Plan Review Details - Permit 10020285
Plan Review Stops For Permit 10020285
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-02-24 Cont ID  
Sent By jwitmer Date 2010-02-24 Time 11:03 Rev Time 1.30
Received By jwitmer Date 2010-02-24 Time 08:59 Sent To  
Notes
2010-02-24 11:04:13BUILDING PLAN REVIEW
 PERMIT: 10020285
 ADD: 1501 N AUSTRALIAN AVE
 CONT: AYA SOLUTIONS INC.
 TEL: (305)792-6720
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S).
  
 1) FL BLDG CODE- EXISTING BUILDING CODE SECTION 706.1-
 A BUILDING, FACILITY, OR ELEMENT THAT IS ALTERED SHALL
 COMPLY WITH CHAPTER 11 OF THE FLORIDA BUILDING CODE,
 BUILDING.
  
 11-4.1.6 (2) ALTERATIONS TO AN AREA CONTAINING A
 PRIMARY FUNCTION AREA.
 ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL TO ALTERED AREAS SHALL BE DEEMED
 DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE
 COST EXCEEDS 20 PERCENT OF THE COST OF THE ALTERATION
 TO THE PRIMARY FUNCTION AREA.
  
 DUTY TO PROVIDE ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY.
  
 (1) WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE
 PATH OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS
 DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION,
 THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE
 EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING
 DISPROPORTIONATE COSTS.
 (2)(A) IN CHOOSING WHICH ACCESSIBLE ELEMENTS TO
 PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE ELEMENTS
 THAT WILL PROVIDE THE GREATEST ACCESS, IN THE FOLLOWING
 ORDER:
 (I) AN ACCESSIBLE ENTRANCE;
 (II) AN ACCESSIBLE ROUTE TO THE ALTERED AREA:
 (III) AT LEAST ONE ACCESSIBLE RESTROOM FOR EACH SEX OR
 A SINGLE UNISEX RESTROOM:
  
 1A) WITHIN BOTH THE WOMEN???S & MEN???S RESTROOMS THE
 PLANS APPEAR TO HAVE AN ACCESSIBLE STALL AND WHAT
 APPEARS TO BE A AMBULATORY ACCESSIBLE STALL WITH ONLY
 ONE GRAB BAR. BY CODE THESE STALLS DO NOT NEED TO MEET
 THIS REQUIREMENT. IF PROVIDED THEY MUST MEET THE
 REQUIREMENTS OF GRAB BARS ON BOTH SIDES, PLEASE SEE
 FIGURE 30 (B) FOR THE 36??? WIDE STALL AND THE REQUIRED
 DEPTH REQUIREMENTS FOR BOTH, FLOOR MOUNTED OR WALL
 MOUNTED FIXTURES.
 1B) THE SECOND ISSUE WOULD BE THE DOORS WOULD BE
 REQUIRED TO BE 32??? CLEAR OPENINGS AND OUT SWING
 DOORS, SEE FIGURE 30 (B) ALTERNATE STALLS.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-02-23 Cont ID  
Sent By btrobaug Date 2010-02-23 Time 12:29 Rev Time 0.00
Received By btrobaug Date 2010-02-23 Time 12:18 Sent To  
Notes
2010-02-23 12:29:40ELECTRICAL PERMIT REQUIRED./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-02-24 Cont ID  
Sent By jwitmer Date 2010-02-24 Time 10:39 Rev Time 0.00
Received By jwitmer Date 2010-02-11 Time 15:21 Sent To  
Notes
2010-02-16 15:22:05B--13

Review Stop P PLUMBING
Rev No 1 Status N Date 2010-02-18 Cont ID  
Sent By kstevens Date 2010-02-18 Time 16:34 Rev Time 0.00
Received By kstevens Date 2010-02-18 Time 16:34 Sent To  
Notes
2010-02-18 16:34:36SEPARATE PLUMBING PERMIT REQUIRED.

Review Stop Z ZONING
Rev No 1 Status N Date 2010-02-24 Cont ID  
Sent By jwitmer Date 2010-02-24 Time 11:56 Rev Time 0.00
Received By jwitmer Date 2010-02-24 Time 11:56 Sent To  
Notes
2010-02-24 11:58:072-24-10 I SPOKE WITH AMY STELLY WILL NOT NEED ZONING
 REVIEW.