Plan Review Details - Permit 10040122
| Plan Review Stops For Permit 10040122 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2010-05-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-05-10 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-05-10 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2010-05-10 13:33:45 | *****PROVISO***** | | | | | | | | | THE FIRE ALARM PLAN WAS FIRE-STAMPED ACCORDINGLY; READY | | | FOR PERMIT ISSUANCE. THE FOLLOWING PROVISIONS WERE | | | ATTACHED TO PLAN SHEET FA-1.0 | | | | | | PRIOR TO THE FIRE ALARM FINAL (302), REVISED PLAN SHEET | | | FA-1.0 (REVIEWED AND STAMPED BY THIS OFFICE) REQUIRED | | | WITH THE FOLLOWING: | | | | | | 1. SHOW THE LOCATION OF THE ANN-80 KEYPAD. A SMOKE | | | DETECTOR SHALL BE OVER THIS DEVICE. | | | 2. INSTALL SMOKE DETECTOR OVER THE FIRE ALARM CONTROL | | | PANEL (F.A.C.P) . | | | 3. ADD VISUAL STROBES TO THE RESTROOMS/BATHROOMS. | | | 4. REPLACE SMOKE DETECTOR IN KITCHEN WITH HEAT | | | DETECTOR. | | | | | | BE ADVISED THAT IT MAY NECESSARY TO AMEND THE FIRE | | | ALARM LEGEND, FIRE ALARM RISER, AND FIRE ALARM SYSTEM | | | BATTERY CALCULATIONS TO REFLECT THE ABOVE REVISIONS |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2010-04-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-04-14 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-04-14 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2010-04-14 16:12:49 | *****DENIED***** | | | | | | | | | 1. SINCE THE SCOPE OF WORK IS GREATER THAN $2500.00, | | | THE APPLICANT SHALL FILE WITH THE AHJ EITHER A RECORDED | | | NOTICE OF COMMENCEMENT OR A NOTORIZED STATEMENT THAT | | | THE NOTICE OF COMMENCEMENT HAS BEEN FILED FOR | | | RECORDING, ALONG WITH A COPY THEREOF. | | | | | | 2. THE SUBMITTED PLANS HAVE THE INCORRECT ADDRESS OF | | | 1639 FORUM PLACE, SUITE 7, ZIP CODE 33416. | | | | | | 3. THE SUBMITTED PLANS ARE BETTER SUITED FOR OBTAINING | | | A BUILDING PERMIT (CHANGE OF OCCUPANCY USE) RATHER THAN | | | A FIRE ALARM PERMIT. | | | | | | 4. THE FIRE ALARM PLAN SHALL SHOW THE ADDRESSES OF EACH | | | ALARM DEVICE, FIRE ALARM RISER, FIRE ALARM NOTES, AND | | | ANY OTHER INFORMATION PERTINENT TO THE FIRE ALARM | | | INSTALLATION. | | | | | | 5. THE FIRE ALARM PLAN SHOULD BE SUBMITTED AFTER THE | | | BUILDING PERMIT (CHANGE OF OCCUPANCY USE) HAS BEEN | | | APPLIED FOR AND/OR PRINTED. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-05-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-05-04 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-05-04 |
Time |
10:33 |
Sent To |
FIRE |
|
| Notes |
| 2010-05-04 10:35:10 | SENT TO FIRE BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-04-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-04-08 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2010-04-08 |
Time |
09:43 |
Sent To |
FIRE |
|
| Notes |
|
|
|