| Plan Review Stops For Permit 10030036 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-03-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2010-03-04 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2010-03-04 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2010-03-04 11:48:45 | ** | | | VALUE INCREAD BY $4K FOR ELEC AND MECH. | | | SEPARATE PERMIT FOR ELEC MAY REFERENCE THIS AND ONLY | | | PAY TEH SUB PERMIT FEE. | | | NO LOW VOLTAGE INCLUDED IN PLANS. THIS WILL BE | | | SEPARATE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2010-03-24 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-03-24 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-03-24 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2010-03-24 14:16:25 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS PLAN REVIEW HAVE BEEN | | | ADDRESSED; PLAN SHEET M-1 STAMPED, INITIALED, AND | | | DATED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2010-03-08 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-03-08 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-03-08 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2010-03-08 15:40:26 | *****UNSAT***** | | | | | | | | | 1. THE INCORRECT ADDRESS IS LISTED IN THE TITLE BLOCK | | | OF EACH SUBMITTED REVISED SHEET | | | | | | 2. VERIFY SPELLING OF THE FOLLOWING WORDS AS RED | | | CIRCLED ON SHEETS M-1 AND E-1. | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2010-03-22 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-03-18 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-03-18 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2010-03-22 15:10:22 | GAVE TO RON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-03-11 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-03-09 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-03-09 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2010-03-11 08:44:17 | GAVE TO RON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-03-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2010-03-01 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2010-03-01 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2010-03-04 11:47:31 | PLANS WERE ADDED TO EXISTING REVISION IN C12 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2010-03-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-03-24 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-03-24 |
Time |
11:59 |
Sent To |
FIRE |
|
| Notes |
| 2010-03-24 12:05:13 | NOTE | | | SEPARATE PLANS AND PERMIT APPLICATIONS ARE REQUIRED FOR | | | THE FOLLOWING SYSTEMS KITCHEN HOOD , SUPPRESSION , WALK | | | IN COOLER . | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2010-03-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-03-24 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-03-24 |
Time |
10:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2010-03-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2010-03-04 |
Time |
19:24 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2010-03-04 |
Time |
19:04 |
Sent To |
|
|
| Notes |
| 2010-03-04 19:24:27 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. PROVIDE VENTILATION CALCULATIONS FOR THE PROPOSED | | | RECONFIGURED SPACES AND THE PROPOSED NEW USE AND | | | OCCUPANT LOADS PER FBC-EB 709.1 AND FBC-EB 901.2. | | | | | | 2. PROVIDE MISSING DUCT SIZE FOR SUPPLY TRUNK LINE ON | | | EXISTING SOUTH PACKAGE UNIT PER FBC-M 603.1. | | | | | | 3. AUXILIARY DRAIN PROTECTION IS REQUIRED ON NEW | | | PACKAGE UNIT PER FBC-M 307.2.3.1. | | | | | | 4. VENTILATION RATES ARE LIKELY TO INCREASE DUE TO | | | INCREASED OCCUPANT LOADS (COMMENT #1). MOTORIZED VOLUME | | | DAMPERS WITH SHUTOFF DAMPER CONTROLS ARE REQUIRED ON | | | OUTSIDE AIR INTAKES PER FBC-B 13-409.AB.3.3. | | | | | | 5. PROVIDE MANUFACTURER'S DATA SHOW NEW RTU IS DESIGNED | | | FOR WIND RESISTANCE IN ACCORDANCE WITH FBC-M 301.12. | | | | | | NOTE: SEPARATE PLANS AND PERMIT APPLICATIONS ARE | | | REQUIRED FOR THE FOLLOWING SYSTEMS: | | | | | | KITCHEN HOOD | | | HOOD SUPPRESSION | | | WALK-IN COOLER. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|