Plan Review Details - Permit 10060170
| Plan Review Stops For Permit 10060170 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2010-06-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-06-29 |
Time |
08:49 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2010-06-29 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2010-06-29 09:11:05 | BUILDING PLAN REVIEW | | | PERMIT: 10060170 | | | ADD: 2627 OKEECHOBEE BLVD | | | CONT: TO BE DETERMINED | | | TEL: (504)904-8500 REVENUE PROPERTIES WESTWARD, INC | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | | | | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | 1406.2.2 ARCHITECTURAL TRIM- PLEASE PROVIDE ATTACHMENT | | | OF FOAM SHAPED BANDS WITH EFIS FINISH. | | | | | | JIM WITMER C. B. O. | | | COMMERCIAL COMBINATION PLAN REVIEW | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | | CUSTOMER SERVICE SURVEY AT: | | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2010-07-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2010-07-02 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2010-07-02 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2010-07-02 10:31:37 | 2627 OKEECHOBEE BOULEVARD | | | PERMIT NUMBER 10060170 | | | FACADE ENHANCEMENT TO THE OFFICE DEPOT STORE | | | | | | 1. PROTECT INGRESS/EGRESS ROUTES IN AN APPROVED MANNER | | | DURING THE COURSE OF WORK. | | | | | | 2. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. | | | | | | 3. DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. | | | | | | 4. BUILDING ADDRESS NOT SHOWN ON ELEVATION DRAWINGS. A | | | MINIMUM OF AT LEAST 6" HIGH AND 1" WIDE NUMBERS ARE | | | REQUIRED THAT CONTRAST TO THE BACKGROUND THEY ARE | | | AFFIXED TO. | | | | | | APPROVED PROVISO | | | | | | | | | MIKE CARSILLO, BATTALION CHIEF | | | BUREAU OF FIRE PREVENTION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-07-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-07-22 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-07-22 |
Time |
10:21 |
Sent To |
Z |
|
| Notes |
| 2010-07-22 10:21:47 | SENT TO ZONING BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-07-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-07-06 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-06-07 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2010-06-07 11:56:01 | IN ZONING BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2010-07-22 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2010-07-22 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2010-07-22 |
Time |
14:34 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2010-06-10 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2010-06-10 |
Time |
19:42 |
Rev Time |
0.50 |
| Received By |
lfranco |
Date |
2010-06-08 |
Time |
17:12 |
Sent To |
B |
|
| Notes |
| 2010-06-10 19:44:59 | PLANNING AND ZONING: **** FAILED **** | | | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | | | 2. THIS PROPERTY IS PART OF THE WESTWARD SHOPPING | | | CENTER DEVELOPMENT OF SIGNIFICANT IMPACT ("DSI"), | | | THEREFORE, A MINOR DSI IS REQUIRED TO BE SUBMITTED WITH | | | THE PLANNING AND ZONING DEPARTMENT AND APPROVED, PRIOR | | | TO APPROVAL OF THIS PERMIT. | | | | | | ANY WORK PERFORMED WITHOUT FIRST OBTAINING THE MINOR | | | AMENDMENT AND BUILDING PERMIT APPROVAL SHALL BE THE | | | FULL RESPONSIBILITY OF THE OWNER TO RECTIFY AND CORRECT | | | SHOULD IT BE REQUIRED THROUGH OUR REVIEW PROCESS. | | | | | | GO TO HTTP://WWW.CITYOFWPB.COM/PLAN/INDEX.PHP, UNDER | | | DEVELOPMENT APPLICATION FOR REQUIREMENTS OF A MINOR DSI | | | AMENDMENT FOR REQUIREMENTS. | | | | | | 3. PLANS SHALL SHOW THE EXISTING SIGN WITH TOTAL SQUARE | | | FOOTAGE VS. THE PROPOSED SIZE OF THE NEW SIGN. REFER TO | | | THE ZONING CODE, SECTION 94-408(D) SIGNAGE PERMITTED IN | | | GENERAL COMMERCIAL ("GC") - WALL MOUNTED. PROVIDE WHAT | | | IS ALLOWED PER SIZE OF FACADE AND WHAT IS PROPOSED. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] | | | |
|
|
|