Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2010-01-13 Cont ID  
Sent By jgomez Date 2010-01-13 Time 11:01 Rev Time 0.00
Received By jgomez Date 2010-01-13 Time 11:01 Sent To PC
Notes
2010-01-13 11:04:19RECEIVE LETTER FROM CONTRACTOR (DAVID K. GRUBER)
 STATING THAT EXISTING WINDOWS ARE SINGLE HUNG WINDOWS
 AND THEY ARE REPLACING THEM WITH SINGLE HUNG WINDOWS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2010-01-12 Cont ID  
Sent By jgomez Date 2010-01-12 Time 13:50 Rev Time 0.00
Received By jgomez Date 2010-01-12 Time 13:54 Sent To  
Notes
2010-01-12 13:54:51REVISION SECOND CHECKLIST.
  
 1- PRODUCT APPROVALS SUBMITTED ARE FOR SINGLE HUNG
 WINDOWS AND FIXED WINDOWS. ORIGINAL PRODUCT APPROVALS
 AND PLANS SHOWED ONLY CASEMENT WINDOWS. NEED TO REVISE
 PLANS TO SHOW WINDOW SIZES TO VERIFY COMPLIANCE WITH
 THE EGRESS REQUIREMENTS OF SEC. R310 OF 2007 FLORIDA
 RESIDENTIAL CODE (COMMENT NOT ADDRESSED AT ALL).
 REVISED PLANS TO SHOW EXISTING BEDROOM WINDOWS SIZES
 AND PROPOSED WINDOW SIZES TO VERIFY COMPLIANCE WITH THE
 MINIMUM REQUIRED CLEAR OPENINGS.
 ***NOTE: A MAXIMUM OF 5% REDUCTION IN THE CLEAR OPENING
 DIMENSION WILL BE ALLOWED. SEC. 604.1 OF 2007 FLORIDA
 BUILDING CODE-EXISTING.
  
 2- WINDOW MULLION PRODUCT APPROVAL. CLEARLY MARK ON
 MULLION PRODUCT APPROVALS SPECIFIC MULLION SIZE AND
 ANCHORS TO BE USED TO VERIFY COMPLIANCE WITH THE DESIGN
 PRESSURES CALCULATED BY THE ENGINEER OF RECORD. SEC.
 R301 OF 2007 FLORIDA RESIDENTIAL CODE (COMMENT NOT
 ADDRESSED AT ALL).
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-01-05 Cont ID  
Sent By jgomez Date 2010-01-05 Time 13:57 Rev Time 0.00
Received By jgomez Date 2010-01-05 Time 13:57 Sent To PC
Notes
2010-01-05 14:05:57REVISION CHECKLIST.
  
 1- PRODUCT APPROVALS SUBMITTED ARE FOR SINGLE HUNG
 WINDOWS AND FIXED WINDOWS. ORIGINAL PRODUCT APPROVALS
 AND PLANS SHOWED ONLY CASEMENT WINDOWS. NEED TO REVISE
 PLANS TO SHOW WINDOW SIZES TO VERIFY COMPLIANCE WITH
 THE EGRESS REQUIREMENTS OF SEC. R310 OF 2007 FLORIDA
 RESIDENTIAL CODE.
  
 2- DESIGN PROFESSIONAL OF RECORD TO REVIEW AND APPROVE
 IN WRITING (NOT SIGNING AND SEALING) ALL PRODUCT
 APPROVALS PRIOR TO SUBMITTAL TO THIS OFFICE. SEC.
 106.3.3 CITY AMENDMENTS TO FBC.
  
 3- WINDOW MULLION PRODUCT APPROVAL. CLEARLY MARK ON
 MULLION PRODUCT APPROVALS SPECIFIC MULLION SIZE AND
 ANCHORS TO BE USED TO VERIFY COMPLIANCE WITH THE DESIGN
 PRESSURES CALCULATED BY THE ENGINEER OF RECORD. SEC.
 R301 OF 2007 FLORIDA RESIDENTIAL CODE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-01-12 Cont ID  
Sent By btrobaug Date 2010-01-12 Time 12:56 Rev Time 0.00
Received By btrobaug Date 2010-01-12 Time 12:56 Sent To B
Notes
2010-01-12 12:57:02TO JULIO./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-01-05 Cont ID  
Sent By jgomez Date 2010-01-05 Time 14:19 Rev Time 0.00
Received By jgomez Date 2010-01-04 Time 15:04 Sent To  
Notes
2010-01-04 15:04:20TO JG DESK
  