Plan Review Details - Permit 10040026
Plan Review Stops For Permit 10040026
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-06-10 Cont ID  
Sent By shill Date 2010-06-10 Time 08:08 Rev Time 0.00
Received By shill Date 2010-06-10 Time 08:08 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-04-08 Cont ID  
Sent By shill Date 2010-04-08 Time 14:07 Rev Time 0.00
Received By shill Date 2010-04-08 Time 14:07 Sent To  
Notes
2010-04-08 14:56:52****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. ACCESSIBLE ROUTE FROM PUBLIC WAY TO ALTERED PRIMARY
 FUNCTION AREA REQUIRED, FBC11-4.1.2(1),
 FBC11-4.1.4(1)(B).
  
 2. FBC11-4.1.2(5)(A), PROVIDE: TOTAL NUMBER OF PARKING
 SPACES, TOTAL NUMBER OF ACCESSIBLE SPACES. THIS WAS
 INCLUDED ON OTHER PLANS SUBMITTED BUT PLEASE NOTE THAT
 THE PARKING LOT STRIPING IS INCLUDED IN THE SCOPE OF
 THIS PERMIT SUBMITTAL (10040026).
  
 3. A SIDEWALK RAMP IS SHOWN (C3), CURB RAMP REQUIRED,
 FBC11-4.7. THE DETAIL AS SHOWN INTRODUCES AN
 UNANTICIPATED STEP IN THE MIDDLE OF THE EGRESS PATH.
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-04-16 Cont ID  
Sent By btrobaug Date 2010-04-16 Time 11:11 Rev Time 0.00
Received By btrobaug Date 2010-04-16 Time 10:33 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2010-06-22 Cont ID  
Sent By mgonzale Date 2010-06-22 Time   Rev Time 2.00
Received By mgonzale Date 2010-06-22 Time   Sent To  
Notes
2010-06-22 13:33:31ITEMS WHERE ADDRESSED.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2010-04-29 Cont ID  
Sent By dlauderm Date 2010-04-29 Time 14:41 Rev Time 6.00
Received By dlauderm Date 2010-04-27 Time 14:40 Sent To  
Notes
2010-04-29 14:42:32ENGINEERING REVIEW FOR CONSTRUCTION SERVICES
 REVIEWER: DEAN S. LAUDERMILK, PROJECT COORDINATOR
 W-494-1083, FAX: 494-1116, EMAIL: [email protected]
 SITE PLAN NEEDS TO BE SUBMITTED TO ENGINEERING SERVICES
 DEPARTMENT (ESD) AND BE APPROVED PRIOR TO RESUBMITTAL
 TO CSD.
 THE PLAN HAS FAILED THE REVIEW FOR THE FOLLOWING
 REASONS:
 GENERAL:
 1) ALL COMMENTS NEED TO BE RESPONDED TO IN WRITING.
 2) MISSING POLLUTION CONTROL PLAN. ALL ON SITE CATCH
 BASINS NEED TO BE PROTECTED. ALL OFF-SITE CATCH BASINS
 THAT MAY BE AFFECTED BY WATER RUNNING OFFSITE NEED TO
 BE PROTECTED.
 SHEET C-1:
 1) REPAIRS ARE REQUIRED TO ALL DOWNSPOUTS. AT LEAST ONE
 IS MISSING AT THE BACK OF THE BUILDING (NORTH SIDE) AND
 IT HAS CAUSED A WASH OUT OF DIRT INTO THE STORM DRAIN
 SYSTEM. THIS IS IN VIOLATION OF THE CITY STORMWATER
 CODE. ONLY CLEAR WATER MAY ENTER THE STORM SEWER
 SYSTEM. SEE GENERAL COMMENT #2.
 2) PARKING SPACES AND ADA/HANDICAP SPACES ARE TO BE
 LISTED IN A TABLE.
 3) THE PLAN NEEDS TO SHOW IN A TABLE EXISTING AND
 PROPOSED PERVIOUS AND IMPERVIOUS AREAS.
 4) THE EXISTING CONCRETE MEDIAN IN THE ENTRANCE
 DRIVEWAY OFF OF OKEECHOBEE BLVD. IS HALF IN AND HALF
 OUT OF THE FDOT ROAD RIGHT-OF-WAY. AN FDOT PERMIT WILL
 BE REQUIRED FOR THIS WORK.
 5) THE NOTES STATE THAT THE EXISTING ASPHALT PAVEMENT
 IS TO BE REMOVED. CHANGE THESE NOTES TO STATE THE
 "EXISTING ASPHALT PAVEMENT AND BASE ARE TO BE REMOVED".
 IF THE BASE REMAINS THE AREA WILL REMAIN IMPERVIOUS.
 6) NO DRAINAGE SLOPES OR DIRECTION OF FLOW ARROWS ARE
 USED TO SHOW WHERE THE WATER WILL FLOW TO ON THE NEW
 DEAD END ROAD (TO THE SHOPPING CENTER TO THE WEST). THE
 AREA WHERE THE EXISTING DRIVEWAY IS TO BE REMOVED FLOWS
 TO THE WEST, HOW WILL THE DRAINAGE BE HANDLED?
 7) THERE IS NO DUMPSTER ENCLOSURE. CALL TO DEFINE HOW
 THE TRASH AND GARBAGE ARE TO BE PICKED UP PRIOR TO
 PUTTING NOTES AND OR AN ENCLOSURE ON THE PLAN. THERE
 WAS A COMPACTOR ON THE WEST SIDE OF THE BUILDING
 ACCORDING TO THE RECORD WE HAVE.
 SHEET C-2:
 1) VERIFY DRIVEWAY OUT OF GAS STATION PROPERTY HAS A
 STOP SIGN ON IT. THE STOP BAR IS ON THE FURNITURE STORE
 PROPERTY.
 2) THERE IS NO SIDEWALK FROM OKEECHOBEE BLVD. TO THE
 STORE FRONT, PLEASE ADD ONE. IT WILL NEED TO BE
 INSTALLED AT THE PROPER GRADES TO MEET ADA
 REQUIREMENTS.
 SHEET C-3:
 1) TYPICAL ADA/HANDICAP PARKING SPACES SHALL BE TO CITY
 DETAILS. I HAVE ATTACHED THEM FOR YOUR USE. THE FDOT
 DETAIL IS TO ONLY BE USED TO GIVE YOU THE DIMENSIONS
 REQUIRED FOR THE HANDICAP SIGN.
 2) TYPICAL PARKING SPACES SHALL BE TO CITY DETAILS. I
 HAVE ATTACHED THEM FOR YOUR USE.
 3) THERE IS "D" CURB DETAIL, BUT IT IS NOT SHOWN USED
 ON THE PLAN. PERHAPS THE DETAIL SHOULD BE REMOVED.
 4) THE WRONG FDOT DETAIL WAS USED FOR THE ADA
 REQUIREMENTS. THIS DETAIL WORKS FOR THE ADA RAMP ON THE
 EAST SIDE OF THE BUILDING, BUT NOT FOR THE FRONT OF THE
 BUILDING.
 5) WHAT IS THE CURVED STRUCTURE SHOWN IN THE WAY OF THE
 ADA RAMP ON THE SOUTH SIDE OF THE BUILDING? IF IT IS A
 ROOF LINE, EITHER REMOVE IT OR "GHOST" IT.
 SHEET C-4:
 1) ON THE WEST END OF THE PROPERTY THE IS A PRIVATE
 EASEMENT WITH A GRAVITY LATERAL GOING TO THE SANITARY
 MAIN ON THE NORTH END OF THE PROPERTY FROM THE
 GAS/CONVENIENCE STORE. THE CLEAN-OUTS ARE MISSING AND
 NEED TO BE REPLACED. THIS VIOLATES THE SANITARY CODE
 WHICH STATES THAT NO STORM WATER CAN GO INTO THE
 SANITARY SYSTEM. THE TOPS OF THE LATERALS WERE PROBABLY
 CUT OFF BY THE MOWERS. THEY NEED TO BE INSTALLED PER
 OUR DETAIL, WITH CI MINI MANHOLES IN CONCRETE, WHICH I
 HAVE ATTACHED.
 2) THE EXISTING HYDRANT TO BE RELOCATED NEEDS TO BE
 REPLACED, IT IS TOO OLD AND DOES NOT MEET THE NEW
 REQUIREMENTS.
 3) ON THE NORTH SIDE OF THE BUILDING THERE IS A
 CLEAN-OUTS MISSING AND IT NEED TO BE REPLACED. THIS
 VIOLATES THE SANITARY CODE WHICH STATES THAT NO STORM
 WATER CAN GO INTO THE SANITARY SYSTEM. THEY NEED TO BE
 INSTALLED PER OUR DETAIL, WITH CI MINI MANHOLES IN
 CONCRETE, WHICH I HAVE ATTACHED.
 4) THERE WERE DUAL REDUCED PRESSURE BACKFLOW PREVENTERS
 AT THE METER. IF THIS NOTE IS CORRECT AND THEY ARE
 MISSING THEN THE BACKFLOW PREVENTER WILL NEED TO BE
 TESTED WHEN INSTALLED BY OUR BACKFLOW PREVENTER
 TECHNICIAN (FREE OF CHARGE). ADD THE NOTE "CONTACT THE
 PUBLIC UTILITIES BACKFLOW TESTER, ED SEDA AT 822-2240
 WHEN THE BACKFLOW PREVENTER IS INSTALLED FOR TESTING
 PRIOR TO ACTIVATION".
 5) THERE IS A WELL SHOWN ON THE PROPERTY AT THE NORTH
 EAST CORNER OF THE PROPERTY. OR, IS IT A PUMP, DRAWING
 WATER OUT OF THE CANAL. IN EITHER CASE IT NEEDS TO BE
 PERMITTED THRU SFWMD. SUPPLY A COPY OF THE PERMIT OR
 THE APPLICATION, OR INSTALL A SEPARATE WATER METER FOR
 IRRIGATION. IF THE EXISTING METER IS USED ALL OF THE
 WATER USED WILL BE CHARGED AGAINST YOUR WATER AND SEWER
 BILL, AN IRRIGATION METER IS ONLY CHARGED AGAINST YOUR
 WATER BILL.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2010-06-14 Cont ID  
Sent By mawillia Date 2010-06-14 Time 15:49 Rev Time 0.00
Received By mawillia Date 2010-06-14 Time 14:51 Sent To  
Notes
2010-06-14 15:26:36*****APPROVED W/REMINDERS****
  
 PLAN SHEETS A-1.1, C-4, AND C-5 WERE STAMPED,
 INITIALED, AND DATED; THE FOLLOWING REMINDERS WAS
 ATTACHED TO A-1.1SHEET:
  
 1) FIRE DEPARTMENT ACCESS ROADS SHALL HAVE AN
 UNOBSTRUCTED WIDTH OF NOT LESS THAN 20 FEET AND AN
 UNOBSTRUCTED HEIGHT OF NOT LESS THAN 13 FEET 4 INCHES.
 THE REQUIRED WIDTH OF A FIRE DEPARTMENT ACCESS ROAD
 SHALL NOT BE OBSTRUCTED IN ANY MANNER, INCLUDING THE
 PARKING OF VEHICLES.
 2) THE FIRE DEPARTMENT SHALL BE NOTIFIED WHEN FIRE
 PROTECTION SYSTEMS ARE SHUT DOWN AND WHEN IT IS
 RETURNED TO SERVICE.
 3) THE RELOCATED HYDRANT(S) SHALL BE INSTALLED,
 COMPLETED, AND IN SERVICE PRIOR TO CONSTRUCTION AND/OR
 ALTERATION OF THE BUILDING.
  
 CAPT MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2010-04-16 Cont ID  
Sent By mawillia Date 2010-04-16 Time 15:14 Rev Time 0.00
Received By mawillia Date 2010-04-16 Time 14:42 Sent To  
Notes
2010-04-16 15:04:41*****APPROVED W/REMINDERS****
  
 PLAN SHEETS C-4 AND C-5 WERE STAMPED, INITIALED, AND
 DATED; THE FOLLOWING REMINDERS WAS ATTACHED TO C-4
 SHEET:
  
 1) THE FIRE DEPARTMENT SHALL BE NOTIFIED WHEN FIRE
 PROTECTION SYSTEMS ARE SHUT DOWN AND WHEN IT IS
 RETURNED TO SERVICE.
 2) THE RELOCATED HYDRANT(S) SHALL BE INSTALLED,
 COMPLETED, AND IN SERVICE PRIOR TO CONSTRUCTION AND/OR
 ALTERATION OF THE BUILDING.
  
 CAPT MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2010-06-25 Cont ID  
Sent By lmartine Date 2010-06-25 Time 11:45 Rev Time 0.00
Received By lmartine Date 2010-06-25 Time 11:45 Sent To  
Notes
2010-06-25 11:46:32******************EXPEDITED*****************
 3RD RUN
 IN ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-05-27 Cont ID  
Sent By lmartine Date 2010-05-27 Time 16:49 Rev Time 0.00
Received By lmartine Date 2010-05-27 Time 16:49 Sent To  
Notes
2010-05-27 16:51:31***************EXPEDITED******************
 C--10
 2ND RUN

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-05-03 Cont ID  
Sent By lmartine Date 2010-04-29 Time 09:19 Rev Time 0.00
Received By lmartine Date 2010-04-08 Time 14:56 Sent To  
Notes
2010-04-08 14:57:57*****EXPEDITED*****
  
 C4
  

Review Stop L LANDSCAPING
Rev No 3 Status N Date 2010-06-30 Cont ID  
Sent By rkussner Date 2010-06-30 Time 16:40 Rev Time 0.00
Received By rkussner Date 2010-06-30 Time 16:40 Sent To  
Notes
2010-06-30 17:01:40***LANDSCAPE REVIEW NOT REQUIRED***
  
 APPLICANT SHALL APPLY FOR A SEPARATE LANDSCAPE PERMIT
 AND SUBMIT TWO COPIES OF A SIGNED AND SEALED LANDSCAPE
 PLAN PRIOR TO CONSTRUCTION SERVICES FINAL APPROVAL.
  
 IRRIGATION WILL ALSO REQUIRE A SEPARATE PERMIT.

Review Stop L LANDSCAPING
Rev No 2 Status F Date 2010-06-04 Cont ID  
Sent By rkussner Date 2010-06-04 Time 13:47 Rev Time 0.00
Received By rkussner Date 2010-06-04 Time 13:47 Sent To  
Notes
2010-06-04 14:23:29***LANDSCAPE REVIEW FAILED***
  
 PLEASE RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT.
  
 1. REPEAT COMMENT: APPLY FOR A LANDSCAPE PERMIT. SUBMIT
 TWO COPIES OF A COMPLETE LANDSCAPE PLAN AND A CERTIFIED
 COST ESTIMATE THAT INCLUDES THE TOTAL COST OF ALL
 LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO UNIT
 COST.
  
 2. REPEAT COMMENT: PLEASE PROVIDE THE TABULATION
 NECESSARY FOR THE EVALUATION OF COMPLIANCE WITH ARTICLE
 XIV OF THE ZONING AND LAND DEVELOPMENT REGULATIONS.
  
 3. REPEAT COMMENT: PLEASE APPLY FOR A TREE ALTERATION
 PERMIT.
  
 4. REPEAT COMMENT: PURSUANT TO SECTION 94-442 (D),
 PRIVATE AND PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR
 SIDEWALK SURFACES AND REQUIRED BUFFER STRIPS AND
 LANDSCAPED OPEN SPACE AREAS SHALL BE PLANTED WITH
 GRASS. GRASS AREAS SHALL BE SODDED. THIS APPLIES TO THE
 ENTIRE SITE AND INCLUDES THE RIGHTS-OF-WAY AND
 RETENTION AREAS. THE AREA OF RIGHT-OF-WAY TO BE SODDED,
 IRRIGATED AND MAINTAINED SHALL EXTEND UP TO THE
 DRAINAGE CANAL ALONG THE EAST SIDE OF THE SITE.
  
 5. REPEAT COMMENT: ALL EXISTING TREES AND PLANT
 MATERIAL TO REMAIN SHALL BE FLORIDA #1 GRADE OR BETTER.
 ALL TREES THAT DO NOT MEET THIS REQUIREMENT SHALL
 EITHER BE REMOVED AND REPLACED OR A CERTIFIED ARBORIST
 SHALL BE HIRED TO CORRECTIVELY PRUNE THE TREES. THIS
 NOTE SHALL BE ADDED TO THE PLAN.
  
 6. REPEAT COMMENT: PURSUANT TO SECTION 94-443 (C) (3)
 (A), EACH ROW OF PARKING SPACES SHALL BE TERMINATED BY
 LANDCAPE ISLANDS OF NOT LESS THAN FIVE FEET IN WIDTH
 AND NOT LESS THAN THE LENGTH OF THE ADJACENT PARKING
 STALL. THE LANDSCAPE ISLAND SHALL CONTAIN AT LEAST ONE
 SHADE OR FLOWERING TREE. TREES ARE MISSING IN AT LEAST
 FOUR TERMINAL ISLANDS.
  
 7. REPEAT COMMENT: PLEASE INCORPORATE VERTICAL
 LANDSCAPE ELEMENTS SUCH AS SABAL OR OTHER PALMS INTO
 THE FOUNDATION PLANTING ALONG THE WEST SIDES OF THE
 BUILDING.
  
 8. CREDIT WAS TAKEN FOR THE USE OF A MOISTURE SENSING
 CONTROLLER OTHER THAN A RAIN SWITCH IN THE DESIGN
 OPTIONS. A RAIN SWITCH WAS PROPOSED. IF A MOISTURE
 SENSING CONTROLLER IS PROPOSED, PLEASE IDENTIFY IT BY
 BRAND AND MODEL NUMBER.
  
 9. PLEASE PROVIDE THE SIZE AND SPACING FOR ALL PROPOSED
 PLANT MATERIAL.
  
 10. THE SPACING OF THE REQUIRED PERIMETER TREES SHALL
 NOT EXCEED 30 FEET. THERE ARE GAPS THAT EXCEED THIRTY
 FEET ALONG THE EAST AND WEST SIDES OF THE SITE. PLEASE
 READJUST THE PLACEMENT OF THE PROPOSED TREES TO GET
 THEM AS EVENLY SPACED AS POSSIBLE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.
  

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2010-04-15 Cont ID  
Sent By rkussner Date 2010-04-15 Time 15:50 Rev Time 0.00
Received By rkussner Date 2010-04-15 Time 15:50 Sent To  
Notes
2010-04-15 17:06:00***LANDSCAPE REVIEW FAILED***
  
 PLEASE RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT.
  
 1. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF
 THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE
 (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR.
  
 2. APPLY FOR A LANDSCAPE PERMIT. SUBMIT TWO COPIES OF A
 COMPLETE LANDSCAPE PLAN AND A CERTIFIED COST ESTIMATE
 THAT INCLUDES THE TOTAL COST OF ALL LANDSCAPE MATERIALS
 AND LABOR, BROKEN DOWN INTO UNIT COST.
  
 3. PLEASE PROVIDE THE TABULATION NECESSARY FOR THE
 EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS, INCLUDING THE
 XERISCAPE DESIGN OPTIONS.
  
 4. PURSUANT TO SECTION 94-448 (D) (2), ALL OF THE ITEMS
 ENUMERATED IN THIS SECTION SHALL BE ADDRESSED ON THE
 LANDSCAPE PLAN.
  
 5. ALL UTILITIES, EASEMENTS, OVERHEAD AND UNDERGROUND
 LINES, SITE LIGHTING AND ANYTHING THAT MAY INTERFERE
 WITH THE PROPOSED LANDSCAPING SHALL BE SHOWN ON THE
 LANDSCAPE PLAN. THERE ARE CONFLICTS BETWEEN SITE
 LIGHTING AND LANDSCAPING. THE SITE LIGHTS SHALL BE KEPT
 OUT OF THE LANDCAPE ISLANDS.
  
 6. ALL LANDSCAPE ISLANDS ARE REQUIRED TO BE A MINIMUM
 OF FIVE (5) FEET IN WIDTH, EXCLUDING THE REQUIRED
 CURBING) SOME OF THE ISLANDS DO NOT APPEAR TO MEET THIS
 REQUIREMENT.
  
 7. PLEASE APPLY FOR A TREE ALTERATION PERMIT.
  
 8. PURSUANT TO SECTION 94-442 (D), PRIVATE AND PUBLIC
 RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK SURFACES AND
 REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN SPACE AREAS
 SHALL BE PLANTED WITH GRASS. GRASS AREAS SHALL BE
 SODDED. THIS APPLIES TO THE ENTIRE SITE AND INCLUDES
 THELL RIGHTS-OF-WAY AND RETENTION AREAS.
  
 9. ALL EXISTING TREES AND PLANT MATERIAL TO REMAIN
 SHALL BE FLORIDA #1 GRADE OR BETTER. ALL TREES THAT DO
 NOT MEET THIS REQUIREMENT SHALL EITHER BE REMOVED AND
 REPLACED OR A CERTIFIED ARBORIST SHALL BE HIRED TO
 CORRECTIVELY PRUNE THE TREES.
  
 10. PURSUANT TO SECTION 94-443 (C) (3) (A), EACH ROW OF
 PARKING SPACES SHALL BE TERMINATED BY LANDCAPE ISLANDS
 OF NOT LESS THAN FIVE FEET IN WIDTH AND NOT LESS THAN
 THE LENGTH OF THE ADJACENT PARKING STALL. THE LANDSCAPE
 ISLAND SHALL CONTAIN AT LEAST ONE SHADE OR FLOWERING
 TREE.
  
 11. ADDITIONAL LANDSCAPE COMMENTS MAY BE FORTHCOMING
 WHEN A MORE COMPLETE LANDSCAPE PLAN HAS BEEN SUBMITTED.
  
 12. PLEASE INCORPORATE VERTICAL LANDSCAPE ELEMENTS SUCH
 AS SABAL OR OTHER PALMS INTO THE FOUNDATION PLANTING
 ALONG THE EAST AND WEST SIDES OF THE BUILDING.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.
  
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-06-10 Cont ID  
Sent By lwagner Date 2010-06-10 Time 12:33 Rev Time 0.00
Received By lwagner Date 2010-06-10 Time 10:15 Sent To  
Notes
2010-06-10 12:33:57IRRIGATION PERMIT REQUIRED

Review Stop Z ZONING
Rev No 3 Status P Date 2010-06-30 Cont ID  
Sent By kdfreema Date 2010-06-30 Time 15:57 Rev Time 0.00
Received By kdfreema Date 2010-06-30 Time 15:57 Sent To  
Notes
2010-06-30 16:12:26***PROVISO***
  
 LANDSCAPING AND IRRIGATION REQUIRE SEPARATE PERMITS.
 REMEMBER TO ADJUST THE VALUE OF THIS PERMIT ACCORDINGLY
 ONCE THOSE TWO ITEMS ARE REMOVED FROM THE SCOPE OF
 WORK. ADDITIONALLY, MAKE SURE TO INCLUDE THE CERTIFIED
 COST ESTIMATE WITH YOUR LANDSCAPE PERMIT.
  
 PLEASE CONTACT KELLY FREEMAN, GIS PLANNER, AT
 561-822-1458 WITH ANY QUESTIONS.

Review Stop Z ZONING
Rev No 2 Status F Date 2010-06-04 Cont ID  
Sent By kdfreema Date 2010-06-04 Time 10:38 Rev Time 0.00
Received By kdfreema Date 2010-06-04 Time 10:38 Sent To  
Notes
2010-06-04 10:56:16***FAILED***
  
 1. IRRIGATION NEEDS TO BE PROVIDED TO THE SHRUBS AROUND
 THE DUMPSTER ENCLOSURE. IT DOESN???T APPEAR THAT THE
 IRRIGATION SYSTEM IN THAT AREA, AS PROPOSED, IS ABLE TO
 COVER ALL OF THE PLANT MATERIAL ADEQUATELY ENOUGH TO
 ENSURE SURVIVAL.
  
 2. CREDIT WAS TAKEN ON SHEET LA-2 FOR THE USE OF A
 MOISTURE SENSING CONTROLLER OTHER THAN A RAIN SWITCH IN
 THE DESIGN OPTIONS TABLE; HOWEVER, SHEET IR-2 SPECIFIES
 THE USE OF A RAIN BIRD MINI-CLIK RAIN SWITCH.
  
 3. IN THE DESIGN OPTIONS TABLE ON LA-2, THE SHRUB AND
 TREES SECTIONS MISTAKENLY CONTAIN A REFERENCE TO
 ???DROUGHT TOLERANT GRASS SPECIES FROM THE LIST.???
 PLEASE CHANGE ACCORDINGLY.
  
 4. SECTION 94-444(B) OF THE ZONING CODE STATES THAT THE
 SCREENING OF THE DUMPSTER ENCLOSURE MUST BE CONSTRUCTED
 OF ??????BRICK, DECORATIVE CONCRETE, OTHER DECORATIVE
 MASONRY, OF COMPARABLY DURABLE WOOD OR STEEL.??? THE
 CITY DOES NOT VIEW THE PROPOSED GATES CONSTRUCTED OF
 CHAIN LINK WITH SLATS AS MEETING THE DURABILITY
 REQUIREMENT. WE WOULD HOWEVER, ACCEPT WOOD, PVC, OR
 OPAQUE STEEL GATES AS MEETING THE DURABILITY
 REQUIREMENT.
  
 5. THE FINE FOR HANDICAP PARKING IS $252.00.
  
 6. THE LANDSCAPE PLAN DID NOT INCLUDE ANY CALCULATIONS
 TO ALLOW US TO DETERMINE COMPLIANCE WITH THE LANDSCAPE
 CODE. PLEASE SEE SECTION 94-448(D)(2) FOR THE
 REQUIREMENTS.
  
 7. PROVIDE SPACING AND SIZES ON THE PLANT LIST.
  
 8. SECTION 94-443(C)(3)(A) REQUIRES THAT EACH ROW OF
 PARKING SPACES BE TERMINATED BY A LANDSCAPE ISLAND
 CONTAINING AT LEAST ONE SHADE OF FLOWERING TREE. THERE
 ARE THREE LOCATIONS WHERE TREES ARE MISSING. THEY ARE
 IN THE ISLAND OCCUPIED BY EXISTING TREE #100, EXISTING
 TREE # 84, AND THE ISLAND IMMEDIATELY NORTH OF THE TWO
 PARALLEL HANDICAP PARKING SPACES.
  
 9. THERE ARE SEVERAL AREAS AROUND THE PERIMETER OF THE
 SITE WHERE THE SPACING BETWEEN TREES EXCEEDS THE 30
 FOOT MINIMUM SPECIFIED BY 94-443(B)(4). ADD TREES AS
 NECESSARY. IN AREAS WHICH ARE IN CLOSE PROXIMITY TO
 UNDERGROUND UTILITIES, A ROOT BARRIER SHOULD BE USED.
  
 PLEASE CONTACT KELLY FREEMAN, GIS PLANNER, AT
 561-822-1458 WITH QUESTIONS.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2010-04-13 Cont ID  
Sent By kdfreema Date 2010-04-13 Time 14:31 Rev Time 0.00
Received By kdfreema Date 2010-04-13 Time 14:31 Sent To  
Notes
2010-04-13 16:49:15***FAILED***
  
 1. PER SECTION 94-441(C)(2), THE SITE MUST NOW BE
 BROUGHT UP TO COMPLIANCE WITH THE CITY'S LANDSCAPE CODE
 BECAUSE THE VALUE OF THE WORK PROPOSED ACROSS ALL
 ACTIVE PERMITS EXCEEDS 50 PERCENT OF THE VALUE OF THE
 STRUCTURE (APPROXIMATELY 2.2 MILLION DOLLARS PER THE
 PBC PROPERTY APPRAISER).
  
 2. REVIEW ARTICLE XIV (LANDSCAPING) OF THE CITY'S
 ZONING AND LAND DEVELOPMENT REGULATIONS AND ENSURE THAT
 THE PLANS SHOW COMPLIANCE WHERE APPLICABLE.
  
 3. LANDSCAPING REQUIRES A SEPARATE PERMIT WHICH NEEDS
 TO INCLUDE A CERTIFIED COST ESTIMATE FOR MATERIALS AND
 LABOR FROM YOUR LANDSCAPE CONTRACTOR.
  
 4. HOW IS TRASH COLLECTION BEING HANDLED? THERE IS NO
 DUMPSTER ENCLOSURE SHOWN ON THE PLANS...ONE WILL BE
 REQUIRED.
  
 5. THE STRIPING DETAIL SHOWN DOES NOT MET THE CITY'S
 MINIMUM STANDARDS, PLEASE REVISE ACCORDINGLY.
  
 6. PER SECTION 94-402(B)(22), OFF-PREMISES SIGNS ARE
 PROHIBITED. THE CHEVRON SIGN AT THE NORTHEAST CORNER OF
 THE PROPERTY WILL NEED TO BE REMOVED.
  
 PLEASE CONTACT KELLY FREEMAN, GIS PLANNER, AT
 561-822-1458 WITH QUESTIONS.
  
  