Plan Review Details - Permit 10030740
| Plan Review Stops For Permit 10030740 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-06-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-06-17 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-06-17 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2010-06-17 13:30:33 | SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR STORM | | | PANELS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-04-13 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-04-13 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2010-04-13 15:06:46 | 2007 FBC W/2009 REVISIONS | | | ENCLOSE CARPORT FOR STORAGE | | | | | | DENIED BY BUILDING | | | | | | 1) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR EXTERIOR | | | DOOR AND WINDOW AS REQUIRED BY DCA RULE 9B-72. | | | | | | 2) SPECIFY THE WIND DESIGN DATA ( WINDSPEED, EXPOSURE | | | CATEGORY,ETC.) AND OPENING PRESSURES ON THE PLANS. FBC | | | R301 ( 140 MPH WINDSPEED, EXPOSURE 'C' ) | | | | | | 3) SPECIFY THE WATER-RESISTIVE BARRIER REQUIRED BY FBC | | | R 703.2. | | | | | | 4) SPECIFY THE BOND BREAK REQUIRED BY FBC R703.6.3 | | | BETWEEN THE STUCCO AND THE WATER-RESISTIVE BARRIER. | | | | | | 5) FBC 703.6.2 AND ASTM C 1063 REQUIRE A FOUNDATION | | | WEEP SCREED TO BE INSTALLED AT THE BOTTOM OF ALL FRAMED | | | EXTERIOR WALLS, BELOW THE FLOOR LINE, WHERE THE WALL IS | | | SUPPORTED BY A FLOOR OR FOUNDATION. | | | | | | 6) SHOW COMPLIANCE WITH FBC R704 WHICH REQUIRES A 6 | | | INCH CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND | | | FINAL EARTH GRADE. | | | | | | 7) WALL SWITCHED LIGHTING OUTLETS ARE REQUIRED IN THE | | | STORAGE ROOM AND AT THE EXTERIOR DOOR IN ACCORDANCE | | | WITH THE 2008 NEC ARTICLE 210.70. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-06-02 |
|
|
Cont ID |
|
| Sent By |
vmolina |
Date |
2010-06-02 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
vmolina |
Date |
2010-05-24 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2010-06-02 12:34:35 | IN ZONING BOX | | 2010-05-24 08:31:03 | SENT TO R15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-04-13 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-03-30 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2010-03-31 10:05:50 | SENT TO ZONING BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2010-06-13 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2010-06-13 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2010-06-13 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2010-06-13 13:44:58 | AMY STELLLY | | | PLANNING AND ZONING | | | 822-1442 | | | | | | PASSED W/PROVISO | | | | | | LOCATION OF PROPOSED WORK MAY NOT EXTEND BEYOND | | | EXISTING BUILDING LINES. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2010-04-06 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2010-04-06 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2010-04-06 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2010-04-06 10:21:16 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | PLEASE SUBMIT A SITE PLAN WHICH CLEARLY SHOWS THE | | | LOCATION OF THE PROJECT. THE SETBACKS FOR SF7 ZONING | | | DISTRICTS ARE AS FOLLOWS: | | | | | | MINIMUM SETBACKS FOR PRINCIPAL BUILDING. | | | A. | | | FRONT: 25 FEET; | | | B. | | | CORNER: 12.5 FEET; | | | C. | | | REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER IS | | | LESS; | | | D. | | | SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | | | MAXIMUM BUILDING HEIGHT: 30 FEET. | | | | | | |
|
|
|