Plan Review Details - Permit 10010055
| Plan Review Stops For Permit 10010055 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2010-01-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-01-20 |
Time |
10:09 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2010-01-19 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-01-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2010-01-21 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2010-01-21 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2010-01-21 16:56:53 | | | | ** PROVISO ** | | | | | | ** REVISE THE FOLLOWING BEFORE ROUGH. SUBMIT PLANS AND | | | BE SURE PLANS ARE ON-SITE FOR INSPECTION. | | | | | | | | | 1) NOTE: PLANS ARE REFERENCED TO THE 2005 NEC. ALL PER | | | ALL PROJECTS SUBMITTED FOR PERMIT AFTER OCTOBER 1ST, | | | 2009 IS UNDER THE 2008 NEC. | | | | | | 2) NOTE: RISER DOES INCLUDE A PANEL L1 HOWEVER NO PANEL | | | SCHEDULE FOR PANEL L WAS SUBMITTED. CAN NOT VERIFY SIZE | | | OF FEEDER AND OVER CURRENT PROTECTION TO L1. | | | 240.4,310.16,408.4 ETC | | | CAN NOT VERIFY ADJUSTED LOADS ON PANEL L. | | | 220,220.12,220.14,220.42,220.44 ETC. CONTINUOUS LOADS | | | PER 215.3,230.42 ETC | | | CAN NOT VERIFY TAPPED CONDUCTORS FROM TRANSFORMER | | | TERMINATING IN OVER CURRENT PROTECTION PER 240.21, AND | | | 408.36. PANEL L1 IS A MLO PANEL. | | | | | | 3) NOTE: ALL MINIMUM LEVELS FOR HORNS, STROBE FOR ADA | | | COMPLIANCE NEEDS TO BE SHOWN. FOR EXAMPLE: STATING | | | STROBES TO MEET ADA COMPLIANCE DOES NOT PROVIDE MINIMUM | | | INFORMATION FOR COMPLIANCE. THIS SHOULD STATE MINIMUM | | | CD OR CANDELA 75 OR WORDS TO THAT AFFECT. THE SAME FOR | | | SOUNDING DEVICES AND LOCATIONS FOR DB LEVELS. | | | ALTHOUGH THE FIRE ALARM WILL BE UNDER A SEPARATE PERMIT | | | THE BASE PLANS IS REQUIRED TO SHOWN BASE DESIGN INTENT. | | | | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2010-01-25 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-01-25 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-01-25 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2010-01-25 13:17:35 | *****APPROVED***** | | | | | | | | | PLAN SHEETS A2, A-3, A-5, AND E-2 WERE STAMPED, | | | INITIALED, AND DATED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2010-01-25 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2010-01-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2010-01-11 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2010-01-25 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2010-01-25 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2010-01-25 |
Time |
16:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2010-01-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2010-01-12 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2010-01-12 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2010-01-12 08:48:49 | NO PLUMBING INDICATED OR SHOWN ON PLANS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2010-01-25 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2010-01-25 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2010-01-25 |
Time |
16:52 |
Sent To |
|
|
| Notes |
|
|
|