIT: 10060438
 ADD: 2900 N FLAGLER DR
 CONT: O/B CHRISTENSEN, JOHN PETER
 TEL: (561)655-2225
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PLANS ARE MISSING WIND DESIGN CRITERIA: 1609.6.2
 WIND DESIGN PROCEDURES
 1.1) THE BASIC WIND SPEED, V, SHALL BE DETERMINED IN
 ACCORDANCE WITH SECTION 1609.3. THE WIND SHALL BE
 ASSUMED TO COME FROM ANY HORIZONTAL DIRECTION.
  
 1.2) AN IMPORTANCE FACTOR, IW, SHALL BE DETERMINED IN
 ACCORDANCE WITH SECTION1609.5.
  
 1.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4.
  
 1.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.6.2.1(4)
  
 2) PLANS ARE MISSING INFORMATION, ADMINISTRATIVE CODE
 106.1.2 ADDITIONAL INFORMATION REQUIRED:
  
 2A) PLEASE PROVIDE SIZE OF CONCRETE FOOTERS, THE
 DIMENSION CENTER TO CENTER, STRENGHT OF CONCRETE, IF
 REBAR IS GOING TO BE PLACED WITHIN THE FOOTER. PLEASE
 NOTE HOW PLANS ARE DRAWN WITH THE DAVIT CENTERED WITHIN
 THE FOOTPRINT OF THE BOAT. SPECIFICATIONS RECOMMEND THE
 DAVITS SHOULD BE PLACED 2'-0" CENTER TO CENTER FURTHER
 APART THAN THE OVER ALL LENGHT OF THE BOAT.
  
 IN DETAILS THE CENTER TO CENTER FOR THE ANCHOR BOLTS IS
 21 3/4" BE AWARE A MINIMUM CONCRETE COVERAGE, CONCRETE
 CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH, A
 MINIMUM OF 3" COVERAGE FBC-B TABLE 1907.7.1.
  
  
 2B) PROVIDE THE WEIGHT OF THE BOAT FOR THE SIZING OF
 FOUNDATIONS AS RECOMENDED BY MANUFACTURER.
  
 2C) PLANS INDICATE A QUANITY OF (4) ANCHOR BOLTS BUT
 THE SIZE, LENGHT NOR TYPE OF MATERIAL FOR THE ANCHOR
 BOLTS THAT ARE TO BE INSTALLED.
  
 INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES
 DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER
 NOTICE.
  
 OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM
 - 5:00 PM.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-07-08 Cont ID  
Sent By jwitmer Date 2010-07-08 Time 09:51 Rev Time 0.00
Received By jwitmer Date 2010-06-16 Time 08:22 Sent To  
Notes
2010-06-16 08:22:17IN ZONING BOX

Review Stop Z ZONING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2010-08-16 Cont ID  
Sent By jroach Date 2010-08-16 Time 13:32 Rev Time 0.00
Received By jroach Date 2010-08-16 Time 13:32 Sent To B
Notes
2010-08-16 14:55:29ZONING PLAN REVIEW
  
 PERMIT NO.: 10060438
 ADDRESS: 2900 NORTH FLAGLER DRIVE
 CONTRACTOR/CONTACT: JOHN CHRISTENSEN
 TELEPHONE NO.: 561.655.1060
 SCOPE OF REVIEW: REPLACE ONE (1) SET OF DINGY DAVITS.
  
 REVIEW STATUS: FAILED
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 THE FOLLOWING COMMENTS ARE REPEAT COMMENTS. ADDITIONAL
 INFORMATION, IF ANY, HAS BEEN PROVIDED IN ALL CAPS:
  
 1) PLEASE CLARIFY SCOPE OF WORK???PERMIT APPLICATION
 INDICATES REPLACEMENT OF DINGY DAVITS; HOWEVER, THE
 SURVEY AND AERIAL PHOTOS DO NOT INDICATE ANY EXISTING
 DAVITS. NO ADDITIONAL INFORMATION WAS PROVIDED TO
 CLARIFY THIS COMMENT.
  
 2) PURSUANT TO SECTION 94-304(E)(1)(C)(5)(I) OF THE
 CITY???S ZONING AND LAND DEVELOPMENT REGULATIONS
 (ZLDRS), SINGLE FAMILY RESIDENCES SHALL BE LIMITED TO A
 MAXIMUM OF TWO (2) MOORING SLIPS. ACCORDING TO THE
 SURVEY AND AERIAL PHOTOS, THE SUBJECT PROPERTY ALREADY
 HAS TWO (2) MOORING SLIPS; NO ADDITIONAL SLIPS MAY BE
 ADDED. THE PLANNING DEPARTMENT HAS RECEIVED YOUR
 INFORMATION REGARDING THE DEFINITIONS OF DAVITS VS.
 MOORING. UPON PRESENTATION TO THE PLANNING & ZONING
 ADMINISTRATOR, AS WELL AS THE PLANNING DIRECTOR, IT WAS
 DETERMINED BY THIS DEPARTMENT THAT THE PROPOSED DAVITS
 ARE A ???MOORING RELATED FACILITY??? AND SUBJECT TO THE
 REQUIREMENTS OF SECTION 94-304(E)(1)(C) OF THE CITY???S
 ZONING AND LAND DEVELOPMENT REGULATIONS. IF YOU DIFFER
 WITH THIS INTERPRETATION, AN APPLICATION FOR AN
 ADMINISTRATIVE APPEAL MAY BE SUBMITTED AND WILL BE
 PRESENTED TO THE ZONING BOARD OF APPEALS (ZBA). PLEASE
 CONTACT ME REGARDING INFORMATION PERTAINING TO THIS
 APPLICATION.
  
 3) PURSUANT TO SECTION 94-304(E)(1)(C)(9) OF THE
 CITY???S ZLDRS, ALL MOORING-RELATED FACILITIES SHALL BE
 CONSTRUCTED WITHIN THE MIDDLE 1/3 OF THE PROPERTY. SEE
 ADDITIONAL INFORMATION CONTAINED IN COMMENT #2 ABOVE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 PLANNING AND ZONING DEPARTMENT
 401 CLEMATIS STREET - P.O. BOX 3366
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1435
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.CITYOFWPB.COM
  

Review Stop Z ZONING
Rev No 1 Status F Date 2010-06-23 Cont ID  
Sent By jroach Date 2010-06-23 Time 14:09 Rev Time 0.00
Received By jroach Date 2010-06-18 Time 13:41 Sent To B
Notes
2010-07-12 09:43:32ZONING PLAN REVIEW
  
 PERMIT NO.: 10060438
 ADDRESS: 2900 NORTH FLAGLER DRIVE
 CONTRACTOR/CONTACT: JOHN CHRISTENSEN
 TELEPHONE NO.: 561.655.1060
 SCOPE OF REVIEW: REPLACE ONE (1) SET OF DINGY DAVITS.
  
 REVIEW STATUS: FAILED
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1) PLEASE CLARIFY SCOPE OF WORK???PERMIT APPLICATION
 INDICATES REPLACEMENT OF DINGY DAVITS; HOWEVER, THE
 SURVEY AND AERIAL PHOTOS DO NOT INDICATE ANY EXISTING
 DAVITS.
  
 2) PURSUANT TO SECTION 94-304(E)(1)(C)(5)(I) OF THE
 CITY???S ZONING AND LAND DEVELOPMENT REGULATIONS
 (ZLDRS), SINGLE FAMILY RESIDENCES SHALL BE LIMITED TO A
 MAXIMUM OF TWO (2) MOORING SLIPS. ACCORDING TO THE
 SURVEY AND AERIAL PHOTOS, THE SUBJECT PROPERTY ALREADY
 HAS TWO (2) MOORING SLIPS; NO ADDITIONAL SLIPS MAY BE
 ADDED.
  
 3) PURSUANT TO SECTION 94-304(E)(1)(C)(9) OF THE
 CITY???S ZLDRS, ALL MOORING-RELATED FACILITIES SHALL BE
 CONSTRUCTED WITHIN THE MIDDLE 1/3 OF THE PROPERTY.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 PLANNING AND ZONING DEPARTMENT
 401 CLEMATIS STREET - P.O. BOX 3366
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1435
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.CITYOFWPB.COM
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved