Plan Review Details - Permit 10060051
| Plan Review Stops For Permit 10060051 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-06-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-06-21 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-06-21 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2010-06-21 10:04:25 | ****PROVISO**** | | | ****ISSUED AT CONTRACTOR'S RISK**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. EXPOSURE CATEGORY C DESIGN PRESSURES REQUIRED. | | | FBC1609, FBC R301.2.1.4. NOTE THAT THE CODE CHANGED | | | EFFECTIVE MARCH 1, 2009. PRESSUES SUBMITTED ARE TOO LOW | | | BUT ANCHOR SPACING APPEARS TO BE COMPLIANT. | | | | | | 2. SHUTTER MOUNTING CONNECTION TYPE WAS NOT COMPLETED | | | ON THE INSTALLATION SCHEDULE. PLEASE SEE PAGE 11 OF THE | | | PRODUCT APPROVAL. IF C1 OR C2 ARE USED, 12" SPACING | | | COMPLIES. IF ANOTHER MOUNTING TYPE IS USED, REVISION | | | REQUIRED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-06-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-06-08 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-06-08 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2010-06-08 10:06:31 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF | | | | | | 2. PLEASE PRINT THE FLORIDA STATE PRODUCT APPROVAL | | | COVER SHEET WHICH SHOWS APPROVAL NUMBER AND STATUS, | | | FAC9B72. THIS IS AVAILABLE AT WWW.FLORIDABUILDING.ORG. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-06-15 |
|
|
Cont ID |
|
| Sent By |
vmolina |
Date |
2010-06-15 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
vmolina |
Date |
2010-06-15 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2010-06-15 10:20:33 | GAVE TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-06-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-06-08 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-06-02 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2010-06-02 09:53:16 | UNDER 5K BUILDING |
|
|
|