| 2010-02-24 15:19:13 | BUILDING PLAN REVIEW |
| | PERMIT: 09100379 |
| | REVISION: 10020397 |
| | ADD: 500 BELVEDERE SUITE 642 |
| | CONT: QUAD M CONSTRUCTION |
| | TEL: (561)722-2303 |
| | |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW REVISION |
| | ACTION: DENIED |
| | |
| | 1) THE ELECTRICAL PLANS INDICATE A DANCE AREA AND |
| | NIGHTCLUB, PLEASE UPDATE THE ARCHITECTURAL SHEETS': |
| | |
| | A-1.0 PROPOSED FLOOR PLAN |
| | |
| | A-2.0 LIFE SAFETY PLAN AND PROPOSED OCCUPANT LOAD |
| | ISSUED PLANS INDICATE A OCCUPANCY OF 81. |
| | |
| | A-3.0 FURNATURE AND EGRESS PLANS. |
| | |
| | 2) THE LAST KNOWN USE (OCCUPATIONAL LICENSE) MADE BEEN |
| | A RESTARAUNT (40 SEATS) AND BAKERY WWITH THE CHANGE OF |
| | OCCUPANCY TO A RESTARAUNT (A2) OCCUPANCY THIS ENACTED |
| | CHAPTER 9 OF THE EXISTING BUILDING CODE. |
| | |
| | 2A) EXISTING BUILDING CODE: SECTION 904 FIRE PROTECTION |
| | 904.1 GENERAL. FIRE PROTECTION REQUIREMENTS OF SECTION |
| | 912 SHALL APPLY WHERE A BUILDING OR PORTIONS THEREOF |
| | UNDERGO A CHANGE OF OCCUPANCY CLASSIFICATION. |
| | |
| | EXISTING BUILDING CODE; 912.2.1 FIRE SPRINKLER SYSTEM. |
| | WHERE A CHANGE IN OCCUPANCY CLASSIFICATION OCCURS THAT |
| | REQUIRES AN AUTOMATIC FIRE SPRINKLER SYSTEM TO BE |
| | PROVIDED BASED ON THE NEW OCCUPANCY IN ACCORDANCE WITH |
| | CHAPTER 9 OF THE FLORIDA BUILDING CODE, BUILDING , SUCH |
| | SYSTEM SHALL BE PROVIDED THROUGHOUT THE AREA WHERE THE |
| | CHANGE OF OCCUPANCY OCCURS. |
| | |
| | 2007 FBC- BUILDING. 903.2.1.2 GROUP A-2. AN AUTOMATIC |
| | SPRINKLER SYSTEM SHALL BE PROVIDED FOR GROUP A-2 |
| | OCCUPANCIES WHERE ONE OF THE FOLLOWING CONDITIONS |
| | EXISTS: |
| | 1. THE FIRE AREA EXCEEDS 5,000 SQUARE FEET (464.5 M2). |
| | 2. THE FIRE AREA HAS AN OCCUPANT LOAD OF 100 OR MORE. |
| | 3. THE FIRE AREA IS LOCATED ON A FLOOR OTHER THAN THE |
| | LEVEL OF EXIT DISCHARGE. |
| | 4. NIGHTCLUBS OR SIMILAR USAGE WHEN OCCUPANT LOAD IS |
| | 100 OR MORE. |
| | |
| | 3) EXISTING BUILDING CODE, SECTION 905 MEANS OF EGRESS |
| | 905.1 GENERAL. MEANS OF EGRESS IN PORTIONS OF BUILDINGS |
| | UNDERGOING A CHANGE OF OCCUPANCY CLASSIFICATION SHALL |
| | COMPLY WITH SECTION 912. |
| | 912.4.1 MEANS OF EGRESS FOR CHANGE TO HIGHER HAZARD |
| | CATEGORY. WHEN A CHANGE OF OCCUPANCY GROUP IS MADE TO A |
| | HIGHER HAZARD CATEGORY (LOWER NUMBER) AS SHOWN IN TABLE |
| | 912.4, THE MEANS OF EGRESS SHALL COMPLY WITH THE |
| | REQUIREMENTS OF CHAPTER 10 OF THE FLORIDA BUILDING |
| | CODE, BUILDING . |
| | |
| | |
| | 4) EXISTING BUILDING CODE, SECTION 906 ACCESSIBILITY |
| | 906.1 GENERAL. ACCESSIBILITY IN PORTIONS OF BUILDINGS |
| | UNDERGOING A CHANGE OF OCCUPANCY CLASSIFICATION SHALL |
| | COMPLY WITH CHAPTER 11 OF THE FLORIDA BUILDING CODE, |
| | BUILDING. |
| | 912.8 ACCESSIBILITY. EXISTING BUILDINGS OR PORTIONS |
| | THEREOF THAT UNDERGO A CHANGE OF GROUP OR OCCUPANCY |
| | CLASSIFICATION SHALL COMPLY WITH CHAPTER 11 OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | JIM WITMER C. B. O. |
| | COMMERCIAL COMBINATION PLAN REVIEW |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |