| Plan Review Stops For Permit 10050638 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2011-01-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-01-18 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-01-18 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2011-01-18 11:52:49 | OWNER WANTS TO REMOVE THE NEW GARAGE APARTMENT IN THE | | | REAR FROM THE SCOPE OF WORK. VALUE OF THE WORK FOR THE | | | MAIN HOUSE IS $38,000.00. THE PERMIT FEES WILL ADJUSTED | | | ACCORDINGLY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2011-01-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-01-10 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-01-10 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2011-01-10 11:35:46 | PROPOSED WORK FOR MAIN HOUSE IS OK. EXCEPT THAT THE | | | OWNER/AGENT NEEDS TO SIGN THE ENERGY CALCULATIONS. NEED | | | CLARIFICATION FOR R-VALUES FOR WALLS AND CEILING THAT | | | DIFFER ON PLANS AND ENERGY CALCS. | | | | | | COMMENTS FOR NEW GARAGE APARTMENT HAVE NOT BEEN | | | ADDRESSED. A LETTER FROM OWNER WAS SUBMITTED STATING | | | THAT THE GARAGE APARTMENT WILL NOT BE BUILT AT THIS | | | TIME. THE VALUE OF THE WORK WILL NEED TO BE ADJUSTED TO | | | REFLECT THE NEW SCOPE OF WORK EXCLUDING THE GARAGE | | | APARTMENT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2010-12-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-12-20 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-12-20 |
Time |
08:11 |
Sent To |
|
|
| Notes |
| 2010-12-20 08:57:21 | 2007 FBC W/2009 REVISIONS (2ND REVIEW) | | | | | | A) MAIN HOUSE | | | | | | DENIED BY BUILDING | | | | | | 1) SUBMIT A COPY OF THE PAID RECEIPT FOR THE COUNTY | | | IMPACT FEES (MU2010-21526) AS REQUESTED IN FIRST | | | REVIEW. | | | | | | 2) THE ENERGY CALC. FORM IS REQUIRED TO BE SIGNED BY | | | THE OWNER/AGENT. THE INSULATION R VALUES LISTED ON THE | | | FORM DO NOT MATCH THE ONES SPECIFIED ON THE WALL | | | SECTION ON SHEET 3 OF THE PLANS. PLEASE CORRECT. REPEAT | | | COMMENT. | | | | | | 3) SUBMIT 2 SETS OF PRODUCT APPROVALS FOR THE ROOF | | | SHINGLES, TRUSS CONNECTORS AND STRAPS AS REQUIRED BY | | | DCA RULE 9B-72. REPEAT COMMENT. | | | | | | 4) SHEET T-1 STILL SPECIFIES EXPOSURE CATEGORY B. | | | PLEASE CHANGE TO EXPOSURE CATEGORY C AND REVIEW | | | CONNECTOR DESIGN UPLIFTS. | | | | | | | | | B) NEW GARAGE/ APARTMENT | | | | | | DENIED BY BUILDING | | | | | | 1) A SEPARATE APPLICATION WITH SEPARATE PERMIT NUMBERS | | | WILL BE REQUIRED FOR THE GARAGE / APARTMENT. REPEAT | | | COMMENT. THE ADDRESS FOR THE GARAGE APARTMENT IS 1120 | | | FLORIDA AVE. | | | | | | 2) SUBMIT COPY OF PAID RECEIPT FOR IMPACT FEES. REPEAT | | | COMMENT. | | | | | | 3) SUBMIT 2 SETS OF ENERGY CALCULATIONS FOR THE GARAGE | | | APARTMENT. REPEAT COMMENT. | | | | | | 4) ADJUST THE CORRESPONDING WIND-LOAD PRESSURES | | | ACCORDINGLY. SEE FBC R 301.2.1.4.3. PLEASE REVISE THE | | | SPECIFIED COMPONENT AND CLADDING PRESSURES ON SHEET 1 | | | TO REFLECT THE CHANGE TO EXPOSURE C WITH A MEAN ROOF | | | HEIGHT OF MORE THAN 20 FEET. SHEET 2 STILL SPECIFIES | | | EXPOSURE B UNDER THE DESIGN CRITERIA. PLEASE CHANGE TO | | | EXPOSURE CATEGORY C AND REVIEW CONNECTOR SCHEDULE FOR | | | ADEQUATE UPLIFT RESISTANCE. REPEAT COMMENT. | | | | | | 5) SUBMIT 2 SETS OF PRODUCT APPROVALS FOR THE ROOF | | | COVERING, SLIDING GLASS DOOR, EXTERIOR OUTSWING DOORS, | | | SECTIONAL GARAGE DOOR AS REQUIRED BY DCA RULE 9B-72. | | | REPEAT COMMENT. | | | | | | 6) ONLY ONE SET OF REVISED PLANS WAS SUBMITTED FOR THE | | | GARAGE APARTMENT. | | | | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-06-24 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-06-23 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2010-06-23 14:18:37 | 2007 FBC W/2009 REVISIONS | | | | | | A) MAIN HOUSE | | | | | | DENIED BY BUILDING | | | | | | 1) BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. 233-5025 | | | | | | 2) THE EXPOSURE CATEGORY IS INCORRECTLY SPECIFIED ON | | | THE PLANS AS EXPOSURE B AND IT SHOULD BE C. PLEASE | | | CORRECT AND ADJUST THE CORRESPONDING WIND-LOAD | | | PRESSURES ACCORDINGLY. SEE FBC R 301.2.1.4.3. | | | | | | 3) THE ENERGY CALC. FORM IS REQUIRED TO BE SIGNED BY | | | THE OWNER/AGENT. THE INSULATION R VALUES LISTED ON THE | | | FORM DO NOT MATCH THE ONES SPECIFIED ON THE WALL | | | SECTION ON SHEET 3 OF THE PLANS. PLEASE CORRECT. | | | | | | 4) THE MASONRY FOUNDATION STEM WALLS ARE REQUIRED TO | | | HAVE VERTICAL REINFORCEMENT PER FBC R404.1.1. SPECIFY | | | THE SIZE AND SPACING OF THE VERTICAL REINFORCING. | | | | | | 5) SUBMIT 2 SETS OF PRODUCT APPROVALS FOR THE ROOF | | | SHINGLES, TRUSS CONNECTORS AND STRAPS AS REQUIRED BY | | | DCA RULE 9B-72. | | | | | | 6) SHOW COMPLIANCE WITH FBC R807.1 FOR ATTIC ACCESS. | | | | | | | | | | | | B) NEW GARAGE/ APARTMENT | | | | | | DENIED BY BUILDING | | | | | | 1) A SEPARATE APPLICATION WITH SEPARATE PERMIT NUMBERS | | | WILL BE REQUIRED FOR THE GARAGE / APARTMENT. | | | | | | 2) THE GARAGE APARTMENT WILL BE REQUIRED TO HAVE AN | | | ADDRESS FOR THE BUILDING. CONTACT JOHN NGUYEN AT (561) | | | 822-1239. | | | | | | 3) BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. 233-5025 | | | | | | 4) SUBMIT 2 SETS OF ENERGY CALCULATIONS FOR THE GARAGE | | | APARTMENT. | | | | | | 5) THE EXPOSURE CATEGORY IS INCORRECTLY SPECIFIED ON | | | THE PLANS AS EXPOSURE B AND IT SHOULD BE C. PLEASE | | | CORRECT AND ADJUST THE CORRESPONDING WIND-LOAD | | | PRESSURES ACCORDINGLY. SEE FBC R 301.2.1.4.3. | | | | | | 6) SPECIFY THE SIZE AND LOCATION OF THE ATTIC ACCESS | | | REQUIRED BY FBC R807.1. | | | | | | 7) SPECIFY THE SIZE AND SPACING OF THE FLOOR JOISTS AT | | | THE WOOD DECK. | | | | | | 8) THE SIMPSON LCB44 SPECIFIED ON SHEET E1 AT THE BASE | | | OF THE 6 X 6 POSTS IS FOR 4 X 4 POSTS. THE LCB66 IS FOR | | | 6 X 6 POSTS. | | | | | | 9) SHOW THAT STAIRS COMPLY WITH FBC R 311.5.1 FOR 36" | | | MINIMUM CLEAR WIDTH. | | | | | | 10) SHOW COMPLIANCE WITH FBC R 311.5.6.1 THROUGH | | | 311.5.6.3 FOR HANDRAIL REQUIREMENTS AT THE EXTERIOR | | | STAIRS. | | | | | | 11) SUBMIT 2 SETS OF PRODUCT APPROVALS FOR THE ROOF | | | COVERING, SLIDING GLASS DOOR, EXTERIOR OUTSWING DOORS, | | | SECTIONAL GARAGE DOOR AS REQUIRED BY DCA RULE 9B-72. | | | | | | 12) SHOW COMPLIANCE WITH FBC R309.2 GARAGES BENEATH | | | HABITABLE ROOMS SHALL BE SEPARATED BY NOT LESS THAN | | | 5/8-INCH TYPE X GYPSUM BOARD OR EQUIVALENT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-06-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-06-21 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-06-16 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-12-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-12-28 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-12-28 |
Time |
13:59 |
Sent To |
B |
|
| Notes |
| 2010-12-28 14:00:25 | SENT TO R. MCDOUGAL'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-06-24 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-05-20 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2010-05-24 11:30:11 | TO R16 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2011-01-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-01-10 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-01-10 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2011-01-10 11:30:14 | MU-2010-021526-0000 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2010-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-06-22 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-06-22 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2010-06-22 08:27:20 | IMPACT FEE REVIEW BY PALM BEACH COUNTY IS REQUIRED FOR | | | BOTH STRUCTURES. | | | | | | COPY OF PAID RECEIPT FOR IMPACT FEES IS REQUIRED |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
N |
Date |
2011-01-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-12-20 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-12-20 |
Time |
12:20 |
Sent To |
|
|
| Notes |
| 2010-12-20 12:23:58 | A SEPARATE PERMIT AND PLANS ARE REQUIRED FOR | | | LANDSCAPING. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
2010-12-13 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2010-12-13 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2010-12-13 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2010-12-13 12:12:19 | ***LANDSCAPE REVIEW FAILED*** | | | | | | PLEASE RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT. | | | | | | 1. REPEAT COMMENT: PURSUANT TO SECTION 94-441(C)(2) OF | | | THE ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR): AS | | | THE VALUE OF THE PROPOSED WORK EXCEEDS 50% OF THE | | | STRUCTURE'S VALUE (LISTED AS "IMPROVEMENT VALUE" WITH | | | THE P.B.C. PROPERTY APPRAISER'S OFFICE), LANDSCAPING | | | SHALL BE IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS | | | FOUND IN ARTICLE XIV OF THE ZLDR. | | | | | | 2. REPEAT COMMENT: PLEASE APPLY FOR A LANDSCAPE PERMIT | | | AND SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN SHOWING | | | COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF THE ZLDR. | | | SUBMIT A COST ESTIMATE THAT INCLUDES THE TOTAL COST OF | | | ALL LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO | | | UNIT COST. | | | | | | 3. REPEAT COMMENT: PLEASE PROVIDE THE TABULATION | | | NECESARY FOR THE EVALUATION OF COMPLIANCE WITH ARTICLE | | | XIV OF THE ZONING AND LAND DEVELOPMENT REGULATIONS, | | | INCLUDING XERISCAPE DESIGN OPTIONS. | | | | | | 4. REPEAT COMMENT: IRRIGATION REQUIRES A SEPARATE | | | PERMIT. THE AUTOMATED SYSTEM SHALL PROVIDE 120% | | | COVERAGE TO ALL LANDSCAPED AREAS, INCLUDING | | | RIGHTS-OF-WAY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2010-05-26 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2010-05-26 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2010-05-26 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2010-05-26 12:02:11 | ***LANDSCAPE REVIEW FAILED*** | | | | | | PLEASE RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT. | | | | | | 1. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF | | | THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE | | | (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | | THE ZLDR. | | | | | | 2. PLEASE APPLY FOR A LANDSCAPE PERMIT AND SUBMIT TWO | | | (2) COPIES OF A LANDSCAPE PLAN SHOWING COMPLIANCE WITH | | | SECTIONS 94-442 AND 94-445 OF THE ZLDR. SUBMIT A COST | | | ESTIMATE THAT INCLUDES THE TOTAL COST OF ALL LANDSCAPE | | | MATERIALS AND LABOR, BROKEN DOWN INTO UNIT COST. | | | | | | 3. PLEASE PROVIDE THE TABULATION NECESARY FOR THE | | | EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING | | | AND LAND DEVELOPMENT REGULATIONS, INCLUDING XERISCAPE | | | DESIGN OPTIONS. | | | | | | 4. IRRIGATION REQUIRES A SEPARATE PERMIT. THE AUTOMATED | | | SYSTEM SHALL PROVIDE 120% COVERAGE TO ALL LANDSCAPED | | | AREAS, INCLUDING RIGHTS-OF-WAY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2011-01-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-01-18 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-01-18 |
Time |
13:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2010-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-06-22 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-06-22 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2010-06-22 13:49:56 | 2007 FBC W/2009 REVISIONS | | | | | | A) MAIN HOUSE | | | | | | MECHANICAL DENIED | | | | | | 1) SUBMIT 2 COPIES OF THE HVAC PLAN. PLANS ARE REQUIRED | | | TO BE A MINIMUM OF 1/8" SCALE. THE PLANS THAT WERE | | | SUBMITTED ARE TOO SMALL. CITY AMENDMENTS 106.1.3 | | | | | | 2) FBC R M1602.2 DOES NOT ALLOW RETURN AIR TO BE TAKEN | | | FROM THE KITCHEN. PLEASE REVISE PLANS. | | | | | | | | | B) GARAGE/APARTMENT | | | | | | NO MECHANICAL PLANS OR CALCULATIONS WERE SUBMITTED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2010-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-06-22 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-06-22 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2010-06-22 10:24:08 | PLUMBING FOR MAIN HOUSE AND GARAGE APARTMENT ARE OK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2010-06-14 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2010-06-14 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2010-06-14 |
Time |
11:09 |
Sent To |
B |
|
| Notes |
| 2010-06-14 11:36:11 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | PASSED W/PROVISO | | | | | | A LANDSCAPE PLAN MUST BE SUBMITTED FOR REVIEW. |
|
|