| Plan Review Stops For Permit 10040024 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-05-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-05-20 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-05-20 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2010-05-20 18:24:45 | PROVISO - | | | | | | ISSUED AT CONTRACTOR'S RISK. ACCESSIBLE ROUTE FROM | | | PUBLIC WAY IS TO BE SHOWN ON 10040026, SITEWORK PERMIT. | | | ACCESSIBLE ROUTE IS SHOWN IN THIS PERMIT AS | | | INFORMATIONAL BUT IS NOT INCLUDED IN SCOPE OF WORK AS | | | THIS IS AN INTERIOR RENOVATION PERMIT ONLY. THE SITE | | | PLAN IS TO BE REVIEWED/APPROVED BY ZONING AND | | | ENGINEERING AS A PART OF 10040026. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-04-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-04-07 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-04-06 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2010-04-07 10:42:11 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. FBC11 4.1.2(1), ACCESSIBLE ROUTE FROM THE PUBLIC WAY | | | REQUIRED. SEE ALSO FBC11 4.1.6(B). | | | | | | 2. FBC EB 401.4, A DESIGN PROFESSIONAL MUST ELECT ONE | | | OR A COMBINATION OF LEVELS OF ALTERATION. | | | | | | 3. DOOR 14 IS TO MEET REQUIREMENTS OF FBC11 4.13.6, SEE | | | ALSO FIGURE 11 25, MANEUVERING CLEARANCE, PULL SIDE | | | (18IN REQUIRED). | | | | | | 4. FBC801.2.2, SHOW COMPLIANCE FOR THE FOAM GAZEBO. | | | SHOP DRAWINGS WILL ALSO BE REQUIRED AT INSPECTION. | | | | | | 5. FBC11 4.15.5 AND FBC 11 FIG 27(A), SEE DETAIL 10 | | | A5.1, 3.5IN SHOWN FOR DRINKING FOUNTAIN EDGE, 8IN MIN | | | REQUIRED. IT APPEARS THAT THE SAME DETAIL SERVES FOR | | | BOTH THE ACCESSIBLE AND NON ACCESSIBLE DRINKING | | | FOUNTAIN, BUT NOT ALL DIMENSIONS WERE INCLUDED. PLEASE | | | SEE HEIGHT ON DETAIL 10 A5.1, WHICH IS SHOWN AT TOP OF | | | FOUNTAIN BUT FIG 27(A) SHOWS DETAIL TO TOP OF SPOUT | | | FBC11 4.15.2. | | | | | | 6. FBC11 4.1.3(10)(B), AT LEAST 50 PERCENT OF DRINKING | | | FOUNTAINS PROVIDED SHALL COMPLY WITH FBC11 4.15. ONLY | | | ONE OF THREE IS SHOWN | | | | | | 7. FBC 11 FIG 30(E), SPECIFY GRAB BAR LENGTH. PLEASE | | | NOTE THAT GRAPHICALLY THE SIDE GRAB BARS ARE SHOWN AS | | | SHORTER THAN THE REAR GRAB BAR ON THE ENLARGED PLAN | | | DETAIL 1 A5.1 (BUT GRAPHICALLY SHOWN CORRECTLY ON | | | ELEVATIONS). | | | | | | 8. M7.1 STATES THAT MOUNTING OF ROOFTOP EQUIPMENT WILL | | | BE PERFORMED BY A STRUCTURAL ENGINEER. THIS WILL BE | | | REQUIRED PRIOR TO INSTALLATION. IF THE EQUIPMENT IS | | | NEW, STRUCTURAL ENGINEER IS TO ADDRESS ADDITIONAL LOADS | | | ON THE ROOF STRUCTURE. (PROVISO ITEM, PRIOR TO | | | INSTALLATION.) | | | | | | 9. INFORMATIONAL ONLY, SEPARATE PERMITS REQUIRED FOR | | | STOREFRONT, EXTERIOR DOORS, OVERHEAD DOORS. | | | | | | IF ALL OTHER TRADES PASS REVIEW, A PASSED WITH PROVISO | | | (REVISION REQUIRED) STATUS CAN BE CONSIDERED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-04-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-04-15 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-04-15 |
Time |
07:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2010-05-24 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-05-24 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-05-24 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2010-05-24 15:07:13 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS REVIEW HAVE BEEN | | | ADDRESSED; PLAN SHEETS A-1.1, A-2.1, A-5.3, A-5.5, | | | E2.1A, E2.1B, FA0.1, FA2.1A, FA2.1B, FA5.1, AND | | | SP-1(WITH RED-LINED PROJECT ADDRESS) WERE STAMPED, | | | INITIALED, AND DATED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2010-04-19 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-04-19 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-04-18 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2010-04-19 11:34:21 | *****UNSAT***** | | | | | | | | | 1. HOW WILL FIRE SRINKLER PROTECTION UNDERNEATH THE | | | GAZEBO BE ACCOMPLISHED? | | | | | | 2. THE DOOR SCHEDULE, ON SHEET A-5.5, DOES NOT INDICATE | | | WHICH DOORS ARE FIRE DOORS AND THE DURATION OF THE | | | RATING. | | | | | | 3. AMEND FIRE ALARM NOTE #17, ON SHEET FA0.1, TO | | | REFLECT AS PER LOCAL CODE: DUCT SMOKE DETECTORS SHALL | | | INITIATE A GENERAL FIRE ALARM. | | | | | | 4. ON SHEET SP-1, THE PROJECT SITE ADDRESS SHALL BE | | | INCLUDED IN THE TTLE BLOCK. | | | | | | | | | THE APPROPIATE PLAN SHEETS TO BE FIRE-STAMPED WHEN THE | | | ABOVE COMMENTS AS WELL AS THOSE OF THE OTHER PLAN | | | EXAMINERS HAVE BEEN ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2010-07-23 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-07-23 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-07-23 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2010-07-23 13:56:21 | ROUTED INCORRECTLY, SEE REVISION #10070608, LM | | 2010-07-23 13:54:59 | IN ELECTRIC BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-05-13 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-05-11 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-05-11 |
Time |
17:06 |
Sent To |
|
|
| Notes |
| 2010-05-13 17:08:10 | *****************EXPEDITED **************** | | | 2ND RUN | | | C--17 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-04-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-04-21 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-04-01 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2010-04-04 14:27:48 | **************EXPEDITED**************** | | | C--3 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2010-05-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-05-25 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-05-25 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2010-05-25 13:33:42 | NO IMPACT FEES DUE, PLANS STAMPED | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2010-05-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-05-20 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-05-20 |
Time |
18:19 |
Sent To |
|
|
| Notes |
| 2010-05-20 18:21:14 | IMPACT FEE ASSESSMENT REQUIRED ON EITHER 10040024 OR | | | 10040028. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2010-04-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-04-21 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-04-21 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2010-04-21 15:50:26 | INTERIOR RENOVATION | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2010-05-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-05-21 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-05-21 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2010-05-21 08:52:35 | PROVISO | | | PLEASE REFER TO SECTION 301.12 WIND RESISTANCE . PLEASE | | | PROVIDE A LETTER FROM THE ENGINEER ON THE WIND OF 140 | | | MPH AND WIND PRESSURE ,FOR THE EQUIPMENT . | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2010-04-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-04-16 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-04-16 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2010-04-16 11:49:53 | PLAN DENIED | | | 1) PLEAS PROVIDE A DETAIL ON THE PLANS HOW THE RTU | | | CURBS , CONDENSER STAND AND FAN CURBS ARE ANCHORED TO | | | THE ROOF . | | | 2) PLEASE REFER TO SECTION 301.12 FBC (M) WIND | | | RESISTANCE . | | | 3) PLEASE REFER TO SECTION 606.2.1 SUPPLY AIR SYSTEM | | | AND SECTION 606.4.1 SUPERVISION . FOR AIR HANDLER # 1 | | | ,OR A SIELD LETTER FROM THE MANUFACTURER'S ENGINEER | | | STATING NO WAY SHAPE OR FORM WILL THE AIR HANDLER | | | PRODUCE MORE THAN 2000 CFM . | | | 4) THE OCCUPANT LODE ON THE FRESH AIR CALCULATIONS PAGE | | | M-01 AND OCCUPANT LODE ON LIFE SAFETY PLAN PAGE A-21 DO | | | NOT MATCH .PLEASE EXPLAIN. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2010-04-12 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-04-12 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-04-06 |
Time |
06:38 |
Sent To |
|
|
| Notes |
| 2010-04-12 11:40:50 | TWO OF THE THREE DRINKING FOUNTAIN TO BE HC - 11-4.1.3 | | | (10) |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2010-04-13 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2010-04-13 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2010-04-13 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2010-04-13 10:03:51 | INTERIOR WORK ONLY |
|
|