Plan Review Details - Permit 10060353
Plan Review Stops For Permit 10060353
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-06-16 Cont ID  
Sent By jwitmer Date 2010-06-16 Time 11:53 Rev Time 0.55
Received By jwitmer Date 2010-06-16 Time 11:53 Sent To  
Notes
2010-06-16 11:54:41 
 BUILDING PROVISO:
 IF WINDOWS ARE REPLACED IN SLEEPING ROOMS.
 SECTION 1026: EMERGENCY ESCAPE AND RESCUE
  
 1026.2 MINIMUM SIZE. EMERGENCY ESCAPE AND RESCUE
 OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7
 SQUARE FEET (0.53 M2).
  
 EXCEPTION: THE MINIMUM NET CLEAR OPENING FOR EMERGENCY
 ESCAPE AND RESCUE GRADE-FLOOR OPENINGS SHALL BE 5
 SQUARE FEET (0.46 M2).
  
 1026.2.1 MINIMUM DIMENSIONS. THE MINIMUM NET CLEAR
 OPENING HEIGHT DIMENSION SHALL BE 24 INCHES (610 MM).
 THE MINIMUM NET CLEAR OPENING WIDTH DIMENSION SHALL BE
 20 INCHES (508 MM). THE NET CLEAR OPENING DIMENSIONS
 SHALL BE THE RESULT OF NORMAL OPERATION OF THE OPENING.
  
 1026.3 MAXIMUM HEIGHT FROM FLOOR. EMERGENCY ESCAPE AND
 RESCUE OPENINGS SHALL HAVE THE BOTTOM OF THE CLEAR
 OPENING NOT GREATER THAN 44 INCHES (1118 MM) MEASURED
 FROM THE FLOOR.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-06-16 Cont ID  
Sent By jwitmer Date 2010-06-16 Time 11:53 Rev Time 0.00
Received By jwitmer Date 2010-06-14 Time 12:29 Sent To  
Notes
2010-06-14 12:29:35IN MISC.1 BOX