Plan Review Details - Permit 10050400
Plan Review Stops For Permit 10050400
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-06-15 Cont ID  
Sent By jwitmer Date 2010-06-15 Time 14:30 Rev Time 0.77
Received By jwitmer Date 2010-06-15 Time 14:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-05-20 Cont ID  
Sent By jwitmer Date 2010-05-20 Time 12:43 Rev Time 0.77
Received By jwitmer Date 2010-05-20 Time 12:43 Sent To  
Notes
2010-05-20 12:46:11PLANS ARE CODE COMPLIANT, WILL NEED A LICENSED
 CONTRACTOR TO SIGN ON AND LICENSURE VERIFIED.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-06-24 Cont ID  
Sent By btrobaug Date 2010-06-24 Time 14:08 Rev Time 0.00
Received By btrobaug Date 2010-06-24 Time 13:55 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-05-19 Cont ID  
Sent By btrobaug Date 2010-05-19 Time 16:39 Rev Time 0.00
Received By btrobaug Date 2010-05-19 Time 15:01 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2010-05-25 Cont ID  
Sent By mawillia Date 2010-05-25 Time 12:08 Rev Time 0.00
Received By mawillia Date 2010-05-25 Time 11:46 Sent To  
Notes
2010-05-25 12:08:24*****APPROVED*****
  
  
 PLAN SHEETS CVR, D-1.0, A-1.0, E1.01, AND E2.01 WERE
 STAMPED, INITIALED, AND DATED.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-06-15 Cont ID  
Sent By vmolina Date 2010-06-15 Time 10:00 Rev Time 0.00
Received By vmolina Date 2010-06-15 Time 10:00 Sent To  
Notes
2010-06-15 10:04:08C-2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-06-04 Cont ID  
Sent By lmartine Date 2010-06-04 Time 13:23 Rev Time 0.00
Received By lmartine Date 2010-05-18 Time 09:59 Sent To  
Notes
2010-05-18 10:01:37INCOMING SENT TO C-2

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2010-06-15 Cont ID  
Sent By jwitmer Date 2010-06-15 Time 14:30 Rev Time 0.00
Received By jwitmer Date 2010-05-20 Time 12:42 Sent To  
Notes
2010-05-20 12:43:13BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2010-06-04 Cont ID  
Sent By hmoser Date 2010-06-04 Time 09:10 Rev Time 0.00
Received By hmoser Date 2010-06-04 Time 09:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2010-06-22 Cont ID  
Sent By lwagner Date 2010-06-22 Time 11:06 Rev Time 0.00
Received By lwagner Date 2010-06-22 Time 10:55 Sent To  
Notes
2010-06-22 11:07:17PLUMBING PERMIT REQUIRED

Review Stop P PLUMBING
Rev No 1 Status F Date 2010-05-24 Cont ID  
Sent By lwagner Date 2010-05-24 Time 09:39 Rev Time 0.00
Received By lwagner Date 2010-05-20 Time 14:13 Sent To  
Notes
2010-05-20 15:07:44FBC PLUMBING 2007
 REVIEW #1
 DENIED:
  
 1. WATER CLOSETS IN ROOMS 204 B & 205 B HAVE NO VENT.
 FBC PLUMBING 901.2.1 VENTING REQUIRED.
 EVERY TRAP AND TRAPPED FIXTURE SHALL BE VENTED ...
  
 2. VENT FOR W.C. IN 204 A IS A HORIZONTAL DRY VENT.
 905.3 VENT CONNECTION TO DRAINAGE SYSTEM.
 EVERY DRY VENT CONNECTING TO A HORIZONTAL DRAIN SHALL
 CONNECT ABOVE THE CENTERLINE OF THE HORIZONTAL DRAIN
 PIPE.905.4 VERTICAL RISE OF VENT.
 EVERY DRY VENT SHALL RISE VERTICALLY TO A MINIMUM OF 6
 INCHES (152 MM) ABOVE THE FLOOD LEVEL RIM OF THE
 HIGHEST TRAP OR TRAPPED FIXTURE BEING VENTED.
  
 REVIEW BY LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 (561) 805-6692
 FAX (561) 653-2692
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 1 Status N Date 2010-05-28 Cont ID  
Sent By eschneid Date 2010-05-28 Time 15:13 Rev Time 0.15
Received By eschneid Date 2010-05-28 Time 15:13 Sent To  
Notes
2010-05-28 15:18:27INTERIOR WORK ONLY. VALUE OF PERMITS OVER LAST 12
 MONTHS LESS THAN 50% OF BUILDING.