Plan Review Details - Permit 10020578
Plan Review Stops For Permit 10020578
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2010-07-20 Cont ID  
Sent By rmcdouga Date 2010-07-20 Time 14:43 Rev Time 0.00
Received By rmcdouga Date 2010-07-20 Time 14:43 Sent To Z
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2010-05-27 Cont ID  
Sent By rmcdouga Date 2010-05-27 Time 10:24 Rev Time 0.00
Received By rmcdouga Date 2010-05-27 Time 10:24 Sent To  
Notes
2010-05-27 11:09:192007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) BUILDING COMMENTS FROM THE FIRST REVIEW HAVE NOT
 BEEN ADDRESSED.
  
 2) THE TRUSS DRAWINGS THAT WERE SUBMITTED ARE FOR
 EXPOSURE CATEGORY B AND THE STRUCTURE IS EXPOSURE C.
 SEE COMMENT #1 FROM THE FIRST REVIEW.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-03-15 Cont ID  
Sent By rmcdouga Date 2010-03-15 Time 09:26 Rev Time 0.00
Received By rmcdouga Date 2010-03-15 Time 09:26 Sent To  
Notes
2010-03-15 14:18:272007 FBC W/2009 REVISIONS
 COVERED PORCH ADDITION
  
 DENIED BY BUILDING
  
 1) THE STRUCTURE IS LOCATED IN EXPOSURE CATEGORY 'C'
 AND ON SHEET A4 OF THE PLANS EXPOSURE 'B' IS SPECIFIED.
 SEE THE 2009 REVISIONS TO 2004 FBC SECTION
 R301.2.1.4.3.
  
 2) THE PLANS SPECIFY A 3:12 SLOPE FOR THE ROOF. FBC R
 905.2.7 REQUIRES TWO LAYERS OF UNDERLAYMENT ON THE
 ROOF. PLEASE CORRECT NOTES.
  
 3) FBC R803.2.3.1 REQUIRES THE ROOF SHEATHING TO BE
 FASTENED WITH 8D RING SHANK NAILS. PLEASE CORRECT
 NOTES.
  
 4) FBC R320.7 REQUIRES ROOF DOWNSPOUTS ARE REQUIRED TO
 DISCHARGE A MINIMUM OF 1 FOOT AWAY FROM THE STRUCTURE.
 PLEASE NOTE ON PLANS.
  
 5) FBC R 703.6.3 REQUIRES A BOND BREAK BETWEEN THE
 WATER-RESISTIVE BARRIER AND THE STUCCO. SHOW
 COMPLIANCE.
  
 6) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE
 GAF ROYAL SOVEREIGN SHINGLES ( NOA NO. 07-1012.02 )
 HAVE BEEN SUPERSEDED BY NOA NO. 09-0825.06. PLEASE
 SUBMIT TWO COPIES OF THE CURRENT PRODUCT APPROVALS. DCA
 RULE 9B-72
  
 7) PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD FOR THE PROJECT.
 106.3.3 CITY AMENDMENTS
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-03-08 Cont ID  
Sent By btrobaug Date 2010-03-08 Time 10:49 Rev Time 0.00
Received By btrobaug Date 2010-03-08 Time 09:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2010-07-15 Cont ID  
Sent By vmolina Date 2010-07-15 Time 10:15 Rev Time 0.00
Received By vmolina Date 2010-07-15 Time 10:15 Sent To  
Notes
2010-07-15 10:15:57GAVE TO RM

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-05-24 Cont ID  
Sent By vmolina Date 2010-05-24 Time 12:26 Rev Time 0.00
Received By vmolina Date 2010-05-24 Time 12:26 Sent To  
Notes
2010-05-24 12:27:17GAVE TO MCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-05-24 Cont ID  
Sent By vmolina Date 2010-03-22 Time 12:25 Rev Time 0.00
Received By vmolina Date 2010-03-01 Time 16:25 Sent To  
Notes
2010-03-01 16:28:46SENT TO R3.

Review Stop Z ZONING
Rev No 2 Status P Date 2010-07-22 Cont ID  
Sent By jroach Date 2010-07-22 Time 10:37 Rev Time 0.00
Received By jroach Date 2010-07-22 Time 10:37 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2010-03-22 Cont ID  
Sent By jroach Date 2010-03-22 Time 15:46 Rev Time 0.00
Received By jroach Date 2010-03-22 Time 15:46 Sent To  
Notes
2010-03-22 15:46:27ZONING PLAN REVIEW
  
 PERMIT NO.: 10020578
 ADDRESS: 715 MADDOCK STREET
 CONTRACTOR/CONTACT: GARY DUHANEY
 TELEPHONE NO.: 954.822.8575
 SCOPE OF REVIEW: REAR PORCH ADDITION.
  
 REVIEW STATUS: FAILED
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1) THE PERMIT APPLICATION REFERENCES THE INSTALLATION
 OF A REAR PORCH ADDITION, AS WELL AS A SCREENED
 CARPORT. PLEASE CLARIFY???THE PLANS DO NOT MAKE ANY
 REFERENCE TO A CARPORT.
  
 2) PLEASE INDICATE WHERE THE EXISTING A/C UNIT AT THE
 REAR OF THE PROPERTY WILL BE RELOCATED TO???IT APPEARS
 THAT THE PROPOSED CONSTRUCTION WILL IMPACT THE LOCATION
 OF THE EXISTING UNIT. BE SURE TO INDICATE THE PROPOSED
 SETBACKS FROM THE A/C UNIT TO ALL ADJACENT PROPERTY
 LINES.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 PLANNING AND ZONING DEPARTMENT
 401 CLEMATIS STREET - P.O. BOX 3366
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1435
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.CITYOFWPB.COM
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved