Plan Review Details - Permit 10040024
Plan Review Stops For Permit 10040024
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-05-20 Cont ID  
Sent By shill Date 2010-05-20 Time 18:19 Rev Time 0.00
Received By shill Date 2010-05-20 Time 08:56 Sent To  
Notes
2010-05-20 18:24:45PROVISO -
  
 ISSUED AT CONTRACTOR'S RISK. ACCESSIBLE ROUTE FROM
 PUBLIC WAY IS TO BE SHOWN ON 10040026, SITEWORK PERMIT.
 ACCESSIBLE ROUTE IS SHOWN IN THIS PERMIT AS
 INFORMATIONAL BUT IS NOT INCLUDED IN SCOPE OF WORK AS
 THIS IS AN INTERIOR RENOVATION PERMIT ONLY. THE SITE
 PLAN IS TO BE REVIEWED/APPROVED BY ZONING AND
 ENGINEERING AS A PART OF 10040026.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-04-07 Cont ID  
Sent By shill Date 2010-04-07 Time 10:41 Rev Time 0.00
Received By shill Date 2010-04-06 Time 15:10 Sent To  
Notes
2010-04-07 10:42:11****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. FBC11 4.1.2(1), ACCESSIBLE ROUTE FROM THE PUBLIC WAY
 REQUIRED. SEE ALSO FBC11 4.1.6(B).
  
 2. FBC EB 401.4, A DESIGN PROFESSIONAL MUST ELECT ONE
 OR A COMBINATION OF LEVELS OF ALTERATION.
  
 3. DOOR 14 IS TO MEET REQUIREMENTS OF FBC11 4.13.6, SEE
 ALSO FIGURE 11 25, MANEUVERING CLEARANCE, PULL SIDE
 (18IN REQUIRED).
  
 4. FBC801.2.2, SHOW COMPLIANCE FOR THE FOAM GAZEBO.
 SHOP DRAWINGS WILL ALSO BE REQUIRED AT INSPECTION.
  
 5. FBC11 4.15.5 AND FBC 11 FIG 27(A), SEE DETAIL 10
 A5.1, 3.5IN SHOWN FOR DRINKING FOUNTAIN EDGE, 8IN MIN
 REQUIRED. IT APPEARS THAT THE SAME DETAIL SERVES FOR
 BOTH THE ACCESSIBLE AND NON ACCESSIBLE DRINKING
 FOUNTAIN, BUT NOT ALL DIMENSIONS WERE INCLUDED. PLEASE
 SEE HEIGHT ON DETAIL 10 A5.1, WHICH IS SHOWN AT TOP OF
 FOUNTAIN BUT FIG 27(A) SHOWS DETAIL TO TOP OF SPOUT
 FBC11 4.15.2.
  
 6. FBC11 4.1.3(10)(B), AT LEAST 50 PERCENT OF DRINKING
 FOUNTAINS PROVIDED SHALL COMPLY WITH FBC11 4.15. ONLY
 ONE OF THREE IS SHOWN
  
 7. FBC 11 FIG 30(E), SPECIFY GRAB BAR LENGTH. PLEASE
 NOTE THAT GRAPHICALLY THE SIDE GRAB BARS ARE SHOWN AS
 SHORTER THAN THE REAR GRAB BAR ON THE ENLARGED PLAN
 DETAIL 1 A5.1 (BUT GRAPHICALLY SHOWN CORRECTLY ON
 ELEVATIONS).
  
 8. M7.1 STATES THAT MOUNTING OF ROOFTOP EQUIPMENT WILL
 BE PERFORMED BY A STRUCTURAL ENGINEER. THIS WILL BE
 REQUIRED PRIOR TO INSTALLATION. IF THE EQUIPMENT IS
 NEW, STRUCTURAL ENGINEER IS TO ADDRESS ADDITIONAL LOADS
 ON THE ROOF STRUCTURE. (PROVISO ITEM, PRIOR TO
 INSTALLATION.)
  
 9. INFORMATIONAL ONLY, SEPARATE PERMITS REQUIRED FOR
 STOREFRONT, EXTERIOR DOORS, OVERHEAD DOORS.
  
 IF ALL OTHER TRADES PASS REVIEW, A PASSED WITH PROVISO
 (REVISION REQUIRED) STATUS CAN BE CONSIDERED.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-04-15 Cont ID  
Sent By btrobaug Date 2010-04-15 Time 08:59 Rev Time 0.00
Received By btrobaug Date 2010-04-15 Time 07:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2010-05-24 Cont ID  
Sent By mawillia Date 2010-05-24 Time 15:21 Rev Time 0.00
Received By mawillia Date 2010-05-24 Time 14:40 Sent To  
Notes
2010-05-24 15:07:13*****APPROVED*****
  
 THE COMMENTS FROM THE PREVIOUS REVIEW HAVE BEEN
 ADDRESSED; PLAN SHEETS A-1.1, A-2.1, A-5.3, A-5.5,
 E2.1A, E2.1B, FA0.1, FA2.1A, FA2.1B, FA5.1, AND
 SP-1(WITH RED-LINED PROJECT ADDRESS) WERE STAMPED,
 INITIALED, AND DATED.
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2010-04-19 Cont ID  
Sent By mawillia Date 2010-04-19 Time 11:55 Rev Time 0.00
Received By mawillia Date 2010-04-18 Time 13:57 Sent To  
Notes
2010-04-19 11:34:21*****UNSAT*****
  
  
 1. HOW WILL FIRE SRINKLER PROTECTION UNDERNEATH THE
 GAZEBO BE ACCOMPLISHED?
  
 2. THE DOOR SCHEDULE, ON SHEET A-5.5, DOES NOT INDICATE
 WHICH DOORS ARE FIRE DOORS AND THE DURATION OF THE
 RATING.
  
 3. AMEND FIRE ALARM NOTE #17, ON SHEET FA0.1, TO
 REFLECT AS PER LOCAL CODE: DUCT SMOKE DETECTORS SHALL
 INITIATE A GENERAL FIRE ALARM.
  
 4. ON SHEET SP-1, THE PROJECT SITE ADDRESS SHALL BE
 INCLUDED IN THE TTLE BLOCK.
  
  
 THE APPROPIATE PLAN SHEETS TO BE FIRE-STAMPED WHEN THE
 ABOVE COMMENTS AS WELL AS THOSE OF THE OTHER PLAN
 EXAMINERS HAVE BEEN ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2010-07-23 Cont ID  
Sent By lmartine Date 2010-07-23 Time 13:54 Rev Time 0.00
Received By lmartine Date 2010-07-23 Time 13:54 Sent To  
Notes
2010-07-23 13:56:21ROUTED INCORRECTLY, SEE REVISION #10070608, LM
2010-07-23 13:54:59IN ELECTRIC BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-05-13 Cont ID  
Sent By lmartine Date 2010-05-11 Time 17:06 Rev Time 0.00
Received By lmartine Date 2010-05-11 Time 17:06 Sent To  
Notes
2010-05-13 17:08:10*****************EXPEDITED ****************
 2ND RUN
 C--17

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-04-21 Cont ID  
Sent By shill Date 2010-04-21 Time 15:50 Rev Time 0.00
Received By shill Date 2010-04-01 Time 14:20 Sent To  
Notes
2010-04-04 14:27:48**************EXPEDITED****************
 C--3

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2010-05-25 Cont ID  
Sent By shill Date 2010-05-25 Time 13:33 Rev Time 0.00
Received By shill Date 2010-05-25 Time 13:33 Sent To  
Notes
2010-05-25 13:33:42NO IMPACT FEES DUE, PLANS STAMPED
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2010-05-20 Cont ID  
Sent By shill Date 2010-05-20 Time 18:19 Rev Time 0.00
Received By shill Date 2010-05-20 Time 18:19 Sent To  
Notes
2010-05-20 18:21:14IMPACT FEE ASSESSMENT REQUIRED ON EITHER 10040024 OR
 10040028.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2010-04-21 Cont ID  
Sent By shill Date 2010-04-21 Time 15:50 Rev Time 0.00
Received By shill Date 2010-04-21 Time 15:50 Sent To  
Notes
2010-04-21 15:50:26INTERIOR RENOVATION
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2010-05-21 Cont ID  
Sent By hmoser Date 2010-05-21 Time 08:45 Rev Time 0.00
Received By hmoser Date 2010-05-21 Time 08:45 Sent To  
Notes
2010-05-21 08:52:35PROVISO
 PLEASE REFER TO SECTION 301.12 WIND RESISTANCE . PLEASE
 PROVIDE A LETTER FROM THE ENGINEER ON THE WIND OF 140
 MPH AND WIND PRESSURE ,FOR THE EQUIPMENT .
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2010-04-16 Cont ID  
Sent By hmoser Date 2010-04-16 Time 11:16 Rev Time 0.00
Received By hmoser Date 2010-04-16 Time 11:16 Sent To  
Notes
2010-04-16 11:49:53PLAN DENIED
 1) PLEAS PROVIDE A DETAIL ON THE PLANS HOW THE RTU
 CURBS , CONDENSER STAND AND FAN CURBS ARE ANCHORED TO
 THE ROOF .
 2) PLEASE REFER TO SECTION 301.12 FBC (M) WIND
 RESISTANCE .
 3) PLEASE REFER TO SECTION 606.2.1 SUPPLY AIR SYSTEM
 AND SECTION 606.4.1 SUPERVISION . FOR AIR HANDLER # 1
 ,OR A SIELD LETTER FROM THE MANUFACTURER'S ENGINEER
 STATING NO WAY SHAPE OR FORM WILL THE AIR HANDLER
 PRODUCE MORE THAN 2000 CFM .
 4) THE OCCUPANT LODE ON THE FRESH AIR CALCULATIONS PAGE
 M-01 AND OCCUPANT LODE ON LIFE SAFETY PLAN PAGE A-21 DO
 NOT MATCH .PLEASE EXPLAIN.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-04-12 Cont ID  
Sent By lwagner Date 2010-04-12 Time 11:38 Rev Time 0.00
Received By lwagner Date 2010-04-06 Time 06:38 Sent To  
Notes
2010-04-12 11:40:50TWO OF THE THREE DRINKING FOUNTAIN TO BE HC - 11-4.1.3
 (10)

Review Stop Z ZONING
Rev No 1 Status N Date 2010-04-13 Cont ID  
Sent By kdfreema Date 2010-04-13 Time 09:55 Rev Time 0.00
Received By kdfreema Date 2010-04-13 Time 09:55 Sent To  
Notes
2010-04-13 10:03:51INTERIOR WORK ONLY