Plan Review Details - Permit 10040100
| Plan Review Stops For Permit 10040100 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-05-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-05-03 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-05-03 |
Time |
09:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-04-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-04-19 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-04-19 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2010-04-19 11:59:28 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. THE SITE PLAN DOES NOT MATCH THE STRUCTURAL PLAN. | | | THE ENGINEER'S PLAN SHOWS A 39'1" CONCRETE SLAB WITH | | | FOOTING, SAME WIDTH AS THE HOUSE. THE SITE PLAN SHOWS | | | THE PROPOSED IMPROVEMENT EXTENDING TO THE PROPERTY | | | LINE. PLEASE RESOLVE CONFLICT. | | | | | | ADVISORY ONLY - BASED ON THE SITE PLAN, IF THE "FUTURE" | | | CBS WALL IS ON THE PROPERTY LINE, FIRE RESISTANCE WILL | | | BE REQUIRED. A COMPLETE REVIEW CANNOT BE COMPLETED | | | WITHOUT ALL INFORMATION. THIS PERMIT WILL BE ISSUED AT | | | OWNER'S RISK. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2010-05-17 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-05-17 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-05-17 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2010-05-17 17:52:49 | GAVE TO SAMANTHA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-04-22 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-04-20 |
Time |
18:36 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-04-20 |
Time |
18:36 |
Sent To |
|
|
| Notes |
| 2010-04-26 08:19:25 | TO ZONING | | | | | 2010-04-22 18:36:24 | GAVE TO SAMANTHA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-04-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-04-19 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-04-06 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2010-04-06 13:04:57 | TO ZONING./WRT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2010-04-29 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2010-04-29 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2010-04-29 |
Time |
14:22 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2010-04-16 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2010-04-16 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2010-04-16 |
Time |
12:16 |
Sent To |
B |
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |