Plan Review Details - Permit 10030553
| Plan Review Stops For Permit 10030553 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-04-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-04-14 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-04-14 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2010-04-14 14:17:28 | ISSUED AT CONTRACTOR'S RISK | | | | | | PROVISO : RESPONSE FROM ARCHITECT VIA EMAIL, INSPECTOR | | | TO CONFIRM IN FIELD: | | | | | | | | | REGARDING THE APPLICATION FOR A RAMP AT THE EXISTING | | | SIDE ENTRANCE TO TEMPLE BETH EL (PERMIT NO. 10030553, I | | | HAVE THE FOLLOWING COMMENT: | | | | | | THE DOOR WIDTH ADJACENT TO THE PROPOSED RAMP IS 3'-6". | | | 2 ADDITIONAL DOORS(A MAIN ENTRY/EGRESS FOR THE SAME | | | AREA) WHICH ARE 4' WIDE EACH(A TOTAL EGRESS WIDTH OF | | | 8') ARE LOCATED 12' AWAY. | | | | | | THE PROPOSED RAMP IS 5' WIDE, WHICH DOES NOT MAKE THE | | | EXIT NARROWER. | | | | | | BOTH THESE EXITS SERVE ONLY A SMALL AREA CONSISTING OF | | | 3 SMALL OFFICES, AND TWO REST ROOMS, AS WELL A | | | CONFERENCE ROOM. | | | | | | THE ASSEMBLY HALL NEXT TO THIS AREA HAS ITS OWN DIRECT | | | EXIST, INCLUDING 3-6' WIDE DOORS WITH PANIC HARDWARE | | | AND WOULD NOT BE COUNTED IN THE SECONDARY OFFICE EXIT | | | AT WHICH THE PROPOSED RAMP IS TO BE INSTALLED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-04-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-04-06 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-04-06 |
Time |
14:39 |
Sent To |
Z |
|
| Notes |
| 2010-04-06 14:40:59 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. SEE FBC1005.2 AND REVISE PLAN TO SHOW COMPLIANCE | | | (CANNOT REDUCE EGRESS WIDTH TO LESS THAN HALF). | | | | | | 2. FBC11-4.8.4(2), SHOW LANDING SIZE AT TOP AND BOTTOM. | | | | | | 3. FBC11-4.8.5, PROVIDE A HANDRAIL DETAIL AND SHOW | | | HANDRAILS ON THE PLAN WITH ALL REQUIRED DIMENSIONS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-04-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-04-07 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-03-22 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2010-03-24 10:24:14 | UNDER 5 K, BLDG |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2010-03-22 15:21:15 | ANGELA VAUGHN-JONES LOOKED AT PLAN & SAID NO ZONING | | | REVIEW APPLICABLE |
|
|
|