Plan Review Details - Permit 10030516
Plan Review Stops For Permit 10030516
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-03-30 Cont ID  
Sent By jwitmer Date 2010-03-30 Time 08:08 Rev Time 0.66
Received By jwitmer Date 2010-03-30 Time 08:08 Sent To  
Notes
2010-03-30 08:12:20PRINTED NOA 10-0121.10
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S).
  
 ENTRY SIDE LIGHTS NO REFRENECE TO PRODUCT APPROVALS-
 SOLID CBS WALL BEHIND GLAZING, WILL STILL NEED FOR
 INSTALLATION, ATTACHMENT OF FRAME.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-03-29 Cont ID  
Sent By dwise Date 2010-03-29 Time 20:43 Rev Time 0.00
Received By dwise Date 2010-03-29 Time 20:43 Sent To  
Notes
2010-03-29 20:48:27***APPROVED WITH PROVISO***
 THE PLAN INDICATES "FUTURE SPACE" POTENTIALLY FOR
 SEPARATE TENANCY AND SHOWS CIRCUITS PASSING THROUGH THE
 WALL INTO THE SEPARATE TENANCY FOR LIGHTING AND OTHER
 PURPOSES.
 SEPARATE CIRCUITS ARE TYPICALLY REQUIRED TO ENSURE EACH
 TENANT CONTROLS THE ELECTRICAL CIRCUITS IN THEIR OWN
 SPACES. NO TENANT MAY BE DENIED CONTROL OF THEIR OWN
 TENANCY'S ELECTRICAL SYSTEM.
 PLEASE PROVIDE FIELD CLARIFICATION TO THE ELECTRICAL
 INSPECTOR AS TO HOW THE APPLICANT INTENDS TO RESOLVE
 THIS ISSUE.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2010-03-30 Cont ID  
Sent By mcarsill Date 2010-03-30 Time 14:57 Rev Time 0.00
Received By mcarsill Date 2010-03-30 Time 14:57 Sent To  
Notes
2010-03-30 15:00:28 
  
 525 OKEECHOBEE BOUELVARD
 PERMIT NUMBER 10030516
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241.
  
 2. SEPARATE PLANS AND PERMITS REQUIRED FOR FIRE ALARM
 AND FIRE SPRINKLER SYSTEM REMODEL.
  
 3. ALL NEW FIRE DAMPERS ARE TO BE DROP TESTED TO ENSURE
 PROPER OPERATION AFTER INSTALLATION.
  
  
 APPROVED
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION
 (561) 804-4709 PHONE
 (561) 804-4774 FAX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-03-30 Cont ID  
Sent By shill Date 2010-03-30 Time 17:04 Rev Time  
Received By shill Date 2010-03-18 Time   Sent To  
Notes
2010-03-25 15:21:26B-8

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2010-03-25 Cont ID  
Sent By rregueir Date 2010-03-25 Time 16:09 Rev Time 0.00
Received By rregueir Date 2010-03-25 Time 16:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2010-03-29 Cont ID  
Sent By dwise Date 2010-03-29 Time 20:49 Rev Time 0.00
Received By dwise Date 2010-03-29 Time 20:49 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2010-03-23 Cont ID  
Sent By eschneid Date 2010-03-23 Time 14:58 Rev Time 0.20
Received By eschneid Date 2010-03-23 Time 14:58 Sent To  
Notes
2010-03-23 14:58:39SIGN REQUIRES SEPARATE PERMIT.