| Plan Review Stops For Permit 10060348 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2010-06-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-06-29 |
Time |
13:31 |
Rev Time |
1.30 |
| Received By |
jwitmer |
Date |
2010-06-29 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2010-06-29 13:32:32 | BUILDING PROVISO: | | | BUILDING PROVISO: R703.6.3 WHERE CEMENT PLASTER | | | (STUCCO) IS TO BE APPLIED TO LATH OVER FRAME | | | CONSTRUCTION, MEASURES SHALL BE TAKEN TO PREVENT | | | BONDING BETWEEN THE CEMENT PLASTER AND THE | | | WATER-RESISTIVE BARRIER. A BOND BREAK SHALL BE PROVIDED | | | BETWEEN THE WATER-RESISTIVE BARRIER AND THE CEMENT | | | PLASTER (STUCCO) CONSISTING OF ONE OF THE FOLLOWING: | | | 1. TWO LAYERS OF AN APPROVED WATER-RESISTANT BARRIER | | | MATERIAL; OR | | | 2. ONE LAYER OF AN APPROVED WATER-RESISTANT BARRIER | | | OVER AN APPROVED PLASTIC HOUSE WRAP; OR | | | 3. OTHER APPROVED METHODS OR MATERIALS APPLIED IN | | | ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-06-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-06-24 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-06-24 |
Time |
15:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-07-23 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-07-23 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-07-23 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2010-07-23 12:38:26 | GAVE TO ROBBIE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-07-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-07-13 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-06-14 |
Time |
12:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2010-07-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-07-29 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-07-29 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2010-06-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-06-29 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2010-06-29 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2010-06-29 13:36:24 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2010-07-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-07-28 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-07-28 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2010-07-28 09:55:26 | OWNER BUILDER REQUESTED THAT MECHANICAL PLANS BE | | | REMOVED. NO MECHANICAL SUB WAS LISTED ON APPLICATION. | | | THE MECHANICAL CONTRACTOR WILL SUBMIT PLANS AND APPLY | | | FOR MECHANICAL PERMIT AT A LATER DATE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2010-07-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-07-27 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-07-27 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2010-07-27 10:19:47 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY MECHANICAL | | | | | | 1) THE PLANS DO NOT LIST THE LICENSE NUMBER OF THE | | | PERSON RESPONSIBLE FOR THE MECHANICAL SYSTEM DESIGN. | | | FBC 13-103.2 | | | | | | 2) THE RETURN AIR AS SHOWN ON THE PLANS IS TOO SMALL. | | | THE PLANS SPECIFY A LOUVER BIFOLD DOOR ON THE A/C | | | CLOSET WHICH IS LOCATED IN BEDROOM #2. THE RETURN AIR | | | FROM THE REST OF THE HOUSE WOULD HAVE TO ENTER THE | | | BEDROOM THROUGH A 9" TRANSFER DUCT WITH A 10" X 10" | | | GRILL. PLEASE CORRECT. | | | | | | 3) THE SIZE OF THE DUCT SUPPLYING BEDROOM #2 IS NOT | | | SPECIFIED ON THE PLANS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2010-07-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-07-12 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-07-12 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2010-07-12 17:01:05 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY MECHANICAL | | | | | | 1) THE EQUIPMENT SIZING CALCULATIONS WERE DONE USING | | | WORST-CASE DIRECTIONAL ORIENTATION. SECTION 13-607.AB.1 | | | OF THE REVISED ENERGY CODE DOES NOT PERMIT THIS. PLEASE | | | REVISE. | | | | | | 2) THE MECHANICAL PLANS ARE REQUIRED TO HAVE THE NAME, | | | LICENSE NUMBER AND SIGNATURE OF THE PERSON RESPONSIBLE | | | FOR THE DESIGN. FBC SECTION 106.1 AND FS 489. | | | | | | 3) THE OWNER/AGENT IS REQUIRED TO SIGN AND DATE THE | | | ENERGY CALCULATION FORMS. | | | | | | 4) THE ENERGY CALC. FORMS DO NOT SPECIFY THE OWNERS | | | NAME OR THE ADDRESS OF THE PROJECT. PLEASE CORRECT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2010-07-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-07-12 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-07-12 |
Time |
15:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2010-07-12 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2010-07-12 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2010-07-12 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|