2010-02-24 10:26:08****PROVISO****
 ****ISSUED AT CONTRACTOR'S RISK****
 ***REVISION REQUIRED PRIOR TO FIRST INSPECTION***
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. REVISE EXPOSURE CATEGORY OR EXPLAIN RATIONALE FOR
 EXPOSURE B. FBC1609, FBC R301.2.1.4. NOTE THAT THE CODE
 CHANGED EFFECTIVE MARCH 1, 2009.
  
 EXPOSURE B PLANS SUBMITTED. PLEASE SEE FBC R301.2.1.4.
 ALSO SEE THE ENGINEERING SUBMITTED, SHEET 3: EXPOSURE C
 INCLUDES A SITE WHICH HAS OPEN TERRAIN WITH SCATTERED
 OBSTRUCTIONS EXTENDING MORE THAN 1500 FEET FROM THE
 BUILDING SITE IN ANY QUADRANT. THIS PARCEL IS LOCATED
 ONE LOT FROM A PRESERVE; THEREFORE IT APPEARS THAT THIS
 WOULD BE CONSIDERED EXPOSURE C. IF THE ENGINEER WOULD
 LIKE TO PROVIDE A JUSTIFICATION FOR HIS RATIONALE FOR
 EXPOSURE B, PLEASE SUBMIT AS REQUESTED. A STATEMENT WAS
 HANDWRITTEN ON A COPY OF THE CODE (NOT INCLUDED IN THE
 ENGINEERING) WHICH STATES THAT THIS PARCEL IS 230 FEET
 FROM THE WATER, BUT THIS DOES NOT ADDRESS THE COMMENT -
 THE CODE REFERENCED CIRCLED IS RELATED TO THE
 REQUIREMENT FOR INCREASED ROOF UPLIFT DESIGN LOADS. THE
 CODE CIRCLED STATES THAT "EXPOSURE C SHALL APPLY FOR
 ALL CASES WHERE EXPOSURE B DOES NOT APPLY"; PLEASE SHOW
 HOW EXPOSURE B APPLIES TO THIS JOB BASED ON THE
 DEFINITION. THE RATIONALE FOR EXPOSURE B IS TO BE
 PREPARED BY THE ENGINEER.
  
 THE AAF WEBSITE HAS POSTED A DRAFT COMMENTARY ON THIS
 ISSUE WHICH YOU MAY FIND HELPFUL.
  
 THIS PERMIT IS ISSUED WITH PROVISO THAT EITHER NEW
 ENGINEERING BE SUBMITTED WITH EXPOSURE C CRITERIA OR
 RATIONALE FOR EXPOSURE B BE PROVIDED BY ENGINEER OF
 RECORD WHO IS TAKING RESPONSIBILITY FOR THE DESIGN.
 CONTRACTOR ASSUMES FULL RISK FOR WORK PERFORMED PRIOR
 TO ACCEPTANCE OF EXPOSURE B CRITERIA.
  
 2. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS, FS471.
  
 DOCUMENTS SUBMITTED ARE SEALED BUT INCLUDE A PHOTOCOPY
 SIGNATURE. PLEASE PROVIDE DOCUMENTS IN COMPLIANCE WITH
 THE FLORIDA STATUTE OR ADVISE AS TO ANY CHANGES IN FBPE
 POLICY.
  
  
 PLANS HAVE BEEN RETAINED BUT NOT ISSUED AS A PART OF
 THIS PERMIT. ENGINEERED PLANS REQUIRED PRIOR TO FIRST
 INSPECTION.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-01-27 Cont ID  
Sent By shill Date 2010-01-27 Time 11:16 Rev Time 0.00
Received By shill Date 2010-01-27 Time 11:07 Sent To  
Notes
2010-01-27 11:23:42****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. REVISE EXPOSURE CATEGORY OR EXPLAIN RATIONALE FOR
 EXPOSURE B. FBC1609, FBC R301.2.1.4. NOTE THAT THE CODE
 CHANGED EFFECTIVE MARCH 1, 2009.
  
 2. THE MARKINGS ON THE DOCUMENTS SUBMITTED HAVE MADE
 SOME OF THE TEXT ILLEGIBLE (HIGHLIGHTER OVER PHOTOCOPY
 INK WHICH SMEARED). PLEASE PROVIDE ENTIRELY LEGIBLE
 DOCUMENTS WHICH WILL REMAIN LEGIBLE AFTER SCANNING.
 NOTE THAT HIGHLIGHTER DOES NOT APPEAR, SO WHILE IT MAY
 BE HELPFUL TO ADD HIGHLIGHTER TO ASSIST IN INSPECTIONS
 AND REVIEW, INK SHOULD BE USED TO PERMANENTLY NOTE
 DETAILS WHICH DEMONSTRATE CODE COMPLIANCE FOR THIS
 PROJECT.
  
 3. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS, FS471.
  
 4. THE AAF GUIDE HAS BEEN INCORPORATED INTO THE FLORIDA
 BUILDING CODE PER FBC R301.2.1.1.1; THE DOCUMENT WHICH
 WAS USED TO CREATE THIS PERMIT PACKAGE IS NOT REFERRED
 TO IN THE FBC. IF YOU DISAGREE, PLEASE ADVISE AS TO
 CODE SECTION. SEE FBC R301.2.1.1, DESIGN CRITERIA, FOR
 ACCEPTABLE DESIGN METHODS. IF A PRESCRIPTIVE METHOD
 LISTED IS NOT USED FOR DESIGN, AND PLANS ARE NOT SIGNED
 AND SEALED, DESIGN PROPOSED IS TO BE SUPPORTED WITH
 CALCULATIONS FOR ALL STRUCTURAL MEMBERS AND
 ATTACHMENTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-02-08 Cont ID  
Sent By dpalmer Date 2010-02-08 Time 13:56 Rev Time 0.00
Received By dpalmer Date 2010-02-08 Time 13:56 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-01-27 Cont ID  
Sent By shill Date 2010-01-27 Time 11:23 Rev Time 0.00
Received By shill Date 2010-01-19 Time 09:23 Sent To  
Notes
2010-01-19 09:23:24TO ZONING
  

Review Stop Z ZONING
Rev No 3 Status P Date 2010-03-29 Cont ID  
Sent By jroach Date 2010-03-29 Time 14:01 Rev Time 0.00
Received By jroach Date 2010-03-29 Time 14:01 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2010-02-16 Cont ID  
Sent By jroach Date 2010-02-16 Time 18:47 Rev Time 0.00
Received By jroach Date 2010-02-16 Time 18:47 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2010-01-25 Cont ID  
Sent By jroach Date 2010-01-25 Time 18:35 Rev Time 0.00
Received By jroach Date 2010-01-25 Time 18:35 Sent To B
Notes
2010-01-25 18:39:11ZONING PLAN REVIEW
  
 PERMIT NO.: 10010251
 ADDRESS: 8312 PINE CAY
 CONTRACTOR/CONTACT: MULLET???S ALUMINUM PRODUCTS
 TELEPHONE NO.: 941.371.3502
 SCOPE OF REVIEW: INSTALL SCREEN ENCLOSURE AT REAR OF
 PROPERTY AND ENCLOSE FRONT ENTRY.
  
 REVIEW STATUS: FAILED
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1) PLEASE PROVIDE THE SETBACK FROM THE REAR OF THE
 PROPOSED SCREEN ENCLOSURE TO THE REAR PROPERTY LINE.
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 PLANNING AND ZONING DEPARTMENT
 401 CLEMATIS STREET - P.O. BOX 3366
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1435
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.CITYOFWPB.COM
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved