Plan Review Details - Permit 10010042
Plan Review Stops For Permit 10010042
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-01-21 Cont ID  
Sent By rmcdouga Date 2010-01-21 Time 16:49 Rev Time 0.00
Received By rmcdouga Date 2010-01-21 Time 16:49 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-01-07 Cont ID  
Sent By rmcdouga Date 2010-01-07 Time 11:53 Rev Time 0.00
Received By rmcdouga Date 2010-01-07 Time 09:41 Sent To  
Notes
2010-01-07 10:07:582007 FBC W/2009 REVISIONS
 CONVERT GARAGE TO BED AND BATH ROOMS
  
 DENIED BY BUILDING
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED. 561-233-5025
  
 2) THE BUILDING CODE SPECIFIED ON SHEET AO IS
 INCORRECT. THE 2007 FLORIDA BUILDING CODE WITH 2009
 REVISIONS IS THE APPLICABLE CODE.
  
 3) THE LEVEL OF ALTERATION SPECIFIED IS INCORRECT. THIS
 IS A LEVEL 2 ALTERATION PER FBC EXISTING BUILDING 404.1
  
 4) THE ENERGY CALCULATION FORMS THAT WERE SUBMITTED
 HAVE BEEN CHANGED BY THE 2009 REVISIONS TO THE 2007
 FBC. THE NEW FORM IS 1100B-08.
  
 5) SPECIFY THE INSULATION AT THE WALL BETWEEN THE
 STORAGE AREA AND THE CONDITIONED SPACE ON THE THE
 PLANS. FBC CHAPTER 13
  
 6) SPECIFY THE INSULATION FOR THE UNDER FLOOR SPACE ON
 THE PLANS. FBC CHAPTER 13
  
 7) SHOW COMPLIANCE WITH FBC R 408.2 FOR UNDER FLOOR
 VENTILATION OR R408.3 FOR UNVENTED CRAWL SPACE AND FBC
 R 408.4 FOR UNDER FLOOR ACCESS.
  
 8) THE WINDOW BUCK DETAIL ON SHEET S1 DOES NOT SPECIFY
 THE SPACING FOR THE FASTENERS. PLEASE SPECIFY SPACING
 ON THE PLANS.
  
 9) THE VALUE OF THE WORK ON THE APPLICATION IS TOO LOW.
 THE VALUE OF WORK IS TO INCLUDE ALL LABOR, MATERIAL,
 DESIGN COSTS, SUB-CONTRACTORS, PROFIT AND OVERHEAD AS
 WOULD BE CHARGED BY A CONTRACTOR FOR THE SCOPE OF WORK
 BEING PROPOSED. PLEASE ADJUST THE VALUE TO REFLECT ALL
 COSTS. FBC 108.3
  
 10) PLEASE RESPOND TO COMMENTS IN WRITING. PLEASE
 INDICATE HOW THE COMMENTS HAVE BEEN ADDRESSED IN THE
 RESPONSE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-01-20 Cont ID  
Sent By btrobaug Date 2010-01-20 Time 15:55 Rev Time 0.00
Received By btrobaug Date 2010-01-20 Time 15:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-01-12 Cont ID  
Sent By btrobaug Date 2010-01-12 Time 10:02 Rev Time 0.00
Received By btrobaug Date 2010-01-12 Time 09:32 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-01-19 Cont ID  
Sent By shill Date 2010-01-19 Time 10:33 Rev Time 0.00
Received By shill Date 2010-01-19 Time 10:33 Sent To  
Notes
2010-01-19 10:33:44R 11
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-01-12 Cont ID  
Sent By btrobaug Date 2010-01-12 Time 10:02 Rev Time 0.00
Received By btrobaug Date 2010-01-05 Time 08:52 Sent To  
Notes
2010-01-12 10:03:57HOLDING BIN(SMALL) UNDER "C"./WRT.
2010-01-06 08:56:17TO R2

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2010-01-21 Cont ID  
Sent By rmcdouga Date 2010-01-21 Time 16:49 Rev Time 0.00
Received By rmcdouga Date 2010-01-21 Time 16:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2010-01-21 Cont ID  
Sent By rmcdouga Date 2010-01-21 Time 15:53 Rev Time 0.00
Received By rmcdouga Date 2010-01-21 Time 15:53 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2010-01-07 Cont ID  
Sent By rmcdouga Date 2010-01-07 Time 09:40 Rev Time 0.00
Received By rmcdouga Date 2010-01-07 Time 09:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2010-01-21 Cont ID  
Sent By kstevens Date 2010-01-21 Time 08:29 Rev Time 0.00
Received By kstevens Date 2010-01-21 Time 08:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2010-01-06 Cont ID  
Sent By kstevens Date 2010-01-06 Time 09:16 Rev Time 0.00
Received By kstevens Date 2010-01-06 Time 09:16 Sent To  
Notes
2010-01-06 10:09:45DENIED
 REFERENCE:
 FBC-2007 RESIDENTIAL
 FBC-2007 EXISTING BUILDING
 FBC-2007 CHAPTER 1
  
 1. SHT A1 DETAIL 1 SHOWS THE NEW BATHROOM AS 6'4" WIDE.
 WITH THE SHOWER BEING 30" WIDE AND MOST W/C'S BEING 28"
 OR MORE IN LENGTH, THAT LEAVES ABOUT 18" CLEARANCE IN
 FRONT OF THE W/C. MINIMUM CLEARACE REQUIRED IS 21
 INCHES PER FIGURE R307.1.
  
 2. NOTE: SHT A1 DETAIL 1 SHOWS THE BATHROOM AS 4' DEEP.
 THE LAV AND W/C CLEARANCES SHALL COMPLY WITH FIGURE
 R307.1. NOT KNOWING THE MAKE AND MODEL OF THE BATHROOM
 FIXTURES, (W/C & LAV), THE CLEARANCES WILL BE REQUIRED
 TO BE MET AT FINAL INSPECTION.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2010-01-21 Cont ID  
Sent By kdfreema Date 2010-01-21 Time 11:50 Rev Time 0.00
Received By kdfreema Date 2010-01-21 Time 11:50 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2010-01-11 Cont ID  
Sent By kdfreema Date 2010-01-11 Time 10:57 Rev Time 0.00
Received By kdfreema Date 2010-01-11 Time 10:57 Sent To  
Notes
***NONE***