Plan Review Details - Permit 10030809
Plan Review Stops For Permit 10030809
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-04-06 Cont ID  
Sent By rmcdouga Date 2010-04-06 Time 15:04 Rev Time 0.00
Received By rmcdouga Date 2010-04-06 Time 15:04 Sent To  
Notes
2010-04-06 16:14:312007 FBC W/2009 REVISIONS
 ADDITION
  
 DENIED BY BUILDING
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) THE VALUE OF $10,000 SPECIFIED ON THE APPLICATION IS
 TOO LOW. THE VALUE HAS BEEN CHANGED TO $29,385, WHICH
 IS THE CALCULATED VALUE USING THE LATEST ICC BUILDING
 VALUATION DATA PER CITY ORDINANCE. ADDITIONAL PERMIT
 FEES ARE DUE.
  
 3) SUBMIT 2 COPIES OF ENERGY CALCULATIONS FOR THE
 ADDITION AS REQUIRED BY FBC 13-101.2.2 AND 13-600.
  
 4) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE
 EXTERIOR DOORS, WINDOWS, ROOF SHINGLES, HURRICANE
 STRAPS, HANGERS, CONNECTORS, STORM PANELS, ETC. AS
 REQUIRED BY DCA RULE 9B-72.
  
 5) SPECIFY THE WINDOW TYPE AND SIZES ON THE PLANS.
  
 6) SHOW COMPLIANCE WITH FBC R320 FOR TERMITE
 PROTECTION.
  
 7) FBC R313.2.1 REQUIRES THE DWELLING UNIT TO BE
 EQUIPPED WITH SMOKE ALARMS AS REQUIRED FOR NEW
 DWELLINGS. SHOW COMPLIANCE.
  
 8) FBC 313.4 REQUIRES CARBON MONOXIDE ALARMS WITHIN 10
 FEET OF EACH ROOM USED FOR SLEEPING PURPOSES. SHOW
 COMPLIANCE.
  
 9) SPECIFY THE MATERIAL THAT WILL BE INSTALLED ON THE
 SOFFITS ON THE PLANS.
  
 10) SHOW COMPLIANCE WITH FBC R803.2.3.1 WHICH REQUIRES
 THE ROOF SHEATHING TO BE FASTENED WITH 8D RING SHANK
 NAILS.
  
 11) SHOW COMPLIANCE WITH FBC R806 FOR REQUIRED ROOF
 VENTILATION.
  
 12) SHOW COMPLIANCE WITH FBC R703.6.3 FOR THE REQUIRED
 BOND BREAK BETWEEN THE STUCCO AND THE WATER-RESISTIVE
 BARRIER.
  
 13) SHOW COMPLIANCE WITH FBC R703.6.2 AND ASTM C 1063
 FOR THE REQUIRED FOUNDATION WEEP SCREED AT THE BOTTOM
 OF THE FRAMED EXTERIOR WALLS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-04-12 Cont ID  
Sent By btrobaug Date 2010-04-12 Time 14:35 Rev Time 0.00
Received By btrobaug Date 2010-04-12 Time 14:25 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-04-12 Cont ID  
Sent By btrobaug Date 2010-04-12 Time 14:36 Rev Time 0.00
Received By btrobaug Date 2010-04-06 Time 15:04 Sent To  
Notes
2010-04-12 14:36:39SMALL PLAN HOLDING BIN UNDER "E"./WRT.
2010-04-01 08:27:19INCOMING SENT TO R-4

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2010-04-06 Cont ID  
Sent By rmcdouga Date 2010-04-06 Time 15:01 Rev Time 0.00
Received By rmcdouga Date 2010-04-06 Time 15:01 Sent To  
Notes
2010-04-06 15:04:04COUNTY IMPACT FEE REVIEW IS REQUIRED BEFORE PERMIT IS
 ISSUED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2010-04-06 Cont ID  
Sent By rmcdouga Date 2010-04-06 Time 16:24 Rev Time 0.00
Received By rmcdouga Date 2010-04-06 Time 16:24 Sent To  
Notes
2010-04-06 16:31:27NO MECHANICAL PLANS WERE SUBMITTED.

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-04-06 Cont ID  
Sent By rmcdouga Date 2010-04-06 Time 15:01 Rev Time 0.00
Received By rmcdouga Date 2010-04-06 Time 15:01 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2010-04-08 Cont ID  
Sent By eschneid Date 2010-04-08 Time 16:19 Rev Time 0.50
Received By eschneid Date 2010-04-08 Time 16:19 Sent To  
Notes
2010-04-08 16:19:37FAILED
  
 1) THE SITE PLAN PROVIDED DOES NOT MATCH THE 2009
 AERIAL. A CURRENT SURVEY, LESS THEN A YEAR OLD, SHOWING
 ALL SITE IMPROVEMENTS IS REQUIRED.
  
 2) THE SITE PLAN SHOWING THE ADDITION SHALL BE TO SCALE
 AND SHOW THE SETBACK DIMENSION FROM THE CLOSEST
 PROJECTION OF THE HOUSE TO THE PROPERTY LINE. THIS WILL
 BE FOR THE NORTHWEST CORNER OF THE EXISTING HOUSE AND
 THE SOUTHWEST CORNER OF THE PROPOSED ADDITION. PLEASE
 NOTE THAT THERE SHALL BE A TOTAL OF 15 FEET OF SIDE
 SETBACK WITH A MINIMUM OF 5 FEET TO THE CLOSEST SIDE.
  
 3) NOTE: THE OVERHANG DIMENSION FOR ZONING PURPOSES IS
 TO THE FURTHEST PROJECTION OF THE OVERHANG. THE ACTUAL
 OVERHANG SCALES AT 2 FEET 4 INCHES.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.