Plan Review Details - Permit 10060144
Plan Review Stops For Permit 10060144
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2010-09-02 Cont ID  
Sent By jwitmer Date 2010-09-02 Time 15:58 Rev Time 0.50
Received By jwitmer Date 2010-09-02 Time 15:58 Sent To  
Notes
2010-09-07 09:18:53BUILDING PLAN REVIEW
 PERMIT: 10060144
 ADD: 338 MURRAY RD
 CONT: O/B BROOKS, JAMES
 TEL: (561)685-4340
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING PROVISOS:
  
 1) SHOP DRAWINGS WILL BE REQUIRED FOR BOTH TRUSSES AND
 LINTELS, TRUSS DESIGN MAY VERY FROM THE REVIEWED
 DRAWINGS SHEET 4 OF 5. THE UPLIFT LOADS, LATERAL AND
 GRAVITY LOADS MAY VERY GREATLY THAT WILL EFFECT THE
 BASIC DESIGN AS WELL AS LINTEL DESIGNS. CONTRACTOR /
 OWNER-BUILDER IS PROCEEDING HIS OR HER OWN RISK.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC...
  
 2) FLAT ROOF:
 FL1654-R4
 POLYGLASS- MODIFIED BITUMEN ROOF SYSTEMS
 APPENDIX1, PAGE 10 OF 33
 W-26 SYSTEM -60.0 PSF
 ZONES 2 & 3 REQUIRE ENHANCED FASTENING
 LIMITATION 5.6 DOES ALLOW ENHANCED FASTENING IN ZONES
 2&3 BY A QUALIFIED DESIGN PROFESSIONAL.
 TO BE PROVIDED AT TIME OF ROOFING PERMIT APPLICATION.
  
 METAL ROOF:
 FL 11698
 ENGLERT INC.
 DESIGN UPLIFT OF -124 PSF. C-BUCK ENGINEERING PRODUCT
 APPROVAL.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2010-08-19 Cont ID  
Sent By jwitmer Date 2010-08-19 Time 12:16 Rev Time 4.00
Received By jwitmer Date 2010-08-19 Time 08:54 Sent To  
Notes
2010-08-19 13:13:37BUILDING PLAN REVIEW
 PERMIT: 10060144
 ADD: 338 MURRAY RD
 CONT: O/B BROOKS, JAMES
 TEL: (561)685-4340
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 AUGUST 19/ 2010
 2ND REVIEW
 ACTION: DENIED
  
 1) PLEASE PROVIDE SIGNED AND SEALED SOILS REPORTS (2).
 1802.2.1 QUESTIONABLE SOIL. WHERE THE SAFE-SUSTAINING
 POWER OF THE SOIL IS IN DOUBT, OR WHERE A LOAD-BEARING
 VALUE SUPERIOR TO THAT SPECIFIED IN THIS CODE IS
 CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE THAT THE
 NECESSARY INVESTIGATION BE MADE. SUCH INVESTIGATION
 SHALL COMPLY WITH THE PROVISIONS OF SECTIONS 1802.4
 THROUGH 1802.6 .
  
 BUILDING PROVISOS:
  
 1) SHOP DRAWINGS WILL BE REQUIRED FOR BOTH TRUSSES AND
 LINTELS, TRUSS DESIGN MAY VERY FROM THE REVIEWED
 DRAWINGS SHEET 4 OF 5. THE UPLIFT LOADS, LATERAL AND
 GRAVITY LOADS MAY VERY GREATLY THAT WILL EFFECT THE
 BASIC DESIGN AS WELL AS LINTEL DESIGNS. CONTRACTOR /
 OWNER-BUILDER IS PROCEEDING HIS OR HER OWN RISK.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC...
  
 2) FLAT ROOF:
 FL1654-R4
 POLYGLASS- MODIFIED BITUMEN ROOF SYSTEMS
 APPENDIX1, PAGE 10 OF 33
 W-26 SYSTEM -60.0 PSF
 ZONES 2 & 3 REQUIRE ENHANCED FASTENING
 LIMITATION 5.6 DOES ALLOW ENHANCED FASTENING IN ZONES
 2&3 BY A QUALIFIED DESIGN PROFESSIONAL.
 TO BE PROVIDED AT TIME OF ROOFING PERMIT APPLICATION.
  
 METAL ROOF:
 FL 11698
 ENGLERT INC.
 DESIGN UPLIFT OF -124 PSF. C-BUCK ENGINEERING PRODUCT
 APPROVAL.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-06-30 Cont ID  
Sent By jwitmer Date 2010-06-29 Time 16:31 Rev Time 0.00
Received By jwitmer Date 2010-06-30 Time 09:00 Sent To  
Notes
2010-06-29 16:49:55BUILDING PLAN REVIEW
 PERMIT: 10060144
 ADD: 338 MURRAY RD
 CONT: O/B BROOKS, JAMES
 TEL: (561)685-4340
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PLEASE PROVIDE SIGNED AND SEALED SOILS REPORTS (2).
 1802.2.1 QUESTIONABLE SOIL. WHERE THE SAFE-SUSTAINING
 POWER OF THE SOIL IS IN DOUBT, OR WHERE A LOAD-BEARING
 VALUE SUPERIOR TO THAT SPECIFIED IN THIS CODE IS
 CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE THAT THE
 NECESSARY INVESTIGATION BE MADE. SUCH INVESTIGATION
 SHALL COMPLY WITH THE PROVISIONS OF SECTIONS 1802.4
 THROUGH 1802.6 .
  
 2) SHEET 4 OF 5 TRUSS LAYOUT SHEET DOES NOT PROVIDE THE
 UPLIFT, LATERAL OR GRAVITY LOADS TO BE RESISTED.
 FBC-R802.1.6.5 TRUSS TO WALL CONNECTIONS. THE PLANS
 ONLY INDICATE A HETAL 20 WOULD THIS CONNECTION BE USED
 FOR GIRDER TO WALL CONNECTIONS AS WELL?
  
 3) SHEET 2 OF 5 INDICATES A ROOF PRESSURE SCHEDULE WITH
 ONLY ONE SET OF VALUES. IS THIS VALUE FOR THE 6:12 ROOF
 OR THE FLAT ROOF? WE WILL NEED THE POSITIVE AND
 NEGATIVE PRESSURES FOR BOTH. THE CHARTS TO USE WILL BE
 THE 10 SQ FT SINCE THIS IS FOR COMPONENTS AND CLADDING.
 FBC- TABLE R.301.2(2).
  
 4) PLANS FAIL TO INDICATE COMPLIANCE WITH SEPARATION
 BETWEEN THE GARAGE AND HABITABLE AREAS OF THE
 RESIDENCE.
 406.1.4 SEPARATION. SEPARATIONS SHALL COMPLY WITH THE
 FOLLOWING:
 1. THE PRIVATE GARAGE SHALL BE SEPARATED FROM THE
 DWELLING UNIT AND ITS ATTIC AREA BY MEANS OF A MINIMUM
 1/2-INCH (12.7 MM) GYPSUM BOARD APPLIED TO THE GARAGE
 SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE
 SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS
 THAN A 5/8-INCH TYPE X GYPSUM BOARD OR EQUIVALENT. DOOR
 OPENINGS BETWEEN A PRIVATE GARAGE AND THE DWELLING UNIT
 SHALL BE EQUIPPED WITH EITHER SOLID WOOD DOORS OR SOLID
 OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 13/8 INCHES
 (34.9 MM) THICK, OR DOORS IN COMPLIANCE WITH SECTION
 715.4.3. OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A
 ROOM USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED.
 DOORS SHALL BE SELF-CLOSING AND SELF-LATCHING.
 2. DUCTS IN A PRIVATE GARAGE AND DUCTS PENETRATING THE
 WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE
 GARAGE SHALL BE CONSTRUCTED OF A MINIMUM 0.019-INCH
 (0.48 MM) SHEET STEEL AND SHALL HAVE NO OPENINGS INTO
 THE GARAGE.
 3. A SEPARATION IS NOT REQUIRED BETWEEN A GROUP R-3 AND
 U CARPORT, PROVIDED THE CARPORT IS ENTIRELY OPEN ON TWO
 OR MORE SIDES AND THERE ARE NOT ENCLOSED AREAS ABOVE.
  
 5) SHEET 3 OF 5 INDICATES (3) 3INCH VERTICAL PLUMBING
 RISERS, ARE THEY TO BE BUILT OUTSIDE OF THE MASONRY
 WALL OR ARE THEY TO BE PLACED WITHIN THE MASONRY WALL?
 106.1.2 ADDITIONAL INFORMATION REQUIRED 106.1.2.
  
 6) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE
 REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 7) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING,
 PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING
 REPORTS ARE AS FOLLOWS:
 7A) PGT SERIES FD-750 OUTSWING ALUMINUM FRENCH DOORS
 NOA 07-0103.02 IS EXPIRED AS OF FEB. 24/ 2010
 7B) PGT SERIES PW-701 ALUMINUM FIXED WINDOWS NOA
 07-0418.06 IS EXPIRED FEB 19, 2009
 7C) ROOFING POLYGLASS FL COVER SHEET FL985-R1 SUBMITTED
 WITH ENGLERT METAL ROOFING REPORT AS BACK UP REPORT.
 PLEASE SUBMIT THE PROPER POLYGLASS REPORT CIRCLE WHICH
 SUB-SYSTEM TO BE INSTALLED.
 7D) ENGLERT METAL ROOF FL# 6558 PLEASE HIGHLIGHT
 (CIRCLE) WHICH SUB-SYSTEM TO BE INSTALLED DEPENDING ON
 SELECTION, IT MAY REQUIRE ENHANCED FASTENING.
 7E) ROOFING FLAT DECK- MAY REQUIRE A DIFFERENT REPORT
 FROM THE POLYGLASS DEPENDING ON SELECTION.
 7F) LINTELS- WITH THE NEW WALL HEIGHT OF 9???-4??? IT
 WOULD APPEAR A LINTEL WILL BE REQUIRED, PLEASE
 HIGHLIGHT (CIRCLE LINTEL TO BE INSTALLED.
  
 8) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 NOTE OF CAUTION: PLANS INDICATE FUTURE POOL, THE
 FOOTERS FOR THE BACK PORCH MAY BE OF CONCERN WHEN THE
 POOL IS BEING DUG & INSTALLED PLEASE BE AWARE OF
 R403.1.7.2.
  
 INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES
 DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER
 NOTICE.
  
 OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM
 - 5:00 PM.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-06-22 Cont ID  
Sent By btrobaug Date 2010-06-22 Time 10:59 Rev Time 0.00
Received By btrobaug Date 2010-06-22 Time 10:28 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2010-09-02 Cont ID  
Sent By jwitmer Date 2010-09-02 Time 16:00 Rev Time 0.00
Received By jwitmer Date 2010-09-02 Time 14:51 Sent To  
Notes
2010-09-02 14:53:209/02/2010 GAS TO BE REVIEWED UNDER A SEPERATE PERMIT
 WITH ASSOCIATED PLANS, MANUFACTURERS SPECS & FEES.
 JWITMER

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-08-11 Cont ID  
Sent By shill Date 2010-08-11 Time 13:23 Rev Time 0.00
Received By shill Date 2010-08-11 Time 13:21 Sent To  
Notes
2010-08-11 13:24:06R10
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-07-14 Cont ID  
Sent By rmcdouga Date 2010-07-14 Time 15:42 Rev Time 0.00
Received By rmcdouga Date 2010-06-07 Time 09:28 Sent To  
Notes
2010-06-07 09:29:15R-6

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2010-09-02 Cont ID  
Sent By jwitmer Date 2010-09-02 Time 15:59 Rev Time 0.00
Received By jwitmer Date 2010-09-02 Time 15:59 Sent To  
Notes
2010-09-02 15:59:56MU-2010-016387-0000
 FEES $ 2,347.26

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2010-06-29 Cont ID  
Sent By jwitmer Date 2010-06-29 Time 16:30 Rev Time 0.00
Received By jwitmer Date 2010-06-29 Time 16:30 Sent To  
Notes
2010-06-29 16:31:15BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
  

Review Stop L LANDSCAPING
Rev No 3 Status N Date 2010-09-02 Cont ID  
Sent By shill Date 2010-09-02 Time 16:08 Rev Time 0.00
Received By shill Date 2010-09-02 Time 16:08 Sent To  
Notes
2010-09-02 16:09:41PER DW, PERMIT CAN BE ISSUED UPON SUBMITTAL OF
 LANDSCAPE/IRRIGATION PERMIT APPLICATIONS -
  
 LANDSCAPE 10090073
 IRRIGATION 10090072
  
  

Review Stop L LANDSCAPING
Rev No 2 Status F Date 2010-08-23 Cont ID  
Sent By rkussner Date 2010-08-23 Time 16:28 Rev Time 0.00
Received By rkussner Date 2010-08-23 Time 16:28 Sent To  
Notes
2010-08-23 16:29:25***LANDSCAPE REVIEW FAILED***
  
 1. REPEAT COMMENT: PLEASE APPLY FOR A SEPARATE
 IRRIGATION PERMIT AND SUBMIT TWO COPIES OF THE
 IRRIGATION PLAN. THE SYSTEM SHALL HAVE A RAIN SENSING
 DEVICE.
  
 2. REPEAT COMMENT: APPLY FOR A SEPARATE LANDSCAPE
 PERMIT. SUBMIT TWO COPIES OF THE LANDSCAPE PLAN AND A
 COST ESTIMATE THAT INCLUDES THE TOTAL COST OF ALL
 LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO UNIT
 COST.
  
 3. REPEAT COMMENT: ALL PROPOSED TREES AND PALMS SHALL
 COMPLY WITH FPL'S "PLANT THE RIGHT TREE IN THE RIGHT
 PLACE" GUIDELINES THAT SPECIFIES WHICH TREE SPECIES CAN
 BE PLANTED NEAR OR UNDER POWER LINES.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2010-06-11 Cont ID  
Sent By rkussner Date 2010-06-11 Time 12:32 Rev Time 0.00
Received By rkussner Date 2010-06-11 Time 12:32 Sent To  
Notes
2010-06-11 13:04:40***LANDSCAPE REVIEW FAILED***
  
 1. PLEASE APPLY FOR A SEPARATE IRRIGATION PERMIT AND
 SUBMIT TWO COPIES OF THE IRRIGATION PLAN. THE SYSTEM
 SHALL HAVE A RAIN SENSING DEVICE.
  
 2. APPLY FOR A SEPARATE LANDSCAPE PERMIT. SUBMIT TWO
 COPIES OF THE LANDSCAPE PLAN AND A COST ESTIMATE THAT
 INCLUDES THE TOTAL COST OF ALL LANDSCAPE MATERIALS AND
 LABOR, BROKEN DOWN INTO UNIT COST.
  
 3. ALL PROPOSED TREES AND PALMS SHALL COMPLY WITH FPL'S
 "PLANT THE RIGHT TREE IN THE RIGHT PLACE" GUIDELINES
 THAT SPECIFIES WHICH TREE SPECIES CAN BE PLANTED NEAR
 OR UNDER POWER LINES.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2010-06-30 Cont ID  
Sent By jwitmer Date 2010-06-30 Time 14:47 Rev Time 0.50
Received By jwitmer Date 2010-06-30 Time 14:47 Sent To  
Notes
2010-06-30 14:50:58BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S).
 GAS TANKLESS WATERHEATER EXTERIOR LOCATION, PLEASE
 PROVIDE MANUFACTURERS SPECIFICATION INDICATING HOW
 CLOSE THIS UNIT CAN BE LOCATED WITHIN, OPENINGS, DOORS,
 WINDOWS AND CONTINIOUS EAVE VENTS.

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-06-30 Cont ID  
Sent By jwitmer Date 2010-06-30 Time 14:51 Rev Time 0.55
Received By jwitmer Date 2010-06-30 Time 14:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2010-07-14 Cont ID  
Sent By astelly Date 2010-07-14 Time 08:29 Rev Time 0.00
Received By astelly Date 2010-07-14 Time 08:37 Sent To  
Notes
2010-07-14 08:39:01AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 PASSED W/ PROVISO
  
 ALL LANDSCAPE COMMENTS MUST BE SATISFIED.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved