Plan Review Details - Permit 10020553
Plan Review Stops For Permit 10020553
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-11-17 Cont ID  
Sent By shill Date 2010-03-05 Time 17:33 Rev Time 0.00
Received By shill Date 2010-02-25 Time 07:56 Sent To  
Notes
2010-02-25 08:00:40SENT TO PLMG.

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2010-03-05 Cont ID  
Sent By rkussner Date 2010-03-05 Time 14:39 Rev Time 0.00
Received By rkussner Date 2010-03-05 Time 14:39 Sent To  
Notes
2010-03-05 14:39:20***LANDSCAPE REVIEW FAILED***
  
 1. IRRIGATION MUST BE APPROVED THROUGH A SEPARATE
 PERMIT.
  
 2. WEDELIA IS A PROHIBITED SPECIES AND CANNOT BE
 PLANTED.
  
 3. PURSUANT TO SECTION 94-442 (D), PRIVATE LAND AND
 PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK
 SURFACES AND REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN
 SPACE AREAS SHALL BE PLANTED WITH GRASS. GRASS AREAS
 SHALL BE SODDED. SOD MUST BE PLANTED IN THE
 RIGHT-OF-WAY UNLESS YOU OBTAIN WRITTEN APPROVAL FROM
 THE ENGINEERING DEPARTMENT TO USE SHRUBS OR GROUND
 COVER. MULCH IS NOT A SUITABLE GROUND COVER.
  
 4. OPEN SPACE IS CALCULATED BY TAKING THE TOTAL LOT
 AREA AND DEDUCTING THE BUILDING FOOTPRINT. THE
 DIFFERENCE IS THE OPEN SPACE FOR WHICH THE LANDSCAPE
 CALCUATIONS ARE BASED UPON. PLEASE PROVIDE THE TOTAL
 LOT AREA AND THE SQUARE FOOTAGE OF THE STRUCTURES.
  
 5. PURSUANT TO SECTION 94-445 (4) (G) (3) (II), IN ALL
 AREAS, INCLUDING THE RIGHT-OF-WAY) THAT ARE TO BE
 PLANTED IN A CULTIVATED LANDSCAPE, IRRIGATION SYTEMS
 SHALL BE DESIGNED TO HAVE 120 PERCENT COVERAGE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT KUSSNE
 @ (561) 822-1462.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2010-03-02 Cont ID  
Sent By kstevens Date 2010-03-02 Time 08:28 Rev Time 0.00
Received By kstevens Date 2010-03-02 Time 08:28 Sent To L
Notes
2010-03-02 08:30:35ARCHITECT SIGNED/SEALED/DATED PLANS & WATTS N-36 VAC.
 BREAKER OR EQUAL INDICATED FOR IRRIGATION BACKFLOW.

Review Stop P PLUMBING
Rev No 1 Status F Date 2010-03-01 Cont ID  
Sent By kstevens Date 2010-03-01 Time 16:38 Rev Time 0.00
Received By kstevens Date 2010-03-01 Time 16:38 Sent To L
Notes
2010-03-01 16:42:04DENIED
 REFERENCE:
 FBC-2007 PLUMBING
 FBC-2007 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. PLANS DESIGNED BY A DESIGN PROFESSIONAL SHALL BE
 SIGNED, SEALED & DATED BY THE DESIGNER OF RECORD.
 SECTION 106.1.1
  
 2. A SECONDARY BACKFLOW DEVISE IS REQUIRED TO PROTECT
 THE POTABLE WATER IN THE HOUSE FROM THE IRRIGATION
 PIPING. SECTION 608.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 1 Status N Date 2010-03-05 Cont ID  
Sent By rkussner Date 2010-03-05 Time 14:43 Rev Time 0.00
Received By rkussner Date 2010-03-05 Time 14:43 Sent To  
Notes
***NONE***