Plan Review Details - Permit 10050509
Plan Review Stops For Permit 10050509
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-06-17 Cont ID  
Sent By rmcdouga Date 2010-06-17 Time 10:23 Rev Time 0.00
Received By rmcdouga Date 2010-06-17 Time 10:23 Sent To  
Notes
2010-06-17 10:30:39TWO SETS OF PRODUCT APPROVALS ARE REQUIRED TO BE
 SUBMITTED FOR THE 9' WIDE GARAGE DOORS AND THE VINYL
 CLAD WINDOWS THAT WERE CHANGED IN THE REVISION. (REV
 #6)

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-05-28 Cont ID  
Sent By btrobaug Date 2010-05-28 Time 11:04 Rev Time 0.00
Received By btrobaug Date 2010-05-28 Time 10:32 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2010-09-13 Cont ID  
Sent By rmcdouga Date 2010-09-13 Time 13:15 Rev Time 0.00
Received By rmcdouga Date 2010-09-13 Time 13:15 Sent To  
Notes
2010-09-13 14:12:542004 FBC
 REVISION
 SHEET P2
  
 GAS REVIEW
 REVISION REQUIRED
  
 ON SHEET P-2.0, THE TOTAL DEVELOPED GAS PIPE LENGTH
 FROM METER TO FURTHEST APPLIANCE IS 165' - 9" NOT 127'
 - 1" AND THE TOTAL LENGTH OF ALL PIPING IS 228' - 6"
 NOT 189' - 9". THESE DIFFERENCES REQUIRE 1-1/2" PIPE
 FROM THE METER TO THE FIRST BRANCH AND 1 - 1/4" PIPE
 FROM FIRST BRANCH TO THE SECOND BRANCH. SEE REDLINES ON
 DENIED PLANS. SUBMIT A SEPARATE GAS PERMIT WITH TWO
 SETS OF REVISED GAS ISOMETRIC DRAWINGS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2010-06-16 Cont ID  
Sent By rmcdouga Date 2010-06-16 Time 15:35 Rev Time 0.00
Received By rmcdouga Date 2010-06-16 Time 15:35 Sent To  
Notes
2010-06-16 15:43:082004 FBC
 REVISION
 SHEET P2
  
 GAS REVIEW DENIED
  
 1) THE GAS PIPE SIZING IS NOT ADEQUATE. FBC P 402.1
  
 2) SEPARATE GAS PERMIT AND GAS ISOMETRIC DRAWINGS ARE
 REQUIRED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-08-25 Cont ID  
Sent By lmartine Date 2010-08-25 Time 11:01 Rev Time 0.00
Received By lmartine Date 2010-08-25 Time 11:01 Sent To  
Notes
2010-08-25 11:02:05IN ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-06-17 Cont ID  
Sent By rmcdouga Date 2010-06-17 Time 10:23 Rev Time 0.00
Received By rmcdouga Date 2010-05-20 Time 15:32 Sent To  
Notes
2010-05-20 15:36:12SENT TO R-9.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2010-06-17 Cont ID  
Sent By rmcdouga Date 2010-06-17 Time 10:23 Rev Time 0.00
Received By rmcdouga Date 2010-06-17 Time 10:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-06-16 Cont ID  
Sent By rmcdouga Date 2010-06-16 Time 15:43 Rev Time 0.00
Received By rmcdouga Date 2010-06-16 Time 15:43 Sent To  
Notes
2010-06-16 15:44:50REVISED PLUMBING ON SHEET P-1 IS CODE COMPLIANT.

Review Stop Z ZONING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2010-09-01 Cont ID  
Sent By jroach Date 2010-09-01 Time 09:30 Rev Time 0.00
Received By jroach Date 2010-08-27 Time 14:34 Sent To G
Notes
2010-09-01 09:32:32ZONING PLAN REVIEW
  
 PERMIT NO.: 08070580
 ADDRESS: 203 ALPINE ROAD
 CONTRACTOR/CONTACT: JEFF CONTE
 TELEPHONE NO.: 561.324.8055
 SCOPE OF REVIEW: REVISIONS TO PROPOSED RESIDENTIAL
 ADDITION.
  
 REVIEW STATUS: FAILED
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1) REPEAT COMMENT: SHEET A-2.3 INDICATES THE ADDITION
 OF AN EXTERIOR STAIRCASE TO THE 2ND FLOOR OF THE
 GARAGE...THIS IS NOT REFLECTED ON SHEET A-2.0. PLEASE
 BE SURE SHEET A-2.0 INDICATES ALL OF THE PROPOSED
 IMPROVEMENTS. SHEE A-2.0 HAS NOT BEE REVISED TO REFLECT
 THE NEW EXTERIOR STAIRCASE
  
 2) REPEAT COMMENT: ONLY AN UNDER-THE-COUNTER
 REFRIGERATOR MAY BE INSTALLED. THIS CANNOT BE A
 SEPARATE DWELLING UNIT, CANNOT HAVE SEPARATE COOKING
 FACILITIES, AND WILL BE NOT ABLE TO BE RENTED. PLANS
 CONTINUE TO INDICATE A FULL-SIZE REFRIGERATOR, PLEASE
 ADJUST PLANS ACCORDINGLY.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 PLANNING AND ZONING DEPARTMENT
 401 CLEMATIS STREET - P.O. BOX 3366
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1435
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.CITYOFWPB.COM
  

Review Stop Z ZONING
Rev No 1 Status F Date 2010-06-02 Cont ID  
Sent By jroach Date 2010-06-02 Time 11:34 Rev Time 0.00
Received By jroach Date 2010-06-02 Time 11:34 Sent To  
Notes
2010-06-02 11:34:49ZONING PLAN REVIEW
  
 PERMIT NO.: 08070580
 ADDRESS: 203 ALPINE ROAD
 CONTRACTOR/CONTACT: JEFF CONTE
 TELEPHONE NO.: 561.324.8055
 SCOPE OF REVIEW: REVISIONS TO PROPOSED RESIDENTIAL
 ADDITION.
  
 REVIEW STATUS: FAILED
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1) SHEET A-2.3 INDICATES THE ADDITION OF AN EXTERIOR
 STAIRCASE TO THE 2ND FLOOR OF THE GARAGE???THIS IS NOT
 REFLECTED ON SHEET A-2.0. PLEASE BE SURE SHEET A-2.0
 INDICATES ALL OF THE PROPOSED IMPROVEMENTS.
  
 2) AS REQUIRED BY SECTION 94-611, ALL ROOMS OF A
 DWELLING UNIT SHALL BE ACCESSED FROM THE INTERIOR OF
 THE UNIT. THE SF7 ZONING DISTRICT ONLY PERMITS ONE (1)
 SINGLE FAMILY DWELLING UNIT. THEREFORE, THE LIVING
 SPACE ABOVE THE GARAGE CANNOT BE ACCESSED SOLELY BY AN
 EXTERIOR STAIRCASE???IT SHALL HAVE AN INTERIOR ENTRANCE
 THAT IS ACCESSED THROUGH THE REMAINDER OF THE
 RESIDENCE. ADDITIONALLY, ONLY AN UNDER-THE-COUNTER
 REFRIGERATOR MAY BE INSTALLED. THIS CANNOT BE A
 SEPARATE DWELLING UNIT, CANNOT HAVE SEPARATE COOKING
 FACILITIES, AND WILL BE NOT ABLE TO BE RENTED.
  
 3) PLEASE CLARIFY WHY THE FOUNDATION EXTENDS UNDERNEATH
 THE BAY WINDOW, WHEN IT APPEARS ON THE ELEVATION THAT
 THE BAY WINDOW WILL BE SUSPENDED ABOVE GRADE.
  
 4) DECORATIVE ELEMENTS ON TOP OF PRIVACY WALLS ARE ONLY
 PERMITTED AN ADDITIONAL 10% OF THE MAXIMUM HEIGHT
 PERMITTED BY THE ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDRS). THE DECORATIVE LIGHTING WAS NOT
 PART OF THE ORIGINAL PROPOSAL AND WAS NOT INCLUDED
 WITHIN THE VARIANCE GRANTED BY THE ZONING BOARD OF
 APPEALS (ZBA) AND SHALL BE REMOVED, OR THE WALL SHALL
 BE LOWERED TO FIT THEM WITHIN THE MAXIMUM PERMISSIBLE
 HEIGHT.
  
 5) ON THE REVISED ELEVATIONS, BUILDING HEIGHT SHALL BE
 MEASURED FROM FINISHED GRADE TO THE MEAN POINT OF
 PITCHED ROOFS, AND TO THE ROOF DECK FOR ALL FLAT ROOFS.
 DIMENSIONS SHOWN ON THE PLANS ARE NOT ACCURATELY
 MEASURED.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 PLANNING AND ZONING DEPARTMENT
 401 CLEMATIS STREET - P.O. BOX 3366
 WEST PALM BEACH, FLORIDA 33402
  