| Plan Review Stops For Permit 10060173 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-08-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-08-09 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2010-08-09 |
Time |
11:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-06-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-06-10 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-08-24 |
Time |
17:50 |
Sent To |
|
|
| Notes |
| 2010-06-10 12:43:36 | BUILDING PLAN REVIEW | | | PERMIT: 10060173 | | | ADD: 201 S NARCISSUS # 120 | | | CONT: BEST INTERIOR CONSTRUCTION | | | TEL: (561)640-3010 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) SHEET A.3 INDICATES THE USE OF WOOD LAMINATE | | | FLOORING. PLEASE PROVIDE DOCUMENTATION INDICATING | | | COMPLIANCE WITH FBC-B 805.1 APPLICATION. COMBUSTIBLE | | | MATERIALS INSTALLED ON OR EMBEDDED IN FLOORS OF | | | BUILDINGS OF TYPE I OR II CONSTRUCTION SHALL COMPLY | | | WITH SECTIONS 805.1.1 THROUGH 805.1.3. | | | | | | 2) SHEET A.4 PROVIDES ELEVATIONS FOR VARIOUS CEILINGS | | | BUT NO ADDITIONAL INFORMATION IS PROVIDED FOR THE TYPE | | | OF CEILING MATERIALS, FRAMING, AND OR HANGING | | | MATERIALS. | | | | | | 3) PLANS DO NOT PROVIDE FOR WALL FINISHES, 803.1 | | | GENERAL. INTERIOR WALL AND CEILING FINISHES SHALL BE | | | CLASSIFIED IN ACCORDANCE WITH ASTM E 84. SUCH INTERIOR | | | FINISH MATERIALS SHALL BE GROUPED IN THE FOLLOWING | | | CLASSES IN ACCORDANCE WITH THEIR FLAME SPREAD AND | | | SMOKE-DEVELOPED INDEXES. | | | | | | 4) SHEET A.2 THE LIFE SAFETY PLAN DOES NOT INDICATE | | | WHERE DISPLAYS RACKS OR OTHER ASSOCIATED SALES ITEMS | | | ARE LOCATED WITHIN A MERCANTILE OCCUPANCY. | | | | | | JIM WITMER C. B. O. | | | COMMERCIAL COMBINATION PLAN REVIEW | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | | CUSTOMER SERVICE SURVEY AT: | | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2010-08-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-08-24 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-08-24 |
Time |
17:51 |
Sent To |
|
|
| Notes |
| 2010-08-24 17:54:21 | OK PER JOHN DICKINSON CONTRACT PLAN REVIEWER PX3182 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2010-06-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-06-15 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-06-14 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2010-06-15 12:20:34 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2007 FLORIDA BUILDING CODE, 2009 REVISIONS, 2008 | | | NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING | | | | | | 1} 13-415.AB.5 INTERIOR LIGHTING POWER, SCOPE. THE | | | INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING OR A | | | SEPARATELY METERED OR PERMITTED PORTION OF A BUILDING | | | SHALL BE DETERMINED BY THE SPACE-BY-SPACE METHOD | | | DESCRIBED IN SECTION 13-415.B.1. TRADE-OFFS OF INTERIOR | | | LIGHTING POWER ALLOWANCE AMONG PORTIONS OF THE BUILDING | | | FOR WHICH A DIFFERENT METHOD OF CALCULATION HAS BEEN | | | USED ARE NOT PERMITTED. THE INSTALLED INTERIOR LIGHTING | | | POWER IDENTIFIED IN ACCORDANCE WITH SECTION | | | 13-415.AB.5.1 SHALL NOT EXCEED THE INTERIOR LIGHTING | | | POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH | | | SECTION13-415.B.1*** SHOW COMPLIANCE ON THE PLAN. THIS | | | CAN BE DEMONSTRATED ON THE PLANS INDICATING THE | | | WATTAGES OF THE LUMINAIRES CHOSEN FOR THE PROJECT | | | CONFORM TO THE DENSITY REQUIREMENTS. INDICATE WATTAGES | | | ON THE FIXTURE SCHEDULE TO CORRELATE WITH THE ONES IN | | | THE CALCULATIONS. | | | | | | 2} 13-415.1.AB.1.2 SPACE CONTROL. | | | EACH SPACE ENCLOSED BY CEILING-HEIGHT PARTITIONS SHALL | | | HAVE AT LEAST ONE CONTROL DEVICE TO INDEPENDENTLY | | | CONTROL THE GENERAL LIGHTING WITHIN THE SPACE. EACH | | | MANUAL DEVICE SHALL BE READILY ACCESSIBLE AND LOCATED | | | SO THE OCCUPANTS CAN SEE THE CONTROLLED LIGHTING. | | | A. A CONTROL DEVICE SHALL BE INSTALLED THAT | | | AUTOMATICALLY TURNS LIGHTING OFF WITHIN 30 MINUTES OF | | | ALL OCCUPANTS LEAVING A SPACE, EXCEPT SPACES WITH | | | MULTISCENE CONTROL, IN THE FOLLOWING: | | | 1. CLASSROOMS (NOT INCLUDING SHOP CLASSROOMS, | | | LABORATORY CLASSROOMS, AND PRESCHOOL THROUGH 12TH GRADE | | | CLASSROOMS). | | | 2. CONFERENCE/MEETING ROOMS. | | | 3. EMPLOYEE LUNCH AND BREAK ROOMS. | | | | | | 3}220.14 (G) SHOW WINDOWS. SHOW WINDOWS SHALL BE | | | CALCULATED INACCORDANCE WITH EITHER OF THE FOLLOWING: | | | (1) THE UNIT LOAD PER OUTLET AS REQUIRED IN OTHER | | | PROVISIONS | | | OF THIS SECTION | | | (2) AT 200 VOLT-AMPERES PER 300 MM (1 FT) OF SHOW | | | WINDOW | | | **** LOCATE SAME ON THE PLAN AND IN THE PANEL SCHEDULE | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2010-08-13 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2010-08-13 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2010-08-13 |
Time |
11:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2010-06-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-06-10 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-06-10 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2010-06-10 14:16:41 | *****DENIED***** | | | | | | | | | 1. THE FLOOR PLAN AS SHOWN ON SHEET A.2, MORE REFLECTS | | | THAT OF A BUSINESS OCCUPANCY RATHER THAN A MERCANTILE | | | OCCUPANCY AS INDICATED IN THE PROJECT DATA INFORMATION. | | | | | | 2. ONLY ONE FIRE EXTINGUISHER COULD BE LOCATED. PROVIDE | | | ADDITIONAL FIRE EXTINGUISHER(S) TO SATISFY THE 75' | | | TRAVEL DISTANCE. | | | | | | 3. SPECIFY THE INTERIOR WALL AND CEILING FINISH | | | MATERIALS IN TERMS OF CLASS A, CLASS B, OR CLASS C. | | | SPECIFY INTERIOR FLOOR MATERIAL IN TERMS OF CLASS I OR | | | CLASS II. | | | | | | 4. NO FIRE SPRINKLER HEAD LAYOUT FOR THE NEW FLOOR | | | SHOWN. WILL THE PROJECT'S SCOPE OF WORK HAVE CAUSE FOR | | | THESE DEVICES TO BE RELOCATED / REMODELED ? | | | | | | 5. ON PAGE 1 OF THE FLORIDA ENERGY EFFICIENCY CODE'S | | | PROJECT SUMMARY INFORMATION DOES NOT CORRELATE WITH THE | | | PLAN. FOR EXAMPLE, 1) THE NUMERICAL ADDRESS, 2) | | | OCCUPANCY TYPE, 3) TENANT SPACE NUMBER, 4) SQUARE | | | FOOTAGE OF THE PROJECT | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE/HOW EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-08-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-08-05 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-08-05 |
Time |
12:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-08-04 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-08-02 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-06-07 |
Time |
11:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2010-09-01 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2010-09-01 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2010-08-30 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2010-06-24 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2010-06-24 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2010-06-24 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2010-06-24 15:28:39 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. AC2, WATER SOURCE HEAT PUMP SCHEDULE, FRESH AIR, | | | STATES SEE CALCS. I WAS UNABLE TO LOCATE THE | | | CALCULATIONS REFERENCED ON THE PLAN. PLEASE PROVIDE | | | CALCULATIONS, FBC M 403.2. | | | | | | 2. PROVIDE INFORMATION REGARDING EXHAUST FOR THE TOILET | | | ROOM, FBC M TABLE 403.3. | | | | | | 3. PLEASE INCLUDE THE SYMBOL R (ENCIRCLED) IN THE | | | LEGEND. THIS SYMBOL IS SHOWN AT THE THREE RETURNS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2010-08-10 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-08-10 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-08-09 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2010-08-10 15:15:11 | EXISTING SUITE #1 TYPE M- 91 OCCUPANTS | | | NEW SUITE #2 TYPE M - 134 " | | | TOTA 225 - EXISTING RESTROOMS OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2010-06-23 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-06-23 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-06-23 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2010-06-23 12:44:08 | PLUMBING PLAN REVIEW #1 | | | DENIED: | | | | | | 1. SHEETS A.0, A.3, P-1, P-2 | | | SHEET A.0 LISTS THE AREA AS 4,022 SQUARE FEET. SEPERATE | | | FACILITIES WILL BE REQUIRED FOR EACH SEX. | | | 403.2 SEPARATE FACILITIES. WHERE PLUMBING FIXTURES ARE | | | REQUIRED, SEPARATE FACILITIES SHALL BE PROVIDED FOR | | | EACH SEX. | | | EXCEPTIONS: | | | 1. SEPARATE FACILITIES SHALL NOT BE REQUIRED FOR | | | DWELLING UNITS AND SLEEPING UNITS. | | | 2. SEPARATE FACILITIES SHALL NOT BE REQUIRED FOR FOOD | | | SERVICE ESTABLISHMENTS WHICH SEAT 10 PERSONS OR LESS. | | | 3. SEPARATE FACILITIES SHALL NOT BE REQUIRED IN | | | BUSINESS AND MERCANTILE OCCUPANCIES WITH A TOTAL FLOOR | | | AREA OF 3,000 SQUARE FEET (279 M2) OR LESS. | | | | | | REVIEW BY LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | (561) 805-6692 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2010-08-02 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2010-08-02 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2010-08-02 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|