Plan Review Details - Permit 10020525
Plan Review Stops For Permit 10020525
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-03-30 Cont ID  
Sent By jwitmer Date 2010-03-30 Time 16:49 Rev Time 0.77
Received By jwitmer Date 2010-03-30 Time 16:49 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-03-08 Cont ID  
Sent By jwitmer Date 2010-03-08 Time 15:19 Rev Time 0.77
Received By jwitmer Date 2010-03-08 Time 11:48 Sent To  
Notes
2010-03-08 15:38:01BUILDING PLAN REVIEW
 PERMIT: 10020525
 ADD: 5730 CORPORATE WAY# 100
 CONT: WILBUR HOBGOOD CONSTRUCTION
 TEL: (561)718-2096
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
 MARCH 08/ 2010
  
 1) SHEET A-2:
  
 1A) PLANS INDICATE DOOR D-1 TO BE REPLACED, IT IS NOT
 CLEAR IF THE DOOR IS INTERIOR OR EXTERIOR. IF THE DOOR
 ONLY OR DOOR AND FRAME WILL BE REPLACED, IF THE
 CORRIDOR NEEDS TO BE FIRE RATED, OR IF THIS DOOR LEADS
 TO THE EXTERIOR AND WOULD NEED PRODUCT APPROVALS.
 ADDITIONAL INFORMATION REQUIRED.106.1.2, TABLE 715.4 OR
 RULE 9B- 72.
  
 1B) DOOR D-2 INDICATES IT AS A 2'-6" DOORWAY PLEASE
 REVIEW 1008.1.1 REQUIRES A 32" CLEAR OPENING, SEE
 EXCEPTION# 3 REQUIRING A 32" CLEAR DOOR.
  
 1C) BOTH DOORS D4 & D12 REQUIRE 18" CLEAR ON THE PULL
 LATCH SIDE OF TH DOOR: 11-4.13.6.
  
 2) SHEET A-5 DETAIL# 1 BREAK ROOM SINK: 11-4.24.2
 HEIGHT. SINKS SHALL BE MOUNTED WITH THE COUNTER OR RIM
 NO HIGHER THAN 34" ABOVE THE FINISH FLOOR.
 11-4.24.3 KNEE CLEARANCE THAT IS AT LEAST 27" HIGH 30"
 WIDE, AND 19" DEEP SHALL BE PROVIDED UNDERNEATH SINKS.
 11-4.24.5 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE AT
 LEAST 30 INCHES BY 48 INCHES (760 MM BY 1219 MM)
 COMPLYING WITH SECTION 11-4.2.4 SHALL BE PROVIDED IN
 FRONT OF A SINK TO ALLOW FORWARD APPROACH. THE CLEAR
 FLOOR SPACE SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL
 EXTEND A MAXIMUM OF 19 INCHES (485 MM) UNDERNEATH THE
 SINK.
  
 3) SHEET A-2 TENANT SEPERATION WALLS DO NOT INDICATE IF
 WALLS ARE RATED, 708.1 & 708.4.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2010-04-16 Cont ID  
Sent By btrobaug Date 2010-04-16 Time 11:58 Rev Time 0.00
Received By btrobaug Date 2010-04-16 Time 11:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2010-04-07 Cont ID  
Sent By jleahy Date 2010-04-07 Time 16:08 Rev Time 0.00
Received By jleahy Date 2010-04-07 Time 16:08 Sent To  
Notes
2010-04-07 16:09:46SEE NOTE #2 FROM FIRST ELECTRICAL REVIEW. FIXTURE
 SCHEDULE AND BULB SIZE IS NOT WHAT THE CALCULATION
 CONSISTS OF.
  
 JAKE LEAHY

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2010-03-04 Cont ID  
Sent By btrobaug Date 2010-03-04 Time 10:52 Rev Time 0.00
Received By btrobaug Date 2010-03-04 Time 09:25 Sent To  
Notes
2010-03-04 10:14:35 
  
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA BUILDING CODE, 2009 REVISIONS, 2008
 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING
  
 ALL COMMENTS RELATE TO SHEET E-1 & E-2, UNLESS
 OTHERWISE NOTED. ALL CODE ARTICLES REFERENCED ARE 2008
 NEC UNLESS OTHERWISE NOTED.
  
 SHOW COMPLIANCE WITH THE FOLLOWING CHAPTER 13 ARTICLES
 20070FBC
  
 1} 13-415.AB MANDATORY REQUIREMENTS FOR METHODS A AND B
 13-415.AB.1 CONTROLS
 13-415.AB.1.1 AUTOMATIC LIGHTING CONTROLS. INTERIOR
 LIGHTING IN BUILDINGS LARGER THAN 5,000 SQUARE FEET
 (465 M2) SHALL BE CONTROLLED WITH AN AUTOMATIC CONTROL
 DEVICE TO SHUT OFF BUILDING LIGHTING IN ALL SPACES.
 THIS AUTOMATIC CONTROL DEVICE SHALL FUNCTION ON EITHER:
 1. A SCHEDULED BASIS USING A TIME-OF-DAY OPERATED
 CONTROL DEVICE THAT TURNS LIGHTING OFF AT SPECIFIC
 PROGRAMMED TIMES???AN INDEPENDENT PROGRAM SCHEDULE
 SHALL BE PROVIDED FOR AREAS OF NO MORE THAN 25,000
 SQUARE FEET (2323 M2) BUT NOT MORE THAN ONE FLOOR.
 2. AN OCCUPANT SENSOR THAT SHALL TURN LIGHTING OFF
 WITHIN 30 MINUTES OF AN OCCUPANT LEAVING A SPACE.
  
 2} 13-415.AB.5 INTERIOR LIGHTING POWER, SCOPE. THE
 INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING OR A
 SEPARATELY METERED OR PERMITTED PORTION OF A BUILDING
 SHALL BE DETERMINED BY THE SPACE-BY-SPACE METHOD
 DESCRIBED IN SECTION 13-415.B.1. TRADE-OFFS OF INTERIOR
 LIGHTING POWER ALLOWANCE AMONG PORTIONS OF THE BUILDING
 FOR WHICH A DIFFERENT METHOD OF CALCULATION HAS BEEN
 USED ARE NOT PERMITTED. THE INSTALLED INTERIOR LIGHTING
 POWER IDENTIFIED IN ACCORDANCE WITH SECTION
 13-415.AB.5.1 SHALL NOT EXCEED THE INTERIOR LIGHTING
 POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH
 SECTION13-415.B.1*** SHOW COMPLIANCE ON THE PLAN. THIS
 CAN BE DEMONSTRATED ON THE PLANS INDICATING THE
 WATTAGES OF THE LUMINAIRES CHOSEN FOR THE PROJECT
 CONFORM TO THE DENSITY REQUIREMENTS. INDICATE WATTAGES
 ON THE FIXTURE SCHEDULE TO CORRELATE WITH THE ONES IN
 THE CALCULATIONS.408.4 CIRCUIT DIRECTORY OR CIRCUIT
 IDENTIFICATION
 EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY
 IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC
 PURPOSE OR USE. THE IDENTIFICATION SHALL INCLUDE
 SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE
 DISTINGUISHED FROM ALL OTHERS.
  
 3} 408.4 CIRCUIT DIRECTORY OR CIRCUIT IDENTIFICATION
 EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY
 IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC
 PURPOSE OR USE. THE IDENTIFICATION SHALL INCLUDE
 SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE
 DISTINGUISHED FROM ALL OTHERS. THE IDENTIFICATION SHALL
 BE INCLUDED IN A CIRCUIT DIRECTORY THAT IS LOCATED ON
 THE FACE OR INSIDE OF THE PANEL DOOR IN THE CASE OF A
 PANELBOARD, AND LOCATED AT EACH SWITCH ON A
 SWITCHBOARD.
  
 4} PER 700.12(F)(4)-THE BRANCH CIRCUIT FEEDING THE UNIT
 EQUIPMENT SHALL BE THE SAME BRANCH CIRCUIT AS THAT
 SERVING THE NORMAL LIGHTING IN THE AREA AND CONNECTED
 AHEAD OF ANY LOCAL SWITCHES. THE BRANCH CIRCUIT THAT
 FEEDS UNIT EQUIPMENT SHALL BE CLEARLY IDENTIFIED AT THE
 DISTRIBUTION PANEL.INDICATE SAME ON THE PLAN, LOCATE
 THE EMERGENCY LIGHTING.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2010-03-26 Cont ID  
Sent By mawillia Date 2010-03-26 Time 14:44 Rev Time 0.00
Received By mawillia Date 2010-03-26 Time 14:31 Sent To  
Notes
2010-03-26 14:44:17*****APPROVED*****
  
 THE COMMENTS FROM THE PREVIOUS REVIEW HAVE BEEN
 ADDRESSED; PLAN SHEETS A-2, A-4, & E-2 WERE STAMPED,
 INITIALED, AND DATED.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2010-03-05 Cont ID  
Sent By mawillia Date 2010-03-05 Time 15:44 Rev Time 0.00
Received By mawillia Date 2010-03-05 Time 14:52 Sent To  
Notes
2010-03-05 15:43:55*****DENIED*****
  
  
 1. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS TO COMPLY WITH NFPA 241 - 2004
 EDITION.
  
 2. NFPA 101, LIFE SAFETY CODE, SHALL BE REFERENCED.
  
 3. SPECIFY THE INTERIOR FINISH MATERIALS FOR THE NEW
 WALLS AND/OR CEILINGS IN TERMS OF CLASS A, CLASS B, OR
 CLASS C.
  
 4. ACCORDING TO THE DOOR AND FRAME SCHEDULE, AS LISTED
 ON SHEET A-2, IT LISTS ROOM 102 AS A STORAGE ROOM
 WHEREAS THE PROPOSED FLOOR PLAN HAS IT LISTED AS AN
 ELECTRICAL ROOM. PLEASE EXPLAIN.
  
 5. IN REFERENCE TO DOOR EIGHT (D-8) AS LISTED ON SHEET
 A-2, HOW WILL EXITING AT THAT DOOR BE ACOMPLISHED?
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING HOW/WHERE EACH ITEM WAS ADSDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2010-04-14 Cont ID  
Sent By shill Date 2010-04-14 Time 13:42 Rev Time 0.00
Received By shill Date 2010-04-14 Time 13:42 Sent To  
Notes
2010-04-14 13:42:37B 11
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-03-24 Cont ID  
Sent By lmartine Date 2010-03-22 Time 09:59 Rev Time 0.00
Received By lmartine Date 2010-03-22 Time 09:59 Sent To  
Notes
2010-03-24 09:59:27B--7

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-03-08 Cont ID  
Sent By jwitmer Date 2010-03-08 Time 15:19 Rev Time 0.00
Received By jwitmer Date 2010-02-24 Time 12:14 Sent To  
Notes
2010-02-24 12:21:44B-13

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2010-04-27 Cont ID  
Sent By hmoser Date 2010-04-27 Time 14:02 Rev Time 0.00
Received By hmoser Date 2010-04-27 Time 13:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2010-03-31 Cont ID  
Sent By hmoser Date 2010-03-31 Time 13:49 Rev Time 0.00
Received By hmoser Date 2010-03-31 Time 13:49 Sent To  
Notes
2010-03-31 13:53:40PLAN DENIED
 COMMENT #2 FROM LAST REVIEW WAS NOT ADDRESSED . PLEASE
 REFER TO SECTION 601.4 BALANCED RETURN AIR .
 PLAN REVIEW BY HAROLD MOSER 541-805-6732

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2010-03-03 Cont ID  
Sent By rregueir Date 2010-03-03 Time 11:10 Rev Time 0.00
Received By rregueir Date 2010-03-03 Time 11:04 Sent To  
Notes
2010-03-03 11:10:02REVIEW #: 1ST
 ACTION: DENIED
  
 FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. FLOOR PLAN HAS MULTIPLE DUCTS MISSING SIZE AND/OR
 CFM DESIGNATIONS, INCLUDING FRESH AIR DUCT FOR AHU 2.
 PROVIDE ALL MISSING INFORMATION PER FBC-M 603.1.
  
 2. RETURN AIR TRANSFER DUCTS ARE NOT SIZED TO MEET THE
 BALANCED RETURN EXCEPTIONS UNDER FBC-M 601.4. SHOW HOW
 BALANCED RETURN IS TO BE ACHIEVED IN THESE AREAS.
  
 3. PLAN SHOWS EXISTING FIRE DAMPERS TO REMAIN EVEN
 THOUGH RATED WALLS ARE REMOVED. FIRE DAMPERS ARE TO BE
 INSTALLED IN ACCORDANCE WITH THEIR LISTING WITIN A
 RATED WALL ASSEMBLY. REMOVE OR SHOW HOW A COMPLIANT
 IJNSTALLATION WILL BE ACHIEVED PER FBC-M 607.2.
  
 4. PLANS REFERENCE THE 2004 FBC. PLEASE UPDATE ALL CODE
 REFERENCES TO REFLECT THE CODE IN EFFECT AT TIME OF
 PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2010-04-20 Cont ID  
Sent By lwagner Date 2010-04-20 Time 14:16 Rev Time 0.00
Received By lwagner Date 2010-04-20 Time 14:11 Sent To  
Notes
2010-04-20 14:19:23PLUMBING PERMIT REQUIRED

Review Stop P PLUMBING
Rev No 2 Status F Date 2010-03-29 Cont ID  
Sent By lwagner Date 2010-03-29 Time 11:30 Rev Time 0.00
Received By lwagner Date 2010-03-29 Time 10:27 Sent To  
Notes
2010-03-29 12:30:532ND REVIEW
 ACTION: DENIED
  
 FBC PLUMBING 2007
  
 1. WATER CLOSETS ARE NOT VENTED PROPERLY. ADDING A
 VERTICAL DRY VENT IN THE WALL OF ROOM #110 WOULD BE
 ACCEPTABLE.
 909.1 WET VENT -ONLY THE FIXTURES WITHIN THE BATHROOM
 GROUPS SHALL CONNECT TO THE WET-VENTED HORIZONTAL
 BRANCH DRAIN. ANY ADDITIONAL FIXTURES SHALL DISCHARGE
 DOWNSTREAM OF THE WET VENT.
  
 2. THE COMBINATION DRAIN AND VENT SHOWN FOR THE LAVS,
 DF, AND SINK IS NOT SIZED - MINIMUM 2 1/2" REQUIRED.
 912.3 THE MINIMUM SIZE OF A COMBINATION DRAIN AND VENT
 PIPE SHALL BE IN ACCORDANCE WITH TABLE 912.3.
  
 3. 603.1 3/4" COLD WATER PIPE IS REQUIRED FOR MORE THAN
 TWO FIXTURES UP TO 18 FIXTURE UNITS. 604.5 MINIMUM PIPE
 SIZE FOR THE SINK FIXTURE DROP IS 1/2".
  
 REVIEW BY LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 (561) 805-6692
 FAX (561) 653-2692
 E-MAIL [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2010-03-03 Cont ID  
Sent By kstevens Date 2010-03-03 Time 08:33 Rev Time 0.00
Received By kstevens Date 2010-03-02 Time 16:53 Sent To  
Notes
2010-03-03 09:05:54DENIED
 REFERENCE:
 FBC-2007 PLUMBING
 FBC-2007 BUILDING
 FBC-2007 CHAPTER 1
 FBC-2007 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. ALL SHEETS SHALL INDICATE THE ARCHITECTURAL BUSINESS
 NUMBER, (CERTIFICATE OF AUTHORIZATION), IN THE TITLE
 BLOCK OF EACH SHEET. (AA26001535). ALSO THE DATE THE
 SEAL AND SIGNATURE ARE AFFIXED TO EACH SHEET SHALL BE
 INDICATED BELOW THE SIGNATURE. FAC 61G1-16.004(2)(5) &
 FS 481.2055.
  
 2. SHT A-2 A DRINKING FOUNTAIN IS REQUIRED PER TABLE
 403.1. (SEE SECTION 410.1). PLEASE SHOW THE LOCATION OF
 THE REQUIRED D.F. AND SUBMIT A DETAIL SHOWING
 COMPLIANCE WITH SECTION 11-4.15 WITH ALL SUBSECTIONS AS
 WELL AS SECTION 11-4.1.3(10)(A) PROVISIONS FOR THOSE
 WHO HAVE DIFFICULTY BENDING OR STOOPING.
  
 3. SHT A-2 RESTROOM 110 SHALL BE ACCESSIBLE. SECTION
 11-4.1.3(11). SUBMIT A DETAIL FOR THE TOILET ROOM
 SHOWING COMPLIANCE WITH SECTIONS 11-4.16, 11-4.19 &
 11-4.22 WITH ALL SUBSECTIONS.
  
 4. SHT A-2 THE BREAKROOM SINK SHALL BE ACCESSIBLE.
 SUBMIT A DETAIL SHOWING COMPLIANCE WITH SECTION 11-4.24
 WITH ALL SUBSECTIONS. (NOTE: FORWARD APPROACH CLEAR
 FLOOR SPACE REQUIRED, CABINET DOORS NOT APPROVED IN
 CLEAR FLOOR SPACE).
  
 5. SHT A-2 ROOM 113 SHOWS A WATER HEATER IN THE SUPPLY
 CLOSET. PER NFPA SECTION 422.17, PROTECTION OF
 COMBUSTIBLE MATERIAL, EACH ELECTRICALLY HEATED
 APPLIANCE THAT IS INTENDED BY SIZE, WEIGHT, AND SERVICE
 TO BE LOCATED IN A FIXED POSITION SHALL BE PLACED SO AS
 TO PROVIDE AMPLE PROTECTION BETWEEN THE APPLIANCE AND
 ADJACENT COMBUSTIBLE MATERIAL. PLEASE INDICATE THE
 METHOD OF PROTECTION.
  
 6. SHT A-5 DETAIL 5 SHOWS THE TOILET PAPER DISPENSER TO
 BE INSTALLED ABOVE THE FLOOR 17" - 19". PER FIGURE 29
 THE DISPENSER SHALL BE LOCATED MINIMUM 19" ABOVE THE
 FLOOR. PLEASE CORRECT THE DETAIL.
  
 7. SHT A-5 DETAIL 4 SHOW COMPLIANCE WITH THE FOLLOWING:
 A. 11-4.19.2 CLEARANCES
 B. 11-4.19.4 EXPOSED PIPES & SURFACES
 C. 11-4.19.5 FAUCETS
  
 8. SHT A-6 FINISH ROOM SCHEDULE. TOILET ROOMS 107 & 110
 WALL SCHEDULE SHALL MEET THE REQUIREMENT OF SECTION
 1210.2
 1210.2 WALLS. WALLS WITHIN 2 FEET (610 MM) OF URINALS
 AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD,
 NONABSORBENT SURFACE, TO A HEIGHT OF 4 FEET (1219 MM)
 ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL ELEMENTS,
 THE MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE
 THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. -- PLANS
 SHOW PAINTED WALLS WHICH DOES NOT COMPLY. PLEASE
 INDICATE METHOD OF COMPLIANCE.
  
 9. SHT P-1 A WATER ISOMETRIC RISER DIAGRAM IS REQUIRED
 PER SECTION 106.3.5.1.3. PLEASE SUBMIT.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 1 Status N Date 2010-03-02 Cont ID  
Sent By kdfreema Date 2010-03-02 Time 14:15 Rev Time 0.00
Received By kdfreema Date 2010-03-02 Time 14:15 Sent To  
Notes
***NONE***