| Plan Review Stops For Permit 10020203 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-03-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-03-18 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-03-18 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2010-03-18 16:39:58 | ESFR SPRINKLERS PER CONTRACTOR | | | FRP AT TOILETS & URINALS PER CONTRACTOR PER FBC1210 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-03-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-03-03 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-03-03 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2010-03-03 15:57:51 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS | | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. PLEASE PROVIDE RACK HEIGHT AND DISTANCE BETWEEN | | | RACKS, FBC106, FBC1005, FBC903. | | | | | | 2. SPECIFY INTERIOR FINISH CLASSIFICATION FBC803. | | | | | | 3. REFERENCE IS MADE TO DOOR RATINGS BUT NONE | | | SPECIFIED, FBC715. | | | | | | 4. BREAK ROOM SINK TO BE ACCESSIBLE; PLEASE PROVIDE | | | DETAILS FBC11-4.24. THE BASE IS SHOWN CONTINUOUS; | | | PLEASE SHOW HOW THIS COMPLIES WITH THE REQUIREMENTS OF | | | FBC11-4.24. | | | | | | 5. SEE FBC TABLE 1004.1 AND EXPLAIN OCCUPANT LOAD. F1 | | | IS DECLARED AS OCCUPANCY CLASSIFICATION, BUT 500 SF PER | | | PERSON WAS CALCULATED. THIS IS FOR WAREHOUSE SPACE; | | | MANUFACTURING AREAS ARE TO BE 200SF PER PERSON, | | | STORAGE/STOCK/SHIPPING AREAS ARE TO BE 300 SF PER | | | PERSON. IF THIS IS A DISTRIBUTION CENTER, IT APPEARS | | | THAT AT A MINIMUM 300SF PER PERSON SHOULD BE USED TO | | | CALCULATE OCCUPANT LOAD. | | | | | | 6. FBC1210, SEE REQUIREMENT FOR WALL FINISH | | | (BATHROOMS). | | | | | | 7. FIRE SPRINKLER PLANS (AT MINIMUM, HEAD LAYOUT) | | | REQUIRED PRIOR TO PERMIT ISSUANCE PER | | | FBC*106.3.5.1.1(5), FS553.79 (2). WILL THIS BE APPLIED | | | FOR PRIOR TO PERMIT ISSUANCE? | | | | | | 8. PLEASE CHECK ENERGY CALCS. NO DOORS SHOWN (3 DOORS | | | IN COMMON WALL SHOWN), R21 SHOWN FOR ROOF (PLEASE SHOW | | | WHERE ACOUSTIC CEILING CAN BE USED; R19 IS SHOWN ON | | | SHELL). CONFIRM THAT OTHER ITEMS ARE ACCURATE. | | | | | | 9. VALUATION HAS BEEN ADJUSTED PER ICC VALUATION | | | TABLES, FEBRUARY 2010. AT TIME OF SHELL CONSTRUCTION, | | | THE OWNER PROVIDED A VALUE OF APPROXIMATELY $55.72 PER | | | SQ FT. ($3,082,427 FOR 55,312 SF). BASED ON ICC TABLES, | | | THE VALUE OF OFFICE SPACE CONSTRUCTION IS $122.71, F1 | | | IS $69.92. THE VALUE HAS BEEN ADJUSTED TO A TOTAL OF | | | $1,845,881 LESS CREDIT FOR AMOUNT PAID ON THIS PORTION | | | OF THE SHELL ($1,350,122). TOTAL VALUATION $495,759. | | | PLEASE CONTACT ME IF YOU WISH TO DISCUSS. | | | | | | IF YOU WISH TO DISCUSS ANY OF THE ABOVE ITEMS, PLEASE | | | DO NOT HESITATE TO CONTACT ME AT YOUR CONVENIENCE. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2010-03-23 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-03-23 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-03-23 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2010-03-23 11:57:47 | SEE APPROVAL ON PLANS BY DOUG WISE |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2010-02-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-02-23 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-02-23 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2010-02-23 10:43:11 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2007 FLORIDA BUILDING CODE, 2009 REVISIONS, 2008 | | | NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING. | | | | | | 1} 13-415.AB.5 INTERIOR LIGHTING POWER, SCOPE. THE | | | INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING OR A | | | SEPARATELY METERED OR PERMITTED PORTION OF A BUILDING | | | SHALL BE DETERMINED BY THE SPACE-BY-SPACE METHOD | | | DESCRIBED IN SECTION 13-415.B.1. TRADE-OFFS OF INTERIOR | | | LIGHTING POWER ALLOWANCE AMONG PORTIONS OF THE BUILDING | | | FOR WHICH A DIFFERENT METHOD OF CALCULATION HAS BEEN | | | USED ARE NOT PERMITTED. THE INSTALLED INTERIOR LIGHTING | | | POWER IDENTIFIED IN ACCORDANCE WITH SECTION | | | 13-415.AB.5.1 SHALL NOT EXCEED THE INTERIOR LIGHTING | | | POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH | | | SECTION13-415.B.1*** SHOW COMPLIANCE ON THE PLAN. THIS | | | CAN BE DEMONSTRATED ON THE PLANS INDICATING THE | | | WATTAGES OF THE LUMINAIRES CHOSEN FOR THE PROJECT | | | CONFORM TO THE DENSITY REQUIREMENTS. INDICATE WATTAGES | | | ON THE FIXTURE SCHEDULE TO CORRELATE WITH THE ONES IN | | | THE CALCULATIONS. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2010-03-22 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-03-22 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-03-22 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2010-03-22 13:54:54 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED; PLAN SHEETS A-1, A-2, A-3, A-5, A-7, | | | E1, AND E3 WERE STAMPED, INITIALED, AND DATED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2010-03-01 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-03-01 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-03-01 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2010-03-01 13:23:28 | *****DENIED***** | | | | | | | | | 1. THE ACTUAL PROJECT SITE ADDRESS SHALL BE INCLUDED ON | | | THE COVER SHEET OF ANY SUBMITTALS AND IN THE TITLE | | | BLOCK OF EACH SUBMITTED PLAN SHEET. | | | | | | 2. ARE THERE MORE THAN ONE BUILDING USING THE SAME | | | NUMERICAL ADDRESS DESIGNATION? THE USE OF BUILDING | | | NUMBERS SHALL NOT BE LISTED UNLESS THERE ARE MORE THAN | | | ONE BUILDING USING THE SAME NUMERICAL ADDRESS. | | | | | | 3. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241 - 2004 | | | EDITION. | | | | | | 4. NFPA 101, LIFE SAFETY CODE, 2006 EDITION SHALL BE | | | REFERENCED. | | | | | | 5. SPECIFY THE INTERIOR FINISH MATERIALS FOR THE WALLS | | | AND CEILINGS IN TERMS OF CLASS A, CLASS B, OR CLASS C. | | | | | | 6. LIST THE RATING FOR ALL FIRE-RATED DOORS. | | | | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE/HOW EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-03-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-03-09 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-03-09 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-03-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-03-03 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-02-08 |
Time |
16:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2010-03-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-03-03 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-03-03 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2010-03-03 15:28:56 | PR 08005359 CHECKED BY GWEN - NO IMPACT FEES REQUIRED | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2010-03-23 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2010-03-23 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2010-03-23 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2010-03-23 10:22:36 | NEW SHEETS SUBMITTED, PROVISOS WERE NOT ADDRESSED. | | | | | | **PROVISO** | | | | | | 1. PROVIDE MANUFACTURER'S DATA FOR WIND RESISTANCE | | | CAPABILITIES OF RTU AND ROOF EXHAUST FAN. ALSO PROVIDE | | | INSTALLATION DETAIL FOR EXHAUST FAN. FBC-M 301.12. | | | | | | 2. EXHAUST FANS EF-1 AND EF-3 ARE REQUIRED TO PROVIDE | | | MINIMUM 100 CFM EACH PER ASHRAE 62.1 TABLE 6-4. | | | | | | 3. RETURN AIR TRANSFER DUCTS IN TOOMS 102 AND 110 ARE | | | TOO SMALL TO MEET THE BALANCED RETURN AIR EXCEPTIONS | | | UNDER FBC-M 601.4. | | | | | | REVISE PLANS AND RESUBMIT ACCORDINGLY PRIOR TO | | | INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2010-03-02 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2010-03-02 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2010-03-02 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2010-03-02 11:03:00 | **PROVISO** | | | | | | 1. PROVIDE MANUFACTURER'S DATA FOR WIND RESISTANCE | | | CAPABILITIES OF RTU AND ROOF EXHAUST FAN. ALSO PROVIDE | | | INSTALLATION DETAIL FOR EXHAUST FAN. FBC-M 301.12. | | | | | | 2. EXHAUST FANS EF-1 AND EF-3 ARE REQUIRED TO PROVIDE | | | MINIMUM 100 CFM EACH PER ASHRAE 62.1 TABLE 6-4. | | | | | | 3. RETURN AIR TRANSFER DUCTS IN TOOMS 102 AND 110 ARE | | | TOO SMALL TO MEET THE BALANCED RETURN AIR EXCEPTIONS | | | UNDER FBC-M 601.4. | | | | | | REVISE PLANS AND RESUBMIT ACCORDINGLY PRIOR TO | | | INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2010-03-22 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-03-22 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-03-22 |
Time |
12:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2010-02-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2010-02-18 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2010-02-17 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2010-02-18 13:55:48 | DENIED | | | REFERENCE: | | | FBC-2007 PLUMBING | | | FBC-2007 BUILDING | | | FBC-2007 CHAPTER 11 | | | | | | 1. PER TABLE 403.1 TWO DRINKING FOUNTAINS ARE REQUIRED. | | | (ONE FOR BUSINESS OCCUPANCY & ONE FOR STORAGE | | | OCCUPANCY). A HI/LOW DRINKING FOUNTAIN IS CONSIDERED | | | ONE FIXTURE AS IT HAS ONLY ONE SUPPLY & ONE TRAP. | | | SECTION 1002.1. (ALSO SEE SECTION 410.1). | | | | | | 2. SUBMIT A DETAIL FOR THE BREAK ROOM SINK SHOWING | | | COMPLIANCE WITH SECTION 11-4.24 WITH ALL SUBSECTIONS. | | | SUBMIT AN ELEVATION SHOWING THE FOLLOWING: | | | A. 11-4.24.2 HEIGHT | | | B. 11-4.24.3 KNEE CLEARANCE | | | C. 11-4.24.4 SINK DEPTH | | | D. 11-4.24.5 CLEAR FLOOR SPACE (FORWARD APPROACH | | | REQUIRED - CABINET DOORS NOT APPROVED) | | | E. 11-4.24.6 EXPOSED PIPES & SURFACES | | | F. 11-4.24.7 FAUCETS | | | | | | 3. SHT A-3 PER SECTION 1210.2 OF THE BUILDING CODE, | | | WALLS WITHIN 2 FEET OF URINALS & WATER CLOSETS SHALL | | | HAVE A SMOOTH, HARD, NONABSORBENT SURFACE TO A HEIGHT | | | UP TO 4 FEET ABOVE THE FLOOR. PAINTED WRB DOES NOT | | | COMPLY WITH THE REQUIREMENT FOR A HARD SURFACE. | | | | | | 4. SHTS P1 FLOOR PLAN AND P3 SANT RISER DIAGRAM. THE | | | BREAK ROOM SINK SHALL NOT DRAIN THROUGH THE WET VENT | | | FOR THE TOILET ROOM FIXTURES. SECTION 909.1. THE | | | FIXTURE SHALL DISCHARGE DOWNSTREAM OF THE TOILET ROOM | | | FIXTURES. | | | | | | 5. SHT P3 WATER ISOMETRIC RISER DIAGRAM. AIR CHAMBERS | | | ARE NOT APPROVED. PLEASE DELETE. THE WATER HAMMER | | | ARRESTOR LOCATED IN THE CEILING ABOVE THE DRINKING | | | FOUNTAIN SHALL BE LOCATED NEAR THE FIXTURE IN AN | | | "EFFECTIVE RANGE". PDI-WH 201. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2010-03-16 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2010-03-16 |
Time |
13:56 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2010-03-16 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2010-03-16 13:58:35 | PASSED W/PROVISO | | | | | | SUBMIT REVISED TRAFFIC EQUIVILANCY LETTER PRIOR TO C.O. | | | IF PERMIT IS ISSUED PRIOR TO SUBMITTAL THEN LETTER | | | SHALL BE A REVISION. IF PERMIT IS NOT ISSUED PRIOR TO | | | SUBMITTAL THEN LETTER SHALL BE A RESUBMITTAL. | | | | | | CONTACT ERIC SCHNEIDER (561) 822-1446. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2010-02-16 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2010-02-16 |
Time |
10:29 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2010-02-16 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2010-02-16 10:42:16 | FAILED | | | | | | 1) THE PLANS COMPLY WITH ZONING REQUIREMENTS. THE | | | INFORMATION TO SATISFY THE TRAFFIC CONDITION IN #2 | | | BELOW HAS NOT BEEN PROVIDED. ONCE THE INFORMATION IS | | | SUFFICIENTLY PROVIDED, ZONING WILL CHANGE TO A "PASS" | | | STATUS. | | | | | | 2) PER ORDINANCE NO. 3987-06: | | | | | | A. A USE CHART SHALL BE SUBMITTED TO THE PLANNING AND | | | ZONING AND CONSTRUCTION SERVICES DEPARTMENTS CONCURRENT | | | WITH ALL BUILDING PERMIT AND/OR OCCUPATIONAL LICENSE | | | APPLICATIONS STATING THE SQUARE FOOTAGE DEVOTED TO THE | | | USES WITHIN BUILDINGS 1, 2 AND 3. THE SPECIFIC SQUARE | | | FOOTAGE USE WITHIN EACH BUILDING MAY NOT EXCEED THE | | | ALLOWANCES OUTLINED IN THE BUILDING USE SQUARE FOOTAGE | | | TABLE (BELOW FOR BUILDING #1), UNLESS THE PROPERTY | | | OWNER PROVIDES A TRAFFIC EQUIVALENCY STATEMENT, | | | PREPARED BY A LICENSED TRAFFIC ENGINEER, DEMONSTRATING | | | THAT THE APPROVED TRAFFIC CONCURRENCY FOR THE PROJECT | | | IS NOT EXCEEDED. | | | | | | USE MAXIMUM SQUARE FOOTAGE | | | OFFICE/SHOWROOM 13,607 | | | INDUSTRIAL 8,164 | | | WHOLESALE 8,164 | | | WAREHOUSE 24,957 | | | STORAGE MEZZANINE 13,760 | | | | | | | | | B. A TRAFFIC STATEMENT, PREPARED BY A LICENSED TRAFFIC | | | ENGINEER, SHALL BE SUBMITTED TO THE PLANNING AND ZONING | | | AND CONSTRUCTION SERVICES DEPARTMENTS CONCURRENT WITH | | | ALL BUILDING PERMIT APPLICATIONS OUTLINING THE NUMBER | | | OF DAILY TRIPS, AM TRIPS AND PM TRIPS GENERATED FOR | | | EACH USE AND ITS SQUARE FOOTAGE FOR EACH BUILDING. THE | | | TRAFFIC STATEMENT SHALL INCLUDE THE TRIPS ASSOCIATED | | | WITH THE SPECIFIC USE AND A CUMULATIVE TABLE FOR ALL OF | | | THE USES APPROVED IN THE PREMIER PARK OF COMMERCE CPD. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | |
|
|