Plan Review Details - Permit 10040629
| Plan Review Stops For Permit 10040629 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-05-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-05-10 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-05-10 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2010-05-10 16:07:52 | ****CORRECTIONS**** (REVISED 4/29/14) | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. SHOW HOW THE PROPOSED "ACCESS DOOR" WILL RESIST WIND | | | LOADS FBC R301. **PROVIDE A DETAIL FOR THE NEW OPENING. | | | DETAIL TO INCLUDE WIND DESIGN CRITERIA FBC R 301.** | | | | | | 2. PROVIDE A SITE PLAN TO SHOW LOCATION OF ALLL | | | PROPOSED NEW DOORS, WINDOWS, AND OVERHANG. INCLUDE | | | WINDOW SIZES. | | | | | | 3. PLEASE REVISE APPLICATION TO CLARIFY ITEM #3, "ADD | | | PENT ROOF OVERHANG," NOT CLEAR WHAT A PENT ROOF IS. | | | | | | 4. FLASHING TO BE IN ACCORDANCE WITH FBC R903.1, TOP OF | | | FLASHING SHOULD NOT BE EXPOSED TO WATER WHERE THE | | | PROPOSED ROOF OVERHANG CONNECTS TO THE HOUSE. | | | | | | 5. PLANS ARE TO BE TO SCALE, FBC106. ALSO PROVIDE | | | OVERALL DIMENSIONS. **INCLUDE WIND DESIGN CRITERIA FBC | | | R 301. IF PLANS ARE NOT PREPARED BY AN ARCHITECT OR | | | ENGINEER, INCLUDE THE PRINTED NAME AND SIGNATURE OF THE | | | INDIVIDUAL TAKING RESPONSIBILITY FOR THE DESIGN FBC | | | 107.** | | | | | | 6. PROVIDE INFORMATION REGARDING THE ROOF FOR THE | | | PROPOSED OVERHANG. | | | | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-04-26 |
|
|
Cont ID |
|
| Sent By |
swurafti |
Date |
2010-04-26 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
swurafti |
Date |
2010-04-26 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2010-04-26 14:59:12 | HISTORIC APPROVED BY JPAPA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-05-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-05-10 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-04-26 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2010-04-26 15:57:06 | TO ZONING | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2010-04-27 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2010-04-27 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2010-04-27 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2010-04-27 16:11:46 | ***FAILED*** | | | | | | THE PROFILE DRAWING ON PAGE 2/3 SHOWS WHAT APPEARS TO | | | BE AN OVERHANG OF SOME SORT, HOWEVER, NONE OF THE OTHER | | | PLANS SHOW THE LOCATION OF THIS FEATURE. PLEASE PROVIDE | | | A SURVEY OF THE PROPERTY SHOWING WHERE THIS IS TO BE | | | LOCATED. | | | | | | PLEASE CONTACT KELLY FREEMAN, GIS PLANNER, AT | | | 561-822-1458 WITH QUESTIONS. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |