Plan Review Details - Permit 10050326
| Plan Review Stops For Permit 10050326 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-06-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-06-03 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-06-03 |
Time |
07:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-05-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-05-18 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-05-18 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2010-05-18 14:48:44 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) SUBMIT 2 COPIES OF PRODUCT APPROVALS FOR THE | | | ACCORDION SHUTTERS AS REQUIRED BY FAC RULE 9B-72. | | | | | | 2) SUBMIT 2 COPIES OF A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE ACCORDION SHUTTERS. SPECIFY THE MOUNT, | | | FASTENER TYPE AND SPACING, SPANS, ETC. FBC R301.1 | | | | | | 3) SUBMIT 2 COPIES OF A FLOOR PLAN INDICATING THE | | | LOCATION, TYPE AND SIZE OF THE WINDOWS AND DOORS THAT | | | WILL BE REPLACED. FBC 301.1 | | | | | | 4) THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR THE | | | EXTERIOR DOOR IS EXPIRED. SUBMIT CURRENT PRODUCT | | | APPROVALS. RULE 9B-72 | | | | | | 5) PRODUCT APPROVALS WERE SUBMITTED FOR WINDOW | | | MULLIONS. PLEASE SPECIFY THE WHICH WINDOWS WILL BE | | | MULLED TOGETHER. SPECIFY THE SIZES AND CONFIGURATION. | | | FBC R301.1 | | | | | | 6) ITEM # 8 UNDER EXTERIOR ON THE SCOPE OF WORK | | | INDICATES THAT THE 2ND BATHROOM WINDOW IS TO BE | | | REPLACED AND ACCORDION SHUTTER INSTALLED. THE WINDOW | | | PRODUCT APPROVAL THAT WAS SUBMITTED IS FOR IMPACT | | | WINDOWS. PLEASE CLARIFY. | | | | | | 7) ITEM #16 UNDER MASTER BEDROOM AND ITEM #20 UNDER | | | BATHROOM SPECIFIES REPLACING WINDOWS WITHOUT ANY | | | MENTION OF IMPACT PROTECTION. ARE THESE GOING TO BE | | | IMPACT WINDOWS? IF THEY ARE NOT LISTED UNDER EXTERIOR | | | DOES THIS MEAN THEY ARE INTERIOR? PLEASE CLARIFY. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-05-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-05-14 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-05-14 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2010-05-14 08:21:51 | | | | PROVISO/REVISION REQUIRED | | | | | | R313.2.1 ALTERATIONS, REPAIRS AND ADDITIONS. WHEN | | | ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT | | | OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR | | | CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL DWELLING | | | UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS LOCATED AS | | | REQUIRED FOR NEW DWELLINGS; THE SMOKE ALARMS SHALL BE | | | INTERCONNECTED AND HARD WIRED. | | | | | | SUBMIT A FLOOR PLAN AND INDICATING THE LOCATION OF ALL | | | EQUIPMENT AND DEVICES BEING INSTALLED UNDER THE SCOPE | | | OF THIS APPLICATION.106.1.1 FBC. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-06-02 |
|
|
Cont ID |
|
| Sent By |
vmolina |
Date |
2010-06-02 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
vmolina |
Date |
2010-06-02 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2010-06-02 12:50:23 | GAVE TO RM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-05-20 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-05-20 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-05-12 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2010-05-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-05-18 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-05-18 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2010-05-18 13:45:41 | REPLACE FIXTURES IN SAME LOCATION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2010-05-20 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2010-05-20 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2010-05-20 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2010-05-20 08:51:00 | PERMIT VALUE DOES NOT EXCEED 50% OF PAPA IMPROVEMENT | | | VALUE. |
|
|
|