Plan Review Details - Permit 10020467
| Plan Review Stops For Permit 10020467 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2010-03-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-03-25 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-03-25 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2010-03-25 08:39:16 | PROVISO - SMS | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2010-03-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-03-23 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-03-23 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2010-03-23 16:22:25 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. THE NEW PLAN SHOWS 150MPH EXPOSURE B. PLEASE REVISE. | | | | | | 2. PLEASE CLARIFY GIRT SIZING. IF NECESSARY, CIRCLE ON | | | THE CHARTS SUBMITTED. THE FIRST SUBMITTAL INCLUDED A | | | SHEET WHICH PROVIDED GIRT INFORMATION; THIS WAS NOT | | | PROVIDED IN A REVISED FORM FOR EXPOSURE C. HOWEVER, THE | | | LOAD WIDTH APPEARS TOO SHORT (ROUNDING DOWN RATHER THAN | | | ROUNDING UP) AND THE TYPE OF CHAIR RAIL PROPOSED IS NOT | | | CLEAR, ONLY SIZE, BUT NOT ALL SIZES COMPLY. FOR | | | INSTANCE, 4'4" LOAD WITDTH, 7'10" SPAN, 2X3. THE NEW | | | PLAN DOES NOT SPECIFY WHICH 2X3; SMS IS SPECIFIED ON A | | | SHEET FROM THE FIRST SUBMITTAL WHICH SPECIFIES EXPOSURE | | | B. PLEASE REVISE THE PLAN TO INCLUDE THE TYPE OF GIRT | | | PROPOSED. | | | | | | 4'4" LOAD WIDTH - IT APPEARS THAT THIS SHOULD BE 4'5". | | | IT IS NOT CLEAR WHY YOU HAD SPECIFIED A 7'10" SPAN, | | | ISN'T THIS AN 8' SPAN? YOU CANNOT DEDUCT FOR THE | | | MEMBERS, THIS DIMENSION SHOULD GO FROM STRUCTURE/CENTER | | | OF POST TO STRUCTURE/CENTER OF POST. 2X3 SMS REQUIRED, | | | BUT "SMS" WAS NOT SPECIFIED ON ANY OF THE REVISED | | | SHEETS. IT IS NOT CLEAR HOW SPANS HAVE BEEN DETERMINED. | | | | | | FOR THE 3'11"/5' LOAD WIDTH/SPAN, 2X2 SPECIFIED. SMS | | | NOT SPECIFIED, BUT APPEARS TO BE REQUIRED. PLEASE | | | REVISE PLAN TO STATE SPECIFIC SIZE IF ALL DO NOT | | | COMPLY. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-03-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-03-09 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-03-09 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2010-03-09 14:43:56 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. THIS PARCEL IS IN THE TRANSITION ZONE BETWEEN | | | EXPOSURE BAND EXPOSURE C, AND THEREFORE MUST BE | | | DESIGNED AS EXPOSURE C UNLESS INTERPOLATED BY AN | | | ENGINEER FBC1609, FBC R301.2.1.4. NOTE THAT THE CODE | | | CHANGED EFFECTIVE MARCH 1, 2009. | | | | | | ***THIS IS A COURTESY NOTICE - IN THE FUTURE, PLANS | | | WILL NOT BE DENIED BUT WILL BE ISSUED WITH PROVISO THAT | | | THE PLANS BE REVISED PRIOR TO FIRST INSPECTION, WITH | | | REVISION FEES.** | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-03-22 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-03-18 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-03-18 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2010-03-22 13:52:57 | GAVE TO SAMANTHA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-03-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-03-09 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-02-23 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2010-02-23 08:45:34 | TO ZONING IN BOX./WRT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2010-03-04 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2010-03-04 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2010-03-04 |
Time |
15:37 |
Sent To |
B |
|
| Notes |
| 2010-03-04 15:40:28 | PLANNING AND ZONING **** PASSED WITH PROVISO, THE | | | SCREEN ENCLOSURE IS TO THE REAR EDGE (SOUTH EDGE) OF | | | EXISTING HOME. **** | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] |
|
|
|