Plan Review Details - Permit 10030740
Plan Review Stops For Permit 10030740
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-06-17 Cont ID  
Sent By rmcdouga Date 2010-06-17 Time 12:29 Rev Time 0.00
Received By rmcdouga Date 2010-06-17 Time 11:32 Sent To  
Notes
2010-06-17 13:30:33SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR STORM
 PANELS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-04-13 Cont ID  
Sent By rmcdouga Date 2010-04-13 Time 16:47 Rev Time 0.00
Received By rmcdouga Date 2010-04-13 Time 16:47 Sent To  
Notes
2010-04-13 15:06:462007 FBC W/2009 REVISIONS
 ENCLOSE CARPORT FOR STORAGE
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR EXTERIOR
 DOOR AND WINDOW AS REQUIRED BY DCA RULE 9B-72.
  
 2) SPECIFY THE WIND DESIGN DATA ( WINDSPEED, EXPOSURE
 CATEGORY,ETC.) AND OPENING PRESSURES ON THE PLANS. FBC
 R301 ( 140 MPH WINDSPEED, EXPOSURE 'C' )
  
 3) SPECIFY THE WATER-RESISTIVE BARRIER REQUIRED BY FBC
 R 703.2.
  
 4) SPECIFY THE BOND BREAK REQUIRED BY FBC R703.6.3
 BETWEEN THE STUCCO AND THE WATER-RESISTIVE BARRIER.
  
 5) FBC 703.6.2 AND ASTM C 1063 REQUIRE A FOUNDATION
 WEEP SCREED TO BE INSTALLED AT THE BOTTOM OF ALL FRAMED
 EXTERIOR WALLS, BELOW THE FLOOR LINE, WHERE THE WALL IS
 SUPPORTED BY A FLOOR OR FOUNDATION.
  
 6) SHOW COMPLIANCE WITH FBC R704 WHICH REQUIRES A 6
 INCH CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND
 FINAL EARTH GRADE.
  
 7) WALL SWITCHED LIGHTING OUTLETS ARE REQUIRED IN THE
 STORAGE ROOM AND AT THE EXTERIOR DOOR IN ACCORDANCE
 WITH THE 2008 NEC ARTICLE 210.70.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-06-02 Cont ID  
Sent By vmolina Date 2010-06-02 Time 12:34 Rev Time 0.00
Received By vmolina Date 2010-05-24 Time 08:27 Sent To  
Notes
2010-06-02 12:34:35IN ZONING BOX
2010-05-24 08:31:03SENT TO R15

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-04-13 Cont ID  
Sent By rmcdouga Date 2010-04-13 Time 16:47 Rev Time 0.00
Received By rmcdouga Date 2010-03-30 Time 10:05 Sent To  
Notes
2010-03-31 10:05:50SENT TO ZONING BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2010-06-13 Cont ID  
Sent By astelly Date 2010-06-13 Time 13:19 Rev Time 0.00
Received By astelly Date 2010-06-13 Time 13:19 Sent To  
Notes
2010-06-13 13:44:58AMY STELLLY
 PLANNING AND ZONING
 822-1442
  
 PASSED W/PROVISO
  
 LOCATION OF PROPOSED WORK MAY NOT EXTEND BEYOND
 EXISTING BUILDING LINES.

Review Stop Z ZONING
Rev No 1 Status F Date 2010-04-06 Cont ID  
Sent By astelly Date 2010-04-06 Time 10:14 Rev Time 0.00
Received By astelly Date 2010-04-06 Time 10:14 Sent To  
Notes
2010-04-06 10:21:16AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 PLEASE SUBMIT A SITE PLAN WHICH CLEARLY SHOWS THE
 LOCATION OF THE PROJECT. THE SETBACKS FOR SF7 ZONING
 DISTRICTS ARE AS FOLLOWS:
  
 MINIMUM SETBACKS FOR PRINCIPAL BUILDING.
 A.
 FRONT: 25 FEET;
 B.
 CORNER: 12.5 FEET;
 C.
 REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER IS
 LESS;
 D.
 SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL.
  
 MAXIMUM BUILDING HEIGHT: 30 FEET.
  
  