Plan Review Details - Permit 10020117
Plan Review Stops For Permit 10020117
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-03-10 Cont ID  
Sent By jgomez Date 2010-03-10 Time 16:31 Rev Time 0.00
Received By jgomez Date 2010-03-10 Time 15:49 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-02-09 Cont ID  
Sent By jgomez Date 2010-02-09 Time 16:26 Rev Time 0.00
Received By jgomez Date 2010-02-09 Time 16:25 Sent To  
Notes
2010-02-09 16:43:16RESIDENTIAL (R3) RENOVATION, BUILDING REVIEW CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- REVISE WIND LOAD DATA. ACCORDING TO SEC.
 R301.2.1.4.3 OF 2009 REVISIONS TO THE 2007 FLORIDA
 RESIDENTIAL CODE, THIS BUILDING IS LOCATED ON EXPOSURE
 "C" NOT "B". REVISE AS REQUIRED.
 ALSO, REVISE THE DESIGN PRESSURES AS REQUIRED.
  
 2- PROVIDE COMPLETE DETAILS ANS SPECIFICATIONS FOR THE
 CHIMNEY CONSTRUCTION. SPECIFY ALL FRAMING MEMBERS AND
 ALL CONNECTORS A TOP, BOTTOM AND ATTACHMENT TO THE
 EXISTING ROOF FRAMING SYSTEM TO VERIFY COMPLIANCE WITH
 THE DESIGN PRESSURES OF SEC. R301 OF 2007 FLORIDA
 RESIDENTIAL CODE. SECTION-CHIMNEY DOESN'T PROVIDE
 SPECIFICATIONS FOR HURRICANE STRAPS TO BE USED. NOTE
 STATING "PROVIDE GALV. METAL STRAP CONNECTORS FOR WIND
 LOADS 140MPH" IS NOT ENOUGH INFORMATION. ARCHITECT OF
 RECORD NEED TO SPECIFY ALL CONNECTORS REQUIRED TO
 RESIST ALL CALCULATED LOADS.
  
 3- PROVIDE COMPLETE SPECIFICATIONS/DETAILS FOR UL
 APPROVED PREFABRICATED FIREPLACE AND CHIMNEY TO BE
 INSTALLED AS REQUIRED BY SECTIONS R1004 AND R1005 OF
 2007 FLORIDA RESIDENTIAL CODE.
  
 4- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTES.
 NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK UP.
  
 JULIO GOMEZ
 COMBINATION COMMERCIAL PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-03-10 Cont ID  
Sent By btrobaug Date 2010-03-10 Time 15:34 Rev Time 0.00
Received By btrobaug Date 2010-03-10 Time 15:34 Sent To B
Notes
2010-03-10 15:34:35TO JULIO./WRT.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-02-17 Cont ID  
Sent By btrobaug Date 2010-02-17 Time 08:57 Rev Time 0.00
Received By btrobaug Date 2010-02-17 Time 08:49 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-03-08 Cont ID  
Sent By btrobaug Date 2010-02-17 Time 15:52 Rev Time  
Received By jgomez Date 2010-02-08 Time 13:49 Sent To  
Notes
2010-02-08 13:49:36R2

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2010-03-10 Cont ID  
Sent By jgomez Date 2010-03-10 Time 15:49 Rev Time 0.00
Received By jgomez Date 2010-03-10 Time 15:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2010-03-08 Cont ID  
Sent By jgomez Date 2010-03-08 Time 15:53 Rev Time 0.00
Received By jgomez Date 2010-03-08 Time 15:53 Sent To  
Notes
2010-03-08 16:37:33RESIDENTIAL (R3) RENOVATION, MECHANICAL REVIEW.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- PROVIDE COMPLETE SPECIFICATIONS FOR FACTORY-BUILT
 FIREPLACE AS REQUIRED BY SEC. 805 OF 2007 MECHANICAL
 CODE. CHIMNEYS NEED TO BE LISTED AND COMPLY WITH THE
 REQUIREMENTS OF UL 127.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop Z ZONING
Rev No 1 Status N Date 2010-02-11 Cont ID  
Sent By kdfreema Date 2010-02-11 Time 08:43 Rev Time 0.00
Received By kdfreema Date 2010-02-11 Time 08:43 Sent To  
Notes
***NONE***