Plan Review Details - Permit 10060139
| Plan Review Stops For Permit 10060139 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-07-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-07-20 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-07-20 |
Time |
15:39 |
Sent To |
E |
|
| Notes |
| 2010-07-20 15:46:28 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. REVISE EXPOSURE CATEGORY OR ENGINEERING FOR EXPOSURE | | | B AS THIS PARCEL IS LOCATED IN A TRANSITION ZONE. | | | FBC1609, FBC R301.2.1.4. NOTE THAT THE CODE CHANGED | | | EFFECTIVE MARCH 1, 2009. | | | | | | 2. FBC*106, FBC R301, THE BLOCK FOOTER IS SHOWN AS | | | SITTING ON SOMETHING WHICH IS GRAPHICALLY SHOWN | | | DIFFERENTLY THAN THE DIRT. PLEASE SPECIFY. THE TEXT | | | "FILL BLOCKS WITH SAXCRETE" (SIC) APPEARS TO POINT TO | | | THIS AREA AS WELL AS THE BLOCK. PLEASE REVISE PLAN TO | | | MAKE DESIGN INTENT CLEAR. | | | | | | 3. BOND BREAK REQUIRED FBC R 703.6.3. | | | | | | 4. PROVIDE A SITE PLAN WHICH SHOWS THE PROPOSED | | | IMPROVEMENT IN RELATION TO LOT LINES AND OTHER | | | STRUCTURES ON THE PARCEL. | | | | | | 5. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR | | | THE DOOR, WINDOW, AND ROOF, FAC9B72. | | | | | | 7. ENGINEER'S SEAL IS TO INCLUDE A DATE, FS471. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2010-07-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-07-21 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-07-21 |
Time |
07:26 |
Sent To |
|
|
| Notes |
| 2010-07-21 07:31:34 | DENIED/INCOMPLETE INFORMATION | | | | | | THE APPLICATION INDICATES HAS AN ELECTRICAL CONTRACTOR | | | SIGNED ON, BUT NO ELECTRICAL PLANS WERE SUBMITTED. | | | SUBMIT PLANS INDICATING THE SCOPE OF WORK, OR REMOVE | | | THE ELECTRICAL WORK FROM THE APPLICATION. 106.1 FBC AS | | | AMENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-07-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-07-20 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-06-04 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2010-06-04 10:58:38 | IN ZONING BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2010-06-09 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2010-06-09 |
Time |
18:45 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2010-06-08 |
Time |
16:48 |
Sent To |
B |
|
| Notes |
| 2010-06-09 18:48:13 | PLANNING AND ZONING: **** FAILED **** | | | | | | | | | 1. RESPOND TO COMMENTS IN WRITING. THE SUBMITTAL OF THE | | | REQUESTED INFORMATION MAY GENERATE ADDITIONAL COMMENTS. | | | | | | | | | 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | | INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION. | | | PROVIDE DIMENSIONS OF STORAGE BUILDING FROM ALL | | | PROPERTY LINES. | | | | | | | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] | | | | | | | | | | | | | | | |
|
|
|