| Plan Review Stops For Permit 10020403 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-02-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-02-22 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-02-22 |
Time |
11:11 |
Sent To |
PC |
|
| Notes |
| 2010-02-22 11:56:19 | REROOF REVISION CHECKLIST: | | | | | | 1- PRODUCT APPROVAL FL1654-R6 SUBMITTED IS MISSING THE | | | TECHNICAL INFORMATION SHOWING SPECIFIC APPROVED | | | ASSEMBLY TO BE INSTALLED. PROVIDE INFORMATION SHOWING | | | SPECIFIC APPROVED ASSEMBLY TO BE INSTALLED TO VERIFY | | | COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. R301 OF | | | 2007 FLORIDA RESIDENTIAL CODE. | | | ***NOTE: IF SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES REQUIRED BY SEC. R301, THEN NEED TO PROVIDE | | | SIGNED AND SEALED RAS 117 CALCULATIONS AS REQUIRED BY | | | GENERAL NOTE #6 OF THE PRODUCT APPROVAL SUBMITTED. | | | ALSO, CHECK GENERAL NOTE #7 FOR BONDED SYSTEMS. NAIL | | | ENHANCING IS NOT ALLOWED. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-02-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-02-22 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-02-22 |
Time |
11:12 |
Sent To |
|
|
| Notes |
|
|
|