| Plan Review Stops For Permit 10020525 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-03-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-03-30 |
Time |
16:49 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2010-03-30 |
Time |
16:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-03-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-03-08 |
Time |
15:19 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2010-03-08 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2010-03-08 15:38:01 | BUILDING PLAN REVIEW | | | PERMIT: 10020525 | | | ADD: 5730 CORPORATE WAY# 100 | | | CONT: WILBUR HOBGOOD CONSTRUCTION | | | TEL: (561)718-2096 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | MARCH 08/ 2010 | | | | | | 1) SHEET A-2: | | | | | | 1A) PLANS INDICATE DOOR D-1 TO BE REPLACED, IT IS NOT | | | CLEAR IF THE DOOR IS INTERIOR OR EXTERIOR. IF THE DOOR | | | ONLY OR DOOR AND FRAME WILL BE REPLACED, IF THE | | | CORRIDOR NEEDS TO BE FIRE RATED, OR IF THIS DOOR LEADS | | | TO THE EXTERIOR AND WOULD NEED PRODUCT APPROVALS. | | | ADDITIONAL INFORMATION REQUIRED.106.1.2, TABLE 715.4 OR | | | RULE 9B- 72. | | | | | | 1B) DOOR D-2 INDICATES IT AS A 2'-6" DOORWAY PLEASE | | | REVIEW 1008.1.1 REQUIRES A 32" CLEAR OPENING, SEE | | | EXCEPTION# 3 REQUIRING A 32" CLEAR DOOR. | | | | | | 1C) BOTH DOORS D4 & D12 REQUIRE 18" CLEAR ON THE PULL | | | LATCH SIDE OF TH DOOR: 11-4.13.6. | | | | | | 2) SHEET A-5 DETAIL# 1 BREAK ROOM SINK: 11-4.24.2 | | | HEIGHT. SINKS SHALL BE MOUNTED WITH THE COUNTER OR RIM | | | NO HIGHER THAN 34" ABOVE THE FINISH FLOOR. | | | 11-4.24.3 KNEE CLEARANCE THAT IS AT LEAST 27" HIGH 30" | | | WIDE, AND 19" DEEP SHALL BE PROVIDED UNDERNEATH SINKS. | | | 11-4.24.5 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE AT | | | LEAST 30 INCHES BY 48 INCHES (760 MM BY 1219 MM) | | | COMPLYING WITH SECTION 11-4.2.4 SHALL BE PROVIDED IN | | | FRONT OF A SINK TO ALLOW FORWARD APPROACH. THE CLEAR | | | FLOOR SPACE SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL | | | EXTEND A MAXIMUM OF 19 INCHES (485 MM) UNDERNEATH THE | | | SINK. | | | | | | 3) SHEET A-2 TENANT SEPERATION WALLS DO NOT INDICATE IF | | | WALLS ARE RATED, 708.1 & 708.4. | | | | | | JIM WITMER C. B. O. | | | COMMERCIAL COMBINATION PLAN REVIEW | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | | CUSTOMER SERVICE SURVEY AT: | | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2010-04-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-04-16 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-04-16 |
Time |
11:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2010-04-07 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2010-04-07 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2010-04-07 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2010-04-07 16:09:46 | SEE NOTE #2 FROM FIRST ELECTRICAL REVIEW. FIXTURE | | | SCHEDULE AND BULB SIZE IS NOT WHAT THE CALCULATION | | | CONSISTS OF. | | | | | | JAKE LEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2010-03-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-03-04 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-03-04 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2010-03-04 10:14:35 | | | | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2007 FLORIDA BUILDING CODE, 2009 REVISIONS, 2008 | | | NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING | | | | | | ALL COMMENTS RELATE TO SHEET E-1 & E-2, UNLESS | | | OTHERWISE NOTED. ALL CODE ARTICLES REFERENCED ARE 2008 | | | NEC UNLESS OTHERWISE NOTED. | | | | | | SHOW COMPLIANCE WITH THE FOLLOWING CHAPTER 13 ARTICLES | | | 20070FBC | | | | | | 1} 13-415.AB MANDATORY REQUIREMENTS FOR METHODS A AND B | | | 13-415.AB.1 CONTROLS | | | 13-415.AB.1.1 AUTOMATIC LIGHTING CONTROLS. INTERIOR | | | LIGHTING IN BUILDINGS LARGER THAN 5,000 SQUARE FEET | | | (465 M2) SHALL BE CONTROLLED WITH AN AUTOMATIC CONTROL | | | DEVICE TO SHUT OFF BUILDING LIGHTING IN ALL SPACES. | | | THIS AUTOMATIC CONTROL DEVICE SHALL FUNCTION ON EITHER: | | | 1. A SCHEDULED BASIS USING A TIME-OF-DAY OPERATED | | | CONTROL DEVICE THAT TURNS LIGHTING OFF AT SPECIFIC | | | PROGRAMMED TIMES???AN INDEPENDENT PROGRAM SCHEDULE | | | SHALL BE PROVIDED FOR AREAS OF NO MORE THAN 25,000 | | | SQUARE FEET (2323 M2) BUT NOT MORE THAN ONE FLOOR. | | | 2. AN OCCUPANT SENSOR THAT SHALL TURN LIGHTING OFF | | | WITHIN 30 MINUTES OF AN OCCUPANT LEAVING A SPACE. | | | | | | 2} 13-415.AB.5 INTERIOR LIGHTING POWER, SCOPE. THE | | | INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING OR A | | | SEPARATELY METERED OR PERMITTED PORTION OF A BUILDING | | | SHALL BE DETERMINED BY THE SPACE-BY-SPACE METHOD | | | DESCRIBED IN SECTION 13-415.B.1. TRADE-OFFS OF INTERIOR | | | LIGHTING POWER ALLOWANCE AMONG PORTIONS OF THE BUILDING | | | FOR WHICH A DIFFERENT METHOD OF CALCULATION HAS BEEN | | | USED ARE NOT PERMITTED. THE INSTALLED INTERIOR LIGHTING | | | POWER IDENTIFIED IN ACCORDANCE WITH SECTION | | | 13-415.AB.5.1 SHALL NOT EXCEED THE INTERIOR LIGHTING | | | POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH | | | SECTION13-415.B.1*** SHOW COMPLIANCE ON THE PLAN. THIS | | | CAN BE DEMONSTRATED ON THE PLANS INDICATING THE | | | WATTAGES OF THE LUMINAIRES CHOSEN FOR THE PROJECT | | | CONFORM TO THE DENSITY REQUIREMENTS. INDICATE WATTAGES | | | ON THE FIXTURE SCHEDULE TO CORRELATE WITH THE ONES IN | | | THE CALCULATIONS.408.4 CIRCUIT DIRECTORY OR CIRCUIT | | | IDENTIFICATION | | | EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY | | | IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC | | | PURPOSE OR USE. THE IDENTIFICATION SHALL INCLUDE | | | SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE | | | DISTINGUISHED FROM ALL OTHERS. | | | | | | 3} 408.4 CIRCUIT DIRECTORY OR CIRCUIT IDENTIFICATION | | | EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY | | | IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC | | | PURPOSE OR USE. THE IDENTIFICATION SHALL INCLUDE | | | SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE | | | DISTINGUISHED FROM ALL OTHERS. THE IDENTIFICATION SHALL | | | BE INCLUDED IN A CIRCUIT DIRECTORY THAT IS LOCATED ON | | | THE FACE OR INSIDE OF THE PANEL DOOR IN THE CASE OF A | | | PANELBOARD, AND LOCATED AT EACH SWITCH ON A | | | SWITCHBOARD. | | | | | | 4} PER 700.12(F)(4)-THE BRANCH CIRCUIT FEEDING THE UNIT | | | EQUIPMENT SHALL BE THE SAME BRANCH CIRCUIT AS THAT | | | SERVING THE NORMAL LIGHTING IN THE AREA AND CONNECTED | | | AHEAD OF ANY LOCAL SWITCHES. THE BRANCH CIRCUIT THAT | | | FEEDS UNIT EQUIPMENT SHALL BE CLEARLY IDENTIFIED AT THE | | | DISTRIBUTION PANEL.INDICATE SAME ON THE PLAN, LOCATE | | | THE EMERGENCY LIGHTING. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2010-03-26 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-03-26 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-03-26 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2010-03-26 14:44:17 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS REVIEW HAVE BEEN | | | ADDRESSED; PLAN SHEETS A-2, A-4, & E-2 WERE STAMPED, | | | INITIALED, AND DATED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2010-03-05 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-03-05 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-03-05 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2010-03-05 15:43:55 | *****DENIED***** | | | | | | | | | 1. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS TO COMPLY WITH NFPA 241 - 2004 | | | EDITION. | | | | | | 2. NFPA 101, LIFE SAFETY CODE, SHALL BE REFERENCED. | | | | | | 3. SPECIFY THE INTERIOR FINISH MATERIALS FOR THE NEW | | | WALLS AND/OR CEILINGS IN TERMS OF CLASS A, CLASS B, OR | | | CLASS C. | | | | | | 4. ACCORDING TO THE DOOR AND FRAME SCHEDULE, AS LISTED | | | ON SHEET A-2, IT LISTS ROOM 102 AS A STORAGE ROOM | | | WHEREAS THE PROPOSED FLOOR PLAN HAS IT LISTED AS AN | | | ELECTRICAL ROOM. PLEASE EXPLAIN. | | | | | | 5. IN REFERENCE TO DOOR EIGHT (D-8) AS LISTED ON SHEET | | | A-2, HOW WILL EXITING AT THAT DOOR BE ACOMPLISHED? | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADSDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2010-04-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-04-14 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-04-14 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-03-24 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-03-22 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-03-22 |
Time |
09:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-03-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-03-08 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2010-02-24 |
Time |
12:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2010-04-27 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-04-27 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-04-27 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2010-03-31 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-03-31 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-03-31 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2010-03-31 13:53:40 | PLAN DENIED | | | COMMENT #2 FROM LAST REVIEW WAS NOT ADDRESSED . PLEASE | | | REFER TO SECTION 601.4 BALANCED RETURN AIR . | | | PLAN REVIEW BY HAROLD MOSER 541-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2010-03-03 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2010-03-03 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2010-03-03 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2010-03-03 11:10:02 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. FLOOR PLAN HAS MULTIPLE DUCTS MISSING SIZE AND/OR | | | CFM DESIGNATIONS, INCLUDING FRESH AIR DUCT FOR AHU 2. | | | PROVIDE ALL MISSING INFORMATION PER FBC-M 603.1. | | | | | | 2. RETURN AIR TRANSFER DUCTS ARE NOT SIZED TO MEET THE | | | BALANCED RETURN EXCEPTIONS UNDER FBC-M 601.4. SHOW HOW | | | BALANCED RETURN IS TO BE ACHIEVED IN THESE AREAS. | | | | | | 3. PLAN SHOWS EXISTING FIRE DAMPERS TO REMAIN EVEN | | | THOUGH RATED WALLS ARE REMOVED. FIRE DAMPERS ARE TO BE | | | INSTALLED IN ACCORDANCE WITH THEIR LISTING WITIN A | | | RATED WALL ASSEMBLY. REMOVE OR SHOW HOW A COMPLIANT | | | IJNSTALLATION WILL BE ACHIEVED PER FBC-M 607.2. | | | | | | 4. PLANS REFERENCE THE 2004 FBC. PLEASE UPDATE ALL CODE | | | REFERENCES TO REFLECT THE CODE IN EFFECT AT TIME OF | | | PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2010-04-20 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-04-20 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-04-20 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2010-04-20 14:19:23 | PLUMBING PERMIT REQUIRED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2010-03-29 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-03-29 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-03-29 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2010-03-29 12:30:53 | 2ND REVIEW | | | ACTION: DENIED | | | | | | FBC PLUMBING 2007 | | | | | | 1. WATER CLOSETS ARE NOT VENTED PROPERLY. ADDING A | | | VERTICAL DRY VENT IN THE WALL OF ROOM #110 WOULD BE | | | ACCEPTABLE. | | | 909.1 WET VENT -ONLY THE FIXTURES WITHIN THE BATHROOM | | | GROUPS SHALL CONNECT TO THE WET-VENTED HORIZONTAL | | | BRANCH DRAIN. ANY ADDITIONAL FIXTURES SHALL DISCHARGE | | | DOWNSTREAM OF THE WET VENT. | | | | | | 2. THE COMBINATION DRAIN AND VENT SHOWN FOR THE LAVS, | | | DF, AND SINK IS NOT SIZED - MINIMUM 2 1/2" REQUIRED. | | | 912.3 THE MINIMUM SIZE OF A COMBINATION DRAIN AND VENT | | | PIPE SHALL BE IN ACCORDANCE WITH TABLE 912.3. | | | | | | 3. 603.1 3/4" COLD WATER PIPE IS REQUIRED FOR MORE THAN | | | TWO FIXTURES UP TO 18 FIXTURE UNITS. 604.5 MINIMUM PIPE | | | SIZE FOR THE SINK FIXTURE DROP IS 1/2". | | | | | | REVIEW BY LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | (561) 805-6692 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2010-03-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2010-03-03 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2010-03-02 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2010-03-03 09:05:54 | DENIED | | | REFERENCE: | | | FBC-2007 PLUMBING | | | FBC-2007 BUILDING | | | FBC-2007 CHAPTER 1 | | | FBC-2007 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. ALL SHEETS SHALL INDICATE THE ARCHITECTURAL BUSINESS | | | NUMBER, (CERTIFICATE OF AUTHORIZATION), IN THE TITLE | | | BLOCK OF EACH SHEET. (AA26001535). ALSO THE DATE THE | | | SEAL AND SIGNATURE ARE AFFIXED TO EACH SHEET SHALL BE | | | INDICATED BELOW THE SIGNATURE. FAC 61G1-16.004(2)(5) & | | | FS 481.2055. | | | | | | 2. SHT A-2 A DRINKING FOUNTAIN IS REQUIRED PER TABLE | | | 403.1. (SEE SECTION 410.1). PLEASE SHOW THE LOCATION OF | | | THE REQUIRED D.F. AND SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH SECTION 11-4.15 WITH ALL SUBSECTIONS AS | | | WELL AS SECTION 11-4.1.3(10)(A) PROVISIONS FOR THOSE | | | WHO HAVE DIFFICULTY BENDING OR STOOPING. | | | | | | 3. SHT A-2 RESTROOM 110 SHALL BE ACCESSIBLE. SECTION | | | 11-4.1.3(11). SUBMIT A DETAIL FOR THE TOILET ROOM | | | SHOWING COMPLIANCE WITH SECTIONS 11-4.16, 11-4.19 & | | | 11-4.22 WITH ALL SUBSECTIONS. | | | | | | 4. SHT A-2 THE BREAKROOM SINK SHALL BE ACCESSIBLE. | | | SUBMIT A DETAIL SHOWING COMPLIANCE WITH SECTION 11-4.24 | | | WITH ALL SUBSECTIONS. (NOTE: FORWARD APPROACH CLEAR | | | FLOOR SPACE REQUIRED, CABINET DOORS NOT APPROVED IN | | | CLEAR FLOOR SPACE). | | | | | | 5. SHT A-2 ROOM 113 SHOWS A WATER HEATER IN THE SUPPLY | | | CLOSET. PER NFPA SECTION 422.17, PROTECTION OF | | | COMBUSTIBLE MATERIAL, EACH ELECTRICALLY HEATED | | | APPLIANCE THAT IS INTENDED BY SIZE, WEIGHT, AND SERVICE | | | TO BE LOCATED IN A FIXED POSITION SHALL BE PLACED SO AS | | | TO PROVIDE AMPLE PROTECTION BETWEEN THE APPLIANCE AND | | | ADJACENT COMBUSTIBLE MATERIAL. PLEASE INDICATE THE | | | METHOD OF PROTECTION. | | | | | | 6. SHT A-5 DETAIL 5 SHOWS THE TOILET PAPER DISPENSER TO | | | BE INSTALLED ABOVE THE FLOOR 17" - 19". PER FIGURE 29 | | | THE DISPENSER SHALL BE LOCATED MINIMUM 19" ABOVE THE | | | FLOOR. PLEASE CORRECT THE DETAIL. | | | | | | 7. SHT A-5 DETAIL 4 SHOW COMPLIANCE WITH THE FOLLOWING: | | | A. 11-4.19.2 CLEARANCES | | | B. 11-4.19.4 EXPOSED PIPES & SURFACES | | | C. 11-4.19.5 FAUCETS | | | | | | 8. SHT A-6 FINISH ROOM SCHEDULE. TOILET ROOMS 107 & 110 | | | WALL SCHEDULE SHALL MEET THE REQUIREMENT OF SECTION | | | 1210.2 | | | 1210.2 WALLS. WALLS WITHIN 2 FEET (610 MM) OF URINALS | | | AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, | | | NONABSORBENT SURFACE, TO A HEIGHT OF 4 FEET (1219 MM) | | | ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL ELEMENTS, | | | THE MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE | | | THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. -- PLANS | | | SHOW PAINTED WALLS WHICH DOES NOT COMPLY. PLEASE | | | INDICATE METHOD OF COMPLIANCE. | | | | | | 9. SHT P-1 A WATER ISOMETRIC RISER DIAGRAM IS REQUIRED | | | PER SECTION 106.3.5.1.3. PLEASE SUBMIT. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2010-03-02 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2010-03-02 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2010-03-02 |
Time |
14:15 |
Sent To |
|
|
| Notes |
|
|