2010-02-24 11:41:48BUILDING PLAN REVIEW
 PERMIT: 10020283
 ADD: 521 21ST ST.
 CONT: AYA SOLUTIONS INC.
 TEL: (305)792-6720
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S).
  
 REST ROOM GRAB BARS:
 11-4.17.6 GRAB BARS. GRAB BARS COMPLYING WITH THE
 LENGTH AND POSITIONING SHOWN IN FIGURES 30(A), 30(B),
 30(C), AND 30(D) SHALL BE PROVIDED. GRAB BARS MAY BE
 MOUNTED WITH ANY DESIRED METHOD AS LONG AS THEY HAVE A
 GRIPPING SURFACE AT THE LOCATIONS SHOWN AND DO NOT
 OBSTRUCT THE REQUIRED CLEAR FLOOR AREA. GRAB BARS SHALL
 COMPLY WITH SECTION 11-4.26.
  
 11-4.26 HANDRAILS, GRAB BARS, AND TUB AND SHOWER SEATS.
  
 11-4.26.1 GENERAL. ALL HANDRAILS, GRAB BARS, AND TUB
 AND SHOWER SEATS REQUIRED TO BE ACCESSIBLE BY SECTION
 11-4.1, 11-4.8, 11-4.9, 11-4.16, 11-4.17, 11-4.20 OR
 11-4.21 SHALL COMPLY WITH SECTION 11-4.26.
  
 11-4.26.2 SIZE AND SPACING OF GRAB BARS AND HANDRAILS.
 THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A
 HANDRAIL OR GRAB BAR SHALL BE 11/4 INCHES TO 11/2
 INCHES (32 MM TO 38 MM), OR THE SHAPE SHALL PROVIDE AN
 EQUIVALENT GRIPPING SURFACE. IF HANDRAILS OR GRAB BARS
 ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN THE
 WALL AND THE GRAB BAR SHALL BE 11/2 INCHES (38 MM) [SEE
 FIGURE 39(A), FIGURE 39(B), FIGURE 39(C), AND FIGURE
 39(E)]. HANDRAILS MAY BE LOCATED IN A RECESS IF THE
 RECESS IS A MAXIMUM OF 3 INCHES (76 MM) DEEP AND
 EXTENDS AT LEAST 18 INCHES (455 MM) ABOVE THE TOP OF
 THE RAIL [SEE FIGURE 39(D)].
  
 11-4.26.3 STRUCTURAL STRENGTH. THE STRUCTURAL STRENGTH
 OF GRAB BARS, TUB AND SHOWER SEATS, FASTENERS AND
 MOUNTING DEVICES SHALL MEET THE FOLLOWING
 SPECIFICATION:
  
 (1) BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE
 MAXIMUM BENDING MOMENT FROM THE APPLICATION OF 250 LBF
 (1112 N) SHALL BE LESS THAN THE ALLOWABLE STRESS FOR
 THE MATERIAL OF THE GRAB BAR OR SEAT.
  
 (2) SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE
 APPLICATION OF 250 LBF (1112 N) SHALL BE LESS THAN THE
 ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE GRAB BAR
 OR SEAT. IF THE CONNECTION BETWEEN THE GRAB BAR OR SEAT
 AND ITS MOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED
 TO BE FULLY RESTRAINED, THEN DIRECT AND TORSIONAL SHEAR
 STRESSES SHALL BE TOTALED FOR THE COMBINED SHEAR
 STRESS, WHICH SHALL NOT EXCEED THE ALLOWABLE SHEAR
 STRESS.
  
 (3) SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING
 DEVICE FROM THE APPLICATION OF 250 LBF (1112 N) SHALL
 BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER THE
 FASTENER OR MOUNTING DEVICE OR THE SUPPORTING
 STRUCTURE, WHICHEVER IS THE SMALLER ALLOWABLE LOAD.
  
 (4) TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT
 TENSION FORCE OF 250 LBF (1112 N) PLUS THE MAXIMUM
 MOMENT FROM THE APPLICATION OF 250 LBF (1112N) SHALL BE
 LESS THAN THE ALLOWABLE WITHDRAWAL LOAD BETWEEN THE
 FASTENER AND THE SUPPORTING STRUCTURE.
  
 (5) GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-02-23 Cont ID  
Sent By btrobaug Date 2010-02-23 Time 12:36 Rev Time 0.00
Received By btrobaug Date 2010-02-23 Time 12:35 Sent To  
Notes
2010-02-23 12:35:44ELECTRICAL PERMIT REQUIRED./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-02-24 Cont ID  
Sent By jwitmer Date 2010-02-24 Time 11:52 Rev Time 0.00
Received By jwitmer Date 2010-02-11 Time 15:22 Sent To  
Notes
2010-02-16 15:23:04B--14

Review Stop P PLUMBING
Rev No 1 Status N Date 2010-02-22 Cont ID  
Sent By kstevens Date 2010-02-22 Time 08:55 Rev Time 0.00
Received By kstevens Date 2010-02-18 Time 16:52 Sent To  
Notes
2010-02-22 08:55:55PLUMBING PERMIT REQUIRED.